510(k) Report

510(k) · Cleared

Cleared

SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6800, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900

K192929510(k) SpecialCleared Dec 10, 201954-day reviewClass II21 CFR 880.6885

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

STERIS Corporation · MED Sterilant, Medical Devices

Cleared on Dec 10, 2019 as substantially equivalent to K190104 (Steris Corporations, 2019) and 2 other predicates after a 54-day review. Its family tree reaches back 5 generations to 2016. 8 later devices descend from it.

Decided
Dec 10, 2019
Review
54 days
Class
Class II
Product code
MED
Recalls
None
Predicates
3

Its longest line of descent runs back 5 generations to K161683 (2016). 7 ancestors in all. 8 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2019: 1 other ancestor2018: 1 other ancestor2021: 2 descendants cleared2023: 3 descendants cleared2022: 1 descendant cleared2024: 1 descendant cleared2026: 1 descendant clearedK161683 · SYSTEM 1E Liquid Chemical Sterilant Processing System · STERIS Corporation · 2016K170956 · SYSTEM 1E Liquid Chemical Sterilant Processing System · STERIS Corporation · 2017K173256 · System 1 endo Liquid Chemical Sterilant Processing System · STERIS Corporation · 2018K182827 · SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model 6900 · STERIS Corporation · 2019K191343 · SYSTEM 1 endo Liquid Chemical Sterilant Processing System,Model P6900 · STERIS Corporation · 2019201620182020202220242026
  1. Root · 5 generations backK161683 SYSTEM 1E Liquid Chemical Sterilant Processing SystemSTERIS Corporation · 2016
  2. 4 generations backK170956 SYSTEM 1E Liquid Chemical Sterilant Processing SystemSTERIS Corporation · 2017
  3. 3 generations backK173256 System 1 endo Liquid Chemical Sterilant Processing SystemSTERIS Corporation · 2018
  4. 2 generations backK182827 SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model 6900STERIS Corporation · 2019
  5. 1 generation backK191343 SYSTEM 1 endo Liquid Chemical Sterilant Processing System,Model P6900STERIS Corporation · 2019
  6. This deviceK192929 SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo…STERIS Corporation · 2019
  7. Descendant · cites it directly · 7 of its ownK210737 SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo…STERIS Corporation · 2021
  8. Descendant · 2 generations on · 6 of its ownK211607 SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo…STERIS Corporation · 2021
  9. Descendant · 3 generations on · 3 of its ownK222615 SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo…STERIS Corporation · 2022
  10. Descendant · 3 generations on · 1 of its ownK232914 SYSTEM 1E Liquid Chemical Sterilant Processing System (P6500)…STERIS Corporation · 2023
  11. Descendant · 3 generations on · 1 of its ownK230930 enspire 3000 Cleaning and Liquid Chemical Sterile Processing SystemSTERIS Corporation · 2023

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2021: 22022: 12023: 32024: 12026: 1
2021high 3 (2023) · low 0 (2025)2026

Most influential descendants

Showing 5 of 8 · See all
  • K210737SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical…STERIS Corporation · 2021 · cites it directly7descendants
  • K211607SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical…STERIS Corporation · 2021 · 2 generations on6descendants
  • K222615SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical…STERIS Corporation · 2022 · 3 generations on3descendants
  • K232914SYSTEM 1E Liquid Chemical Sterilant Processing System (P6500); SYSTEM 1 endo Liquid…STERIS Corporation · 2023 · 3 generations on1descendant
  • K230930enspire 3000 Cleaning and Liquid Chemical Sterile Processing SystemSTERIS Corporation · 2023 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K161683SYSTEM 1E Liquid Chemical Sterilant Processing SystemSTERIS Corporation2016—
−4K170956SYSTEM 1E Liquid Chemical Sterilant Processing SystemSTERIS Corporation2017—
−3K173256System 1 endo Liquid Chemical Sterilant Processing SystemSTERIS Corporation2018—
−2K182827SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model 6900STERIS Corporation2019—
−1K191343SYSTEM 1 endo Liquid Chemical Sterilant Processing System,Model P6900STERIS Corporation2019—
0 (this device)K192929SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid…STERIS Corporation2019—
+1K210737SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid…STERIS Corporation2021—
+2K211607SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid…STERIS Corporation2021—
+3K222615SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid…STERIS Corporation2022—
+3K232914SYSTEM 1E Liquid Chemical Sterilant Processing System (P6500); SYSTEM 1 endo…STERIS Corporation2023—
+3K230930enspire 3000 Cleaning and Liquid Chemical Sterile Processing SystemSTERIS Corporation2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201810
201910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202120
202210
202330
202410
202610
FIG. 1 — Lineage of K192929, 2016–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MED? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MED device

