510(k) Report

510(k) · Cleared

Cleared

Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7 Pulse CO-Oximeter and Accessories, Masimo Radius-7 Pulse CO-Oximeter and Accessories

K193242510(k) TraditionalCleared Feb 27, 202094-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Masimo Corporation · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Cleared on Feb 27, 2020 as substantially equivalent to K183697 (Masimo Corporation, 2019) and 1 other predicate after a 94-day review. Its family tree reaches back 22 generations to 1997. 2 of the 102 devices in its family, counting itself, have a Class I recall. 7 later devices descend from it.

Decided
Feb 27, 2020
Review
94 days
Class
Class II
Product code
MWI
Recalls
None
Predicates
2

Its longest line of descent runs back 22 generations to K962603 (1997). 94 ancestors in all, the oldest K853990 (1985). 7 later devices descend from it, 5 citing it directly. 2 of the 102 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2017: 1 other ancestor2010: 4 other ancestors2009: 1 other ancestor2005: 5 other ancestors2004: 7 other ancestors2011: 2 other ancestors2003: 6 other ancestors2000: 7 other ancestors1999: 6 other ancestors2002: 6 other ancestors, 1 with a Class I recall12001: 2 other ancestors1996: 3 other ancestors2008: 1 other ancestor1995: 5 other ancestors2006: 3 other ancestors1985: 1 other ancestor1990: 2 other ancestors1998: 4 other ancestors1997: 2 other ancestors, 1 with a Class I recall11991: 2 other ancestors1993: 1 other ancestor1992: 1 other ancestor2024: 1 descendant cleared2023: 3 descendants cleared2020: 1 descendant cleared2026: 1 descendant cleared2025: 1 descendant clearedReference device: K181956 · Masimo MightySat Rx Fingertip Pulse Oximeter · Masimo Corporation · 2019Reference device: K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999×2: 2 generations cleared close together, K012891 (2002), K021090 (2002) K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 2007K082268 · CAPNOSTREAM20 with Integrated Pulmonary Index · Oridion Capnography, Inc. · 2009 · recalledK091241 · Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse CO-Oximeter · Masimo Corporation · 2009K100428 · Masimo Rainbow Set Radical 7R Pulse CO-Oximeter · Masimo Corporation · 2010K110516 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K112687 · Connex (R) Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K121013 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2012×2: 2 generations cleared close together, K140188 (2014), K142394 (2014) K151644 · Masimo Root Vital Signs Monitoring System and Accessories · Masimo Corporation · 2016K170168 · Masimo Rad-97 and Accessories · Masimo Corporation · 2017K180046 · Masimo Rad-97 and Accessories · Masimo Corporation · 2018 · recalledK183697 · Masimo Rad-97 and Accessories · Masimo Corporation · 20191990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor3 generations back: 2 other ancestors4 generations back: 2 other ancestors5 generations back: 11 other ancestors6 generations back: 8 other ancestors, 1 with a Class I recall17 generations back: 10 other ancestors8 generations back: 8 other ancestors9 generations back: 6 other ancestors10 generations back: 5 other ancestors11 generations back: 7 other ancestors12 generations back: 5 other ancestors, 1 with a Class I recall113 generations back: 5 other ancestors14 generations back: 2 other ancestors 1 generation forward: 5 descendants2 generations forward: 2 descendants K183697 · Masimo Rad-97 and Accessories · Masimo Corporation · 2019K180046 · Masimo Rad-97 and Accessories · Masimo Corporation · 2018 · recalledK170168 · Masimo Rad-97 and Accessories · Masimo Corporation · 2017K151644 · Masimo Root Vital Signs Monitoring System and Accessories · Masimo Corporation · 2016K142394 · Masimo Root Monitoring System and Accesories · Masimo Corporation · 2014K140188 · Masimo Root Monitoring System · Masimo Corporation · 2014K121013 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2012K112687 · Connex (R) Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K110516 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K100428 · Masimo Rainbow Set Radical 7R Pulse CO-Oximeter · Masimo Corporation · 2010K091241 · Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse CO-Oximeter · Masimo Corporation · 2009K082268 · CAPNOSTREAM20 with Integrated Pulmonary Index · Oridion Capnography, Inc. · 2009 · recalledK072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 2007K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK021090 · Oximax N-550 Pulse Oximeter,Model N-550 Pulse Oximeter · Nellcor Puritan Bennett, Inc. · 2002K012891 · Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and Cables (Aka Accessories) · Nellcor Puritan Bennett, Inc. · 2002 · recalledK991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997−20−15−10−50
  1. Root · 22 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 18 generations between
  3. 3 generations backK170168 Masimo Rad-97 and AccessoriesMasimo Corporation · 2017
  4. 2 generations backK180046 Masimo Rad-97 and AccessoriesMasimo Corporation · 2018 · Recalled
  5. 1 generation backK183697 Masimo Rad-97 and AccessoriesMasimo Corporation · 2019
  6. This deviceK193242 Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7…Masimo Corporation · 2020
  7. Descendant · cites it directly · 1 of its ownK223498 Radius VSM and AccessoriesMasimo Corporation · 2023 · Recalled
  8. Descendant · cites it directly · 1 of its ownK201770 Masimo Rad-G Pulse Oximeter, Masimo Rad-G YI sensor, Masimo Rad-G…Masimo Corporation · 2020 · Recalled
  9. Descendant · cites it directly · 0 of its ownK253196 Midmark 800 Digital Vital Signs Device (1-300-0100, 1-300-0200…Midmark Corporation · 2026
  10. Descendant · 2 generations on · 0 of its ownK250757 Radius VSM and AccessoriesMasimo Corporation · 2025
  11. Descendant · cites it directly · 0 of its ownK241411 Welch Allyn Connex® Spot Monitor; 901058 Vital Signs Monitor Core…Welch Allyn, Inc. · 2024 · Recalled
Show all 22 generations
  1. Root · 22 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 21 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 20 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 19 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. 18 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
  6. 17 generations backK021090 Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc. · 2002
  7. 16 generations backK033048 Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS…Cas Medical Systems, Inc. · 2004 · Recalled
  8. 15 generations backK050844 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL…Cas Medical Systems, Inc. · 2005
  9. 14 generations backK060065 CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One…Oridion Capnography, Inc. · 2006 · Recalled
  10. 13 generations backK072295 Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc. · 2007
  11. 12 generations backK082268 CAPNOSTREAM20 with Integrated Pulmonary IndexOridion Capnography, Inc. · 2009 · Recalled
  12. 11 generations backK091241 Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse…Masimo Corporation · 2009
  13. 10 generations backK100428 Masimo Rainbow Set Radical 7R Pulse CO-OximeterMasimo Corporation · 2010
  14. 9 generations backK110516 Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2011
  15. 8 generations backK112687 Connex (R) Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2011
  16. 7 generations backK121013 Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2012
  17. 6 generations backK140188 Masimo Root Monitoring SystemMasimo Corporation · 2014
  18. 5 generations backK142394 Masimo Root Monitoring System and AccesoriesMasimo Corporation · 2014
  19. 4 generations backK151644 Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation · 2016
  20. 3 generations backK170168 Masimo Rad-97 and AccessoriesMasimo Corporation · 2017
  21. 2 generations backK180046 Masimo Rad-97 and AccessoriesMasimo Corporation · 2018 · Recalled
  22. 1 generation backK183697 Masimo Rad-97 and AccessoriesMasimo Corporation · 2019
  23. This deviceK193242 Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7…Masimo Corporation · 2020

