510(k) Report

510(k) · Cleared

Cleared

Mobis II ST Spinal Implant

K141405510(k) TraditionalCleared Sep 16, 2014111-day reviewClass II21 CFR 888.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Signus Medizintechnik GmbH · MAX Intervertebral Fusion Device With Bone Graft, Lumbar

Cleared on Sep 16, 2014 as substantially equivalent to K131372 (Signus Medizintechnik GmbH, 2013) and 3 other predicates after a 111-day review. Its family tree reaches back 9 generations to 1984. 461 later devices descend from it.

Decided
Sep 16, 2014
Review
111 days
Class
Class II
Product code
MAX
Recalls
None
Predicates
4

Its longest line of descent runs back 9 generations to K841189 (1984). 50 ancestors in all. 461 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2010: 1 other ancestor2008: 8 other ancestors2007: 6 other ancestors2012: 1 other ancestor2009: 2 other ancestors2002: 5 other ancestors2001: 8 other ancestors1999: 2 other ancestors1996: 2 other ancestors2005: 1 other ancestor2004: 3 other ancestors2003: 1 other ancestor2000: 1 other ancestor2024: 73 descendants cleared2015: 1 descendant cleared2016: 5 descendants cleared2017: 19 descendants cleared2018: 22 descendants cleared2019: 31 descendants cleared2020: 48 descendants cleared2026: 48 descendants cleared2023: 67 descendants cleared2021: 43 descendants cleared2022: 50 descendants cleared2025: 54 descendants clearedK841189 · Oec/Rezaian Spinal Fixator · Orthopedic Equipment Co., Inc. · 1984K990148 · Stackable Cage System · Depuy Motech Acromed · 1999K003043 · Surgical Titanium Mesh System · Depuyacromed · 2001×2: 2 generations cleared close together, K022793 (2003), K031757 (2003) K033109 · Ellys and Aurys Vertebral Body Replacements · Scient'X · 2004K043479 · MC+ Partial VBR · Ldr Spine USA · 2005K090064 · Eminent Spine Interbody Fusion System · Eminent Spine · 2009 · recalledK131372 · Mobis II · Signus Medizintechnik GmbH · 201319801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 2 other ancestors3 generations back: 13 other ancestors4 generations back: 6 other ancestors5 generations back: 6 other ancestors6 generations back: 9 other ancestors7 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 16 descendants3 generations forward: 70 descendants4 generations forward: 110 descendants5 generations forward: 117 descendants6 generations forward: 91 descendants7 generations forward: 38 descendants8 generations forward: 12 descendants9 generations forward: 3 descendants10 generations forward: 2 descendants K131372 · Mobis II · Signus Medizintechnik GmbH · 2013K090064 · Eminent Spine Interbody Fusion System · Eminent Spine · 2009 · recalledK043479 · MC+ Partial VBR · Ldr Spine USA · 2005K033109 · Ellys and Aurys Vertebral Body Replacements · Scient'X · 2004K031757 · Peek Tetris Spinal Implant · Signus Medical, LLC · 2003K022793 · Tetris Spinal Implant · Signus Medical, LLC · 2003K003043 · Surgical Titanium Mesh System · Depuyacromed · 2001K990148 · Stackable Cage System · Depuy Motech Acromed · 1999K841189 · Oec/Rezaian Spinal Fixator · Orthopedic Equipment Co., Inc. · 1984−50+5+10
  1. Root · 9 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
  2. 5 generations between
  3. 3 generations backK043479 MC+ Partial VBRLdr Spine USA · 2005
  4. 2 generations backK090064 Eminent Spine Interbody Fusion SystemEminent Spine · 2009 · Recalled
  5. 1 generation backK131372 Mobis IISignus Medizintechnik GmbH · 2013
  6. This deviceK141405 Mobis II ST Spinal ImplantSignus Medizintechnik GmbH · 2014
  7. Descendant · cites it directly · 459 of its ownK150481 Cascadia Interbody SystemK2m, Inc. · 2015 · Recalled
  8. Descendant · 2 generations on · 315 of its ownK160125 Cascadia Interbody SystemK2m · 2016
  9. Descendant · 2 generations on · 276 of its ownK163230 NuVasive Modulus XLIF Interbody SystemNu Vasive, Incorporated · 2017
  10. Descendant · 3 generations on · 227 of its ownK172123 NuVasive® Modulus XLIF Interbody SystemNu Vasive, Incorporated · 2017
  11. Descendant · 2 generations on · 169 of its ownK162264 Cascadia Interbody SystemK2m, Inc. · 2016
Show all 9 generations
  1. Root · 9 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
  2. 8 generations backK990148 Stackable Cage SystemDepuy Motech Acromed · 1999
  3. 7 generations backK003043 Surgical Titanium Mesh SystemDepuyacromed · 2001
  4. 6 generations backK022793 Tetris Spinal ImplantSignus Medical, LLC · 2003
  5. 5 generations backK031757 Peek Tetris Spinal ImplantSignus Medical, LLC · 2003
  6. 4 generations backK033109 Ellys and Aurys Vertebral Body ReplacementsScient'X · 2004
  7. 3 generations backK043479 MC+ Partial VBRLdr Spine USA · 2005
  8. 2 generations backK090064 Eminent Spine Interbody Fusion SystemEminent Spine · 2009 · Recalled
  9. 1 generation backK131372 Mobis IISignus Medizintechnik GmbH · 2013
  10. This deviceK141405 Mobis II ST Spinal ImplantSignus Medizintechnik GmbH · 2014

