510(k) Report

510(k) · Cleared

Cleared

Bahadir Sterilization Trays

K131407510(k) AbbreviatedCleared Aug 12, 2014454-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bahadir USA Corp. · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories

Cleared on Aug 12, 2014 as substantially equivalent to K112090 (Bahadir USA Corp., 2012) and 3 other predicates after a 454-day review. Its family tree reaches back 7 generations to 2000. 1 later device descends from it.

Decided
Aug 12, 2014
Review
454 days
Class
Class II
Product code
KCT
Recalls
None
Predicates
4

Its longest line of descent runs back 7 generations to K991023 (2000). 15 ancestors in all, the oldest K792558 (1979). 1 later device descends from it, 1 citing it directly.

  1. Root · 7 generations backK991023 Steritite Perforated Bottom Rigid Reusable Sterilization Container…Case Medical, Inc. · 2000
  2. 6 generations backK012931 Genesis Sterrad Compatible Reusable Sterilization Container SystemAllegiance Healthcare Corp. · 2002
  3. 5 generations backK023614 Steritite Rigid Reusable Sterilization Container SystemCase Medical, Inc. · 2003 · Recalled
  4. 4 generations backK050570 Miltex Rigid Sterilization Container SystemMiltex, Inc. · 2005
  5. 3 generations backK091720 Sklarlite Rigid Sterilization Container SystemSklar Corp. · 2010
  6. 2 generations backK102146 Bahadir Sterilization TraysBahadir USA Corp. · 2010 · Recalled
  7. 1 generation backK112090 Bahadir Sterilization TraysBahadir USA Corp. · 2012 · Recalled
  8. This deviceK131407 Bahadir Sterilization TraysBahadir USA Corp. · 2014
  9. Descendant · cites it directly · 0 of its ownK233578 Bahadir Sterilization ContainersBahadir USA, LLC · 2024

Most influential descendants

Showing 1 of 1 · See all
  • K233578Bahadir Sterilization ContainersBahadir USA, LLC · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K991023Steritite Perforated Bottom Rigid Reusable Sterilization Container System with…Case Medical, Inc.2000—
−6K012931Genesis Sterrad Compatible Reusable Sterilization Container SystemAllegiance Healthcare Corp.2002—
−5K023614Steritite Rigid Reusable Sterilization Container SystemCase Medical, Inc.20031
−4K050570Miltex Rigid Sterilization Container SystemMiltex, Inc.2005—
−3K091720Sklarlite Rigid Sterilization Container SystemSklar Corp.2010—
−2K102146Bahadir Sterilization TraysBahadir USA Corp.20101
−1K112090Bahadir Sterilization TraysBahadir USA Corp.20121
0 (this device)K131407Bahadir Sterilization TraysBahadir USA Corp.2014—
+1K233578Bahadir Sterilization ContainersBahadir USA, LLC2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198710
199730
200310
200610
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K131407, 2000–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KCT device

  1. #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112090Bahadir Sterilization Trays
Summary page 6
…fication Name Sterilization Wraps, Trays, Containers Class II – KCT Regulation Number: 21 CFR 880.6850 Regulation Name: Sterilization Tray Predicate Devices Bahadir – K112090 Bahadir– K102146 Aesculap – K053389 Sklar – K091720 K131407 Intended Use:…
Bahadir USA Corp.20121
*K102146Bahadir Sterilization Trays
Summary page 6
…rilization Wraps, Trays, Containers Class II – KCT Regulation Number: 21 CFR 880.6850 Regulation Name: Sterilization Tray Predicate Devices Bahadir – K112090 Bahadir– K102146 Aesculap – K053389 Sklar – K091720 K131407 Intended Use: Intended for use…
Bahadir USA Corp.20101
*K053389Aesculap Sterilcontainer System
Summary page 6
…rays, Containers Class II – KCT Regulation Number: 21 CFR 880.6850 Regulation Name: Sterilization Tray Predicate Devices Bahadir – K112090 Bahadir– K102146 Aesculap – K053389 Sklar – K091720 K131407 Intended Use: Intended for use in hospitals and h…
Aesculap, Inc.2006—
*K091720Sklarlite Rigid Sterilization Container System
Summary page 6
…Class II – KCT Regulation Number: 21 CFR 880.6850 Regulation Name: Sterilization Tray Predicate Devices Bahadir – K112090 Bahadir– K102146 Aesculap – K053389 Sklar – K091720 K131407 Intended Use: Intended for use in hospitals and healthcare facili…
Sklar Corp.2010—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K233578Bahadir Sterilization ContainersBahadir USA, LLC20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 5 companies; a new generation was cleared every 2.2 years on median.
  • 4 of the 15 ancestors have a recall of any class.
  • Of its descendants, K233578 (Bahadir USA, LLC, 2024) has gone furthest, with 0 descendants of its own.

How does its category compare?

