CAVUX™ Cervical Cage

K161642510(k) TraditionalCleared Oct 7, 2016115-day reviewClass II21 CFR 888.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Providence Medical Technology, Inc. · ODP Intervertebral Fusion Device With Bone Graft, Cervical

Cleared on Oct 7, 2016 as substantially equivalent to K122801 (Providence Medical Technology, Inc., 2013) after a 115-day review. Its family tree reaches back 12 generations to 1984.

Decided
Oct 7, 2016
Review
115 days
Class
Class II
Product code
ODP
Recalls
None
Predicates
1

Its longest line of descent runs back 12 generations to K841189 (1984). 51 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 12 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
  2. 8 generations between
  3. 3 generations backK091088 LDR Spine Cervical Interbody Fusion SystemLdr Spine USA · 2009
  4. 2 generations backK111123 Varilift Cervical Interbody Fusion SystemWenzel Spine · 2011
  5. 1 generation backK122801 Providence Cervical CageProvidence Medical Technology, Inc. · 2013
  6. This deviceK161642 CAVUX™ Cervical CageProvidence Medical Technology, Inc. · 2016
Show all 12 generations
  1. Root · 12 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
  2. 11 generations backK990148 Stackable Cage SystemDepuy Motech Acromed · 1999
  3. 10 generations backK003043 Surgical Titanium Mesh SystemDepuyacromed · 2001
  4. 9 generations backK022793 Tetris Spinal ImplantSignus Medical, LLC · 2003
  5. 8 generations backK031757 Peek Tetris Spinal ImplantSignus Medical, LLC · 2003
  6. 7 generations backK033109 Ellys and Aurys Vertebral Body ReplacementsScient'X · 2004
  7. 6 generations backK043479 MC+ Partial VBRLdr Spine USA · 2005
  8. 5 generations backK080728 LDR Spine Roi-C ImplantLdr Spine USA · 2008
  9. 4 generations backK083857 LDR Spine Roi-C ImplantLdr Spine USA · 2009
  10. 3 generations backK091088 LDR Spine Cervical Interbody Fusion SystemLdr Spine USA · 2009
  11. 2 generations backK111123 Varilift Cervical Interbody Fusion SystemWenzel Spine · 2011
  12. 1 generation backK122801 Providence Cervical CageProvidence Medical Technology, Inc. · 2013
  13. This deviceK161642 CAVUX™ Cervical CageProvidence Medical Technology, Inc. · 2016
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K841189Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc.1984—
−11K990148Stackable Cage SystemDepuy Motech Acromed1999—
−10K003043Surgical Titanium Mesh SystemDepuyacromed2001—
−9K022793Tetris Spinal ImplantSignus Medical, LLC2003—
−8K031757Peek Tetris Spinal ImplantSignus Medical, LLC2003—
−7K033109Ellys and Aurys Vertebral Body ReplacementsScient'X2004—
−6K043479MC+ Partial VBRLdr Spine USA2005—
−5K080728LDR Spine Roi-C ImplantLdr Spine USA2008—
−4K083857LDR Spine Roi-C ImplantLdr Spine USA2009—
−3K091088LDR Spine Cervical Interbody Fusion SystemLdr Spine USA2009—
−2K111123Varilift Cervical Interbody Fusion SystemWenzel Spine2011—
−1K122801Providence Cervical CageProvidence Medical Technology, Inc.2013—
0 (this device)K161642CAVUX™ Cervical CageProvidence Medical Technology, Inc.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
199910
200010
200180
200250
200310
200440
200510
200610
200730
200840
200970
201210
FIG. 1 — Lineage of K161642, 1984–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ODP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODP device

  1. #1 K222276 CONDUIT Cages; FIBERGRAFT BG Puttyscore 53.4 · 25 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K122801Providence Cervical Cage
Summary page 4
…cal 5HJXODWLRQ1XPEHU 21 CFR 888.3080 3URGXFW&RGH ODP &ODVV Class II 3UHGLFDWH'HYLFHV 3ULPDU\3UHGLFDWHPMT Cervical Cage (K122801, Cleared 5/24/13) (This device has not been subject to recall.) 5HIHUHQFH'HYLFHTitan Spine…
Providence Medical Technology, Inc.2013—
†K100889Endoskeleton TCTitan Spine, LLC2010—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 32 years and passes through 8 companies; a new generation was cleared every 1.7 years on median.
  • 5 of the 51 ancestors have a recall of any class.

How does its category compare?

All ODP devices

ODP Intervertebral Fusion Device With Bone Graft, Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · ODP

11in 2025

2008: 82009: 122010: 92011: 252012: 172013: 182014: 262015: 242016: 172017: 332018: 252019: 222020: 142021: 182022: 122023: 342024: 102025: 112026 (partial year): 19
2007high 34 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODP

87in 2025

2008: 89 days median2009: 127 days median2010: 151 days median2011: 113 days median2012: 93 days median2013: 187 days median2014: 118 days median2015: 180 days median2016: 112 days median2017: 104 days median2018: 133 days median2019: 92 days median2020: 89 days median2021: 121 days median2022: 92 days median2023: 165 days median2024: 76 days median2025: 87 days median2026 (partial year): 117 days median
2007high 187 (2013) · low 76 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ODP

2in 2025

2009: 12011: 12013: 12020: 12025: 2
2007high 2 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ODP

57in 2025

2008: 22009: 212010: 542011: 382012: 922013: 782014: 432015: 512016: 372017: 392018: 512019: 1412020: 862021: 1612022: 502023: 362024: 552025: 57
2007high 161 (2021) · low 0 (2007)2025

MAUDE reports naming product code ODP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
200888902
200912127121
20109151054
201125113138
20121793092
201318187178
201426118043
201524180051
201617112037
201733104039
201825133051
201922920141
20201489186
2021181210161
20221292050
202334165036
20241076055
20251187257
2026191170—

What is it indicated for?

CAVUX™ Cervical Cage is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C3-C7) with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Patients should have received at least six weeks of non-operative treatment prior to treatment with the device. Devices are intended to be used with autogenous bone graft and supplemental fixation, such as an anterior plating system.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K161642: CAVUX™ Cervical Cage.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K161642

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026