  1. #1 K251666 SYSTEM 1E Liquid Chemical Sterilant Processing…score 13.8 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K190104SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 Endo Liquid Chemical…
Summary page 7
…ssification Number: 21 CFR 880.6885 Product Code: MED 2. Predicate Device SYSTEM 1E Liquid Chemical Sterilant Processing System, K190104 3. Description of Device The SYSTEM 1E Liquid Chemical Sterilant Processing System is a liquid chemical sterilizati…
Steris Corporations2019—
*K173256System 1 endo Liquid Chemical Sterilant Processing System
Summary page 18
…cation Number: 21 CFR 880.6885 Product Code: MED 2. Predicate Device SYSTEM 1endo Liquid Chemical Sterilant Processing System: K173256 3. Description of Device The SYSTEM 1 endo Liquid Chemical Sterilant Processing System is a liquid chemical steriliz…
STERIS Corporation2018—
*K191343SYSTEM 1 endo Liquid Chemical Sterilant Processing System,Model P6900
Summary page 28
…21 CFR 880.6885 Product Code: MED 2. Predicate Device SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900, K191343. 3. Description of Device The SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900 is a liquid che…
STERIS Corporation2019—

What descends from it? (8)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K210737SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical…STERIS Corporation20217

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 1 company; a new generation was cleared every 7 months on median.
  • None of the 7 ancestors has a recall.
  • Of its descendants, K210737 (STERIS Corporation, 2021) has gone furthest, with 7 descendants of its own.

How does its category compare?

All MED devices

MED Sterilant, Medical Devices: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · MED

2in 2023

2007: 22008: 12010: 62012: 32013: 12014: 12016: 12017: 12018: 22019: 42021: 22022: 12023: 22026 (partial year): 2
2007high 6 (2010) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MED

84in 2019

2010: 281 days median2012: 111 days median2019: 84 days median
2007high 281 (2010) · low 84 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MED

2in 2011

2007: 32008: 22011: 2
2007high 3 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MED

9in 2025

2007: 342008: 792009: 1582010: 892011: 1062012: 3372013: 1402014: 1052015: 1102016: 1352017: 742018: 422019: 352020: 322021: 312022: 162023: 92024: 82025: 9
2007high 337 (2012) · low 8 (2024)2025

MAUDE reports naming product code MED, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—334
20081—279
20090—0158
20106281089
20110—2106
201231110337
20131—0140
20141—0105
20150—0110
20161—0135
20171—074
20182—042
2019484035
20200—032
20212—031
20221—016
20232—09
20240—08
20250—09
20262—0—

What is it indicated for?

The SYSTEM 1E Liquid Chemical Sterilant Processing System is intended for liquid chemical sterilization of cleaned, immersible, and reusable critical and semi-critical heat-sensitive medical devices in healthcare facilities. The SYSTEM 1E Processor dilutes the S40 Sterilant Concentrate to its use dilution (>1820 mg/L peracetic acid), liquid chemically sterilizes the load during a controlled 6-minute exposure at 45.5 to 60°C, and rinses the load with…

Read the full statement (409 words)

The SYSTEM 1E Liquid Chemical Sterilant Processing System is intended for liquid chemical sterilization of cleaned, immersible, and reusable critical and semi-critical heat-sensitive medical devices in healthcare facilities.

The SYSTEM 1E Processor dilutes the S40 Sterilant Concentrate to its use dilution (>1820 mg/L peracetic acid), liquid chemically sterilizes the load during a controlled 6-minute exposure at 45.5 to 60°C, and rinses the load with extensively treated* potable water. After completion of a cycle, critical devices should be used immediately; semi-critical devices should be used immediately or may be handled and stored in a manner similar to that of high level disinfected endoscopes. Critical devices not used immediately should be processed again before use.

The SYSTEM 1E Processor uses only S40 Sterilant Concentrate to liquid chemically sterilize medical devices.

* The extensive treatment of EPA potable water consists of:

1. Pre-filtration through two pre-filters:

• Pre-filter A is a gross depth filter that removes approximately 2.5 micron or larger particles/contaminants.

• Pre-filter B is a surface filter that removes particles/contaminants > 0.1 micron.

2. UV Irradiation:

• During transit through the UV water treatment chamber, a UV dose sufficient to achieve a > 6-log reduction of MS2 virus is delivered to the water.

3. 0.1 micron filtration:

• The water prepared by pre-filtration and UV irradiation is filtered through redundant, 0.1-micron (absolute rated) membranes to remove bacteria, fungi and protozoa > 0.1 micron.

The SYSTEM 1 endo Liquid Chemical Sterilant Processing System is intended for liquid chemical sterilization of cleaned, immersible, and reusable semi-critical medical devices and their accessories in healthcare facilities.

The SYSTEM 1 endo Processor automatically dilutes the S40 Sterilant Concentrate to its use dilution(> 1820 mg/L peracetic acid), liquid chemically sterilizes the load during a controlled 6-minute exposure at 45.5 to 60° C and rinses the load with 0.2 micron filtered water.

The SYSTEM 1 endo Processor uses only S40 Sterilant Concentrate to liquid chemically sterilize medical devices.

The SYSTEM 1 endo Liquid Chemical Sterilant Processing System is intended for liquid chemical sterilization of cleaned, immersible, and reusable semi-critical heat-sensitive medical devices and their accessories in healthcare facilities.

The SYSTEM 1 endo Processor automatically dilutes the S40 Sterilant Concentrate to its use dilution (> 1820 mg/L peracetic acid), liquid chemically sterilizes the load during a controlled 6-minute exposure at 45.5 to 60°C and rinses the load with 0.2 micron filtered water.

The SYSTEM 1 endo Processor uses only S40 Sterilant Concentrate to liquid chemically sterilize medical devices.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K192929: SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6800, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K192929

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026