Showing 5 of 461 descendants. See all descendants

Descendants cleared per year

2015: 12016: 52017: 192018: 222019: 312020: 482021: 432022: 502023: 672024: 732025: 542026: 48
2015high 73 (2024) · low 1 (2015)2026

Most influential descendants

Showing 5 of 461 · See all
  • K150481Cascadia Interbody SystemK2m, Inc. · 2015 · cites it directly459descendants
  • K160125Cascadia Interbody SystemK2m · 2016 · 2 generations on315descendants
  • K163230NuVasive Modulus XLIF Interbody SystemNu Vasive, Incorporated · 2017 · 2 generations on276descendants
  • K172123NuVasive® Modulus XLIF Interbody SystemNu Vasive, Incorporated · 2017 · 3 generations on227descendants
  • K162264Cascadia Interbody SystemK2m, Inc. · 2016 · 2 generations on169descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K841189Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc.1984—
−8K990148Stackable Cage SystemDepuy Motech Acromed1999—
−7K003043Surgical Titanium Mesh SystemDepuyacromed2001—
−6K022793Tetris Spinal ImplantSignus Medical, LLC2003—
−5K031757Peek Tetris Spinal ImplantSignus Medical, LLC2003—
−4K033109Ellys and Aurys Vertebral Body ReplacementsScient'X2004—
−3K043479MC+ Partial VBRLdr Spine USA2005—
−2K090064Eminent Spine Interbody Fusion SystemEminent Spine20091
−1K131372Mobis IISignus Medizintechnik GmbH2013—
0 (this device)K141405Mobis II ST Spinal ImplantSignus Medizintechnik GmbH2014—
+1K150481Cascadia Interbody SystemK2m, Inc.20153
+2K160125Cascadia Interbody SystemK2m2016—
+2K163230NuVasive Modulus XLIF Interbody SystemNu Vasive, Incorporated2017—
+3K172123NuVasive® Modulus XLIF Interbody SystemNu Vasive, Incorporated2017—
+2K162264Cascadia Interbody SystemK2m, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
199920
200010
200180
200250
200310
200430
200510
200760
200880
200920
201010
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201510
201650
2017190
2018220
2019310
2020480
2021430
2022500
2023670
2024730
2025540
2026480
FIG. 1 — Lineage of K141405, 1984–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MAX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MAX device

