InstruSafe (R) Sterilization Container

K180528510(k) TraditionalCleared Nov 16, 2018261-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Summit Medical, Inc. · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories

Cleared on Nov 16, 2018 as substantially equivalent to K123234 (Ermis Medizintechnik, 2013) after a 261-day review. Its family tree reaches back 6 generations to 2000.

Decided
Nov 16, 2018
Review
261 days
Class
Class II
Product code
KCT
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K991023 (2000). No later device cites it as a predicate yet.

  1. Root · 6 generations backK991023 Steritite Perforated Bottom Rigid Reusable Sterilization Container…Case Medical, Inc. · 2000
  2. 5 generations backK012931 Genesis Sterrad Compatible Reusable Sterilization Container SystemAllegiance Healthcare Corp. · 2002
  3. 4 generations backK023614 Steritite Rigid Reusable Sterilization Container SystemCase Medical, Inc. · 2003 · Recalled
  4. 3 generations backK050570 Miltex Rigid Sterilization Container SystemMiltex, Inc. · 2005
  5. 2 generations backK091720 Sklarlite Rigid Sterilization Container SystemSklar Corp. · 2010
  6. 1 generation backK123234 Ermis Sterilization Container SystemErmis Medizintechnik · 2013
  7. This deviceK180528 InstruSafe (R) Sterilization ContainerSummit Medical, Inc. · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K991023Steritite Perforated Bottom Rigid Reusable Sterilization Container System with…Case Medical, Inc.2000—
−5K012931Genesis Sterrad Compatible Reusable Sterilization Container SystemAllegiance Healthcare Corp.2002—
−4K023614Steritite Rigid Reusable Sterilization Container SystemCase Medical, Inc.20031
−3K050570Miltex Rigid Sterilization Container SystemMiltex, Inc.2005—
−2K091720Sklarlite Rigid Sterilization Container SystemSklar Corp.2010—
−1K123234Ermis Sterilization Container SystemErmis Medizintechnik2013—
0 (this device)K180528InstruSafe (R) Sterilization ContainerSummit Medical, Inc.2018—
FIG. 1 — Lineage of K180528, 2000–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KCT device

  1. #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K123234Ermis Sterilization Container System
Summary page 6
…on Container Summit Medical, Inc. Page 2 of 7 Predicate Device Trade/Device Name/510(k) Ermis Medizintechnik Sterilization Container System - K123234 Reference Device Trade/Device Name/510(k) Aesculap SterilContainer System – K112671 (reference) Comparison of Subject…
Ermis Medizintechnik2013—
†K112671Sterilcontainer SystemAesculap, Ltd.2012—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 6 companies; a new generation was cleared every 3.2 years on median.
  • 1 of the 6 ancestors has a recall of any class.

How does its category compare?

All KCT devices

KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · KCT

11in 2025

2007: 32008: 62009: 62010: 122011: 62012: 102013: 82014: 112015: 152016: 122017: 102018: 152019: 182020: 142021: 182022: 112023: 102024: 82025: 112026 (partial year): 9
2007high 18 (2019) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KCT

205in 2025

2007: 199 days median2008: 182 days median2009: 89 days median2010: 202 days median2011: 117 days median2012: 236 days median2013: 131 days median2014: 169 days median2015: 151 days median2016: 182 days median2017: 211 days median2018: 192 days median2019: 187 days median2020: 134 days median2021: 185 days median2022: 137 days median2023: 94 days median2024: 106 days median2025: 205 days median2026 (partial year): 122 days median
2007high 236 (2012) · low 89 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KCT

17in 2022

2010: 12011: 22013: 12014: 12016: 32017: 12021: 12022: 17
2007high 17 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KCT

50in 2025

2007: 22008: 82009: 52010: 32011: 32012: 22013: 62014: 52015: 62016: 162017: 32018: 222019: 152020: 662021: 262022: 82023: 302024: 182025: 50
2007high 66 (2020) · low 2 (2007)2025

MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007319902
2008618208
200968905
20101220213
2011611723
20121023602
2013813116
20141116915
20151515106
201612182316
20171021113
201815192022
201918187015
202014134066
202118185126
202211137178
20231094030
20248106018
202511205050
202691220—

What is it indicated for?

The InstruSafe® Sterilization Container is a reusable sterilization container system intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility for 180 days. The InstruSafe® Sterilization Container includes accessories such as trays, baskets, filters, data cards and tamper proof locks. The InstruSafe® Sterilization…

Read the full statement (220 words)

The InstruSafe® Sterilization Container is a reusable sterilization container system intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility for 180 days. The InstruSafe® Sterilization Container includes accessories such as trays, baskets, filters, data cards and tamper proof locks.

The InstruSafe® Sterilization Container consists of various models within the validated product line. All models are available with perforated lids and either perforated or non-perforated bottoms. All models are intended to be used with single use paper filters.

The container is a reusable device designed to be used with the following sterilization cycle parameters:

Pre-Vacuum Steam Sterilization Cycle:

4 minutes

1320C (270 oF)

Drying Time Minimum: 30 minutes

Model Number | Description Total Container Loaded | Load Description

Maximum Weight (Ibs)

CS-3XXX Full 1/1 Perforated Container Lid Not applicable Metal (Stainless Steel)

CS-3XXX Full 1/1 Container Bottom 25 Ibs surgical instruments

CS-2XXX Three quarter % Perforated Container Lid | Not applicable like forceps, scissors,

CS-2XXX Three quarter % Container Bottom 25 Ibs clamps, etc. including

CS-1XXX One half % Perforated Container Lid Not applicable lumened /cannulated

CS-1XXX One half ¥ Container Bottom 18 Ibs Instruments.

CS-5XXX XL Perforated Container Lid Not applicable

CS-5XXX XL Container Bottom 25 lbs

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K180528: InstruSafe (R) Sterilization Container.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K180528

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026