All KCT devices

KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · KCT

11in 2025

2007: 32008: 62009: 62010: 122011: 62012: 102013: 82014: 112015: 152016: 122017: 102018: 152019: 182020: 142021: 182022: 112023: 102024: 82025: 112026 (partial year): 9
2007high 18 (2019) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KCT

205in 2025

2007: 199 days median2008: 182 days median2009: 89 days median2010: 202 days median2011: 117 days median2012: 236 days median2013: 131 days median2014: 169 days median2015: 151 days median2016: 182 days median2017: 211 days median2018: 192 days median2019: 187 days median2020: 134 days median2021: 185 days median2022: 137 days median2023: 94 days median2024: 106 days median2025: 205 days median2026 (partial year): 122 days median
2007high 236 (2012) · low 89 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KCT

17in 2022

2010: 12011: 22013: 12014: 12016: 32017: 12021: 12022: 17
2007high 17 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KCT

50in 2025

2007: 22008: 82009: 52010: 32011: 32012: 22013: 62014: 52015: 62016: 162017: 32018: 222019: 152020: 662021: 262022: 82023: 302024: 182025: 50
2007high 66 (2020) · low 2 (2007)2025

MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007319902
2008618208
200968905
20101220213
2011611723
20121023602
2013813116
20141116915
20151515106
201612182316
20171021113
201815192022
201918187015
202014134066
202118185126
202211137178
20231094030
20248106018
202511205050
202691220—

What is it indicated for?

Intended for use in hospitals and healthcare facilities to contain other medical devices that are to be sterilized for Immediate Use and/or Pre Vacuum Sterilization. Pre Vacuum sterilized devices may be stored in protective storage (temperature, humidity, air filtration etc. controlled hospital storage room conditions) for up to 6 months provided integrity of container is not compromised. Bahadir Pre Vacuum sterilization containers may be stacked during…

Read the full statement (522 words)

Intended for use in hospitals and healthcare facilities to contain other medical devices that are to be sterilized for Immediate Use and/or Pre Vacuum Sterilization. Pre Vacuum sterilized devices may be stored in protective storage (temperature, humidity, air filtration etc. controlled hospital storage room conditions) for up to 6 months provided integrity of container is not compromised.

Bahadir Pre Vacuum sterilization containers may be stacked during storage, one on top of one another, the heavier container being on the bottom. Pre Vacuum sterilization containers may be stacked up to 18 inches during the sterilization process with no more than THREE containers as part of the 18” maximum configuration. Containers are marked as to their height to facilitate this process.

3 containers MAXIMUM can be stacked.

Stacked containers may not exceed a maximum of 18 inches

Immediate Use only intended for non-stacked configurations during the sterilization process.

The devices included in this submission are to be used with a pre-vacuum, three pulse standard cycle of 4 minutes at 270 degrees F with a dry time of 20 minutes or Immediate Use sterilization.

The devices (natural aluminum color containers with colored lids as follows: green, yellow/golden orange, red, deep black and natural aluminum) subject to this submission are as follows:

Flat Size Y310.05A Mini Size Y410.04A Dental Size Y510.04A

Flat Size Y310.08A Mini Size Y410.07A Dental Size Y510.06A

Flat Size Y311.08A Mini Size Y410.10A Dental Size Y510.08A

Mini Size Y411.04A Dental Size Y510.10A

Mini Size Y411.07A Dental Size Y510.13A

Mini Size Y411.10A Dental Size Y511.04A

Dental Size Y511.06A

Dental Size Y511.08A

Dental Size Y511.10A

Dental Size Y511.13A

Full size Y110.10W ¾ size Y210.10W ½ size Y310.10W

Full size Y111.10W ¾ size Y210.13W ½ size Y310.13W

Full size Y110.13W ¾ size Y210.15W ½ size Y310.15W

Full size Y111.13W ¾ size Y211.10W ½ size Y310.20W

Full size Y110.15W ¾ size Y211.13W ½ size Y310.26W

Full size Y111.15W ¾ size Y211.15W ½ size Y311.10W

Full size Y110.20W ½ size Y311.13W

Full size Y111.20W ½ size Y311.15W

Full size Y111.26W ½ size Y311.20W

Wide size Y110.62W ½ size Y311.26W

Wide size Y110.68W

Wide size Y111.62W

Wide size Y111.68W

The Containers have been validated for sterilization of instrument load weights shown below, and may include in this max load weight up to 2 instruments with lumens no smaller than 1 mm in diameter and no longer than 300 mm in length for the Full Size, ¾ Size, and Wide Body Containers, and no smaller than 1 mm in diameter and no longer than 200mm in length for the Half Size, Mini, Flat, & Dental Containers.

The maximum load weights for the Sterilization Containers which are the subject of this premarket notification are as follows:

Maximum Recommended Load (including basket and contents)

LBS.

Model Dimensions (mm)

580X280X100 24.75

580X280X135 24.75

1/1 Size

580X280X150 24.75

Container

580X280X200 24.75

580X280X260 24.75

465x280x100 12.5

3/4 Size

465x280x135 12.5

Container

465x280x150 12.5

285x280x100 9.25

1/2 Size 285x280x135 9.25

285x280x150 9.25

Container 285x280x200 9.25

285x280x260 9.25

600x400x120 24.75

Wide Body

Container 600x400x180 24.75

285x280x55 9.25

Flat

Container 285x280x85 9.25

300x140x40 6.0

Mini

300x140x70 6.0

Container 300x140x100 6.0

310x190x40 9.25

Dental

310x190x65 9.25

Container 310x190x130 9.25

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K131407: Bahadir Sterilization Trays.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K131407

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026