  1. #1 K203714 NuVasive Thoracolumbar Interbody Systems…score 102.5 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K131372Mobis II
Summary page 5
…ct Code: MAX CFR section: 21 CFR section 888.3080 Device panel: Orthopedic Legally Marketed MOBIS® Spinal Implant (K131372) Predicate Device: T-PAL Spacer (K100089) Lucent Straight Cage (K071724/K081968)…
Signus Medizintechnik GmbH2013—
*K100089Synthes T-Pal Spacer
Summary page 5
…ection 888.3080 Device panel: Orthopedic Legally Marketed MOBIS® Spinal Implant (K131372) Predicate Device: T-PAL Spacer (K100089) Lucent Straight Cage (K071724/K081968) Submitter: SIGNUS Medizintechnik…
Synthes Spine20101
*K071724Lucent
Summary page 5
…Legally Marketed MOBIS® Spinal Implant (K131372) Predicate Device: T-PAL Spacer (K100089) Lucent Straight Cage (K071724/K081968) Submitter: SIGNUS Medizintechnik GmbH Industriestrasse 2…
Spinal Elements, Inc.2007—
*K081968Modification to Lucent
Summary page 5
…Legally Marketed MOBIS® Spinal Implant (K131372) Predicate Device: T-PAL Spacer (K100089) Lucent Straight Cage (K071724/K081968) Submitter: SIGNUS Medizintechnik GmbH Industriestrasse 2…
Spinal Elements, Inc.2008—

What descends from it? (461)

See all 461

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K150481Cascadia Interbody SystemK2m, Inc.2015459
K241438Signus Tetris™ St; Signus Tetris™ R StSignus Medizintechnik GmbH20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 8 companies; a new generation was cleared every 1.7 years on median.
  • 8 of the 50 ancestors have a recall of any class.
  • Of its descendants, K150481 (K2m, Inc., 2015) has gone furthest, with 459 descendants of its own.

How does its category compare?

All MAX devices

MAX Intervertebral Fusion Device With Bone Graft, Lumbar: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · MAX

29in 2025

2007: 72008: 352009: 312010: 292011: 492012: 482013: 582014: 582015: 532016: 642017: 762018: 642019: 602020: 562021: 532022: 412023: 302024: 382025: 292026 (partial year): 18
2007high 76 (2017) · low 7 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MAX

85in 2025

2007: 86 days median2008: 88 days median2009: 102 days median2010: 137 days median2011: 98 days median2012: 69 days median2013: 102 days median2014: 115 days median2015: 113 days median2016: 124 days median2017: 116 days median2018: 114 days median2019: 131 days median2020: 106 days median2021: 109 days median2022: 95 days median2023: 87 days median2024: 91 days median2025: 85 days median2026 (partial year): 95 days median
2007high 137 (2010) · low 69 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MAX

5in 2025

2008: 22009: 92011: 32012: 11, 1 Class I2014: 32015: 12016: 62017: 12018: 42019: 12022: 12024: 12025: 5
2007high 11 (2012) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · MAX

811in 2025

2007: 122008: 192009: 902010: 1542011: 2012012: 3272013: 3802014: 3662015: 5242016: 6472017: 5962018: 6162019: 6992020: 6402021: 6222022: 6182023: 5762024: 7292025: 811
2007high 811 (2025) · low 12 (2007)2025

MAUDE reports naming product code MAX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007786012
20083588219
200931102990
2010291370154
201149983201
2012486911 (1)327
2013581020380
2014581153366
2015531131524
2016641246647
2017761161596
2018641144616
2019601311699
2020561060640
2021531090622
202241951618
202330870576
202438911729
202529855811
202618950—

What is it indicated for?

The MOBIS®II ST Spinal Implant is indicated for intervertebral body spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2-S1. DDD is defined as discogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies. These DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). MOBIS®II ST Spinal Implants are to be…

Read the full statement (115 words)

The MOBIS®II ST Spinal Implant is indicated for intervertebral body spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2-S1. DDD is defined as discogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies. These DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). MOBIS®II ST Spinal Implants are to be used with autogenous bone graft and implanted via an open posterior or transforaminal approach. The MOBIS®II ST Spinal Implant is to be used with supplemental fixation. Patients should have at least six (6) months of non-operative treatment prior to treatment with an intervertebral cage.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K141405: Mobis II ST Spinal Implant.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141405

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026