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2020: 12023: 32024: 12025: 12026: 1
2020high 3 (2023) · low 0 (2021)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 7 · See all
  • K223498Radius VSM and AccessoriesMasimo Corporation · 2023 · cites it directly1descendant
  • K201770Masimo Rad-G Pulse Oximeter, Masimo Rad-G YI sensor, Masimo Rad-G Reusable sensorMasimo Corporation · 2020 · cites it directly1descendant
  • K253196Midmark 800 Digital Vital Signs Device (1-300-0100, 1-300-0200, 1-300-0300, 1-300-0400)Midmark Corporation · 2026 · cites it directly0descendants
  • K250757Radius VSM and AccessoriesMasimo Corporation · 2025 · 2 generations on0descendants
  • K241411Welch Allyn Connex® Spot Monitor; 901058 Vital Signs Monitor Core (CSM)Welch Allyn, Inc. · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−22K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−21K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−20K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−19K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
−18K012891Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and…Nellcor Puritan Bennett, Inc.20021
−17K021090Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc.2002—
−16K033048Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL…Cas Medical Systems, Inc.20041
−15K050844750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL…Cas Medical Systems, Inc.2005—
−14K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter…Oridion Capnography, Inc.20063
−13K072295Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc.2007—
−12K082268CAPNOSTREAM20 with Integrated Pulmonary IndexOridion Capnography, Inc.20099
−11K091241Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse CO-OximeterMasimo Corporation2009—
−10K100428Masimo Rainbow Set Radical 7R Pulse CO-OximeterMasimo Corporation2010—
−9K110516Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.2011—
−8K112687Connex (R) Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.2011—
−7K121013Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.2012—
−6K140188Masimo Root Monitoring SystemMasimo Corporation2014—
−5K142394Masimo Root Monitoring System and AccesoriesMasimo Corporation2014—
−4K151644Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation2016—
−3K170168Masimo Rad-97 and AccessoriesMasimo Corporation2017—
−2K180046Masimo Rad-97 and AccessoriesMasimo Corporation20181
−1K183697Masimo Rad-97 and AccessoriesMasimo Corporation2019—
0 (this device)K193242Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7 Pulse…Masimo Corporation2020—
+1K223498Radius VSM and AccessoriesMasimo Corporation20232
+1K201770Masimo Rad-G Pulse Oximeter, Masimo Rad-G YI sensor, Masimo Rad-G Reusable…Masimo Corporation20202
+1K253196Midmark 800 Digital Vital Signs Device (1-300-0100, 1-300-0200, 1-300-0300…Midmark Corporation2026—
+2K250757Radius VSM and AccessoriesMasimo Corporation2025—
+1K241411Welch Allyn Connex® Spot Monitor; 901058 Vital Signs Monitor Core (CSM)Welch Allyn, Inc.20241

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
199020
199120
199210
199310
199550
199630
199721
199840
199960
200070
200120
200261
200360
200470
200550
200630
200810
200910
201040
201120
201710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
202330
202410
202510
202610
FIG. 1 — Lineage of K193242, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWI device

  1. #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K183697Masimo Rad-97 and Accessories
Summary page 9
…880.2910, Class II/FLL Establishment Registration 2031172 Number: Reason for Premarket Addition of RRp Feature Notification: Predicate Device: K183697 – Masimo Rad-97 and Accessories Reference predicate: K181956 – Masimo MightySat Rx Fingertip Pulse Oximeter Performance…
Masimo Corporation2019—
*K171121Masimo Root Monitoring System and Accessories
Summary page 10
…870.2710, Class II/DPZ Establishment Registration 2031172 Number: Reason for Premarket Addition of RRp Feature Notification: Predicate Device: K171121 – Masimo Radical-7 Pulse CO-Oximeter and Accessories Reference predicate: K181956 – Masimo…
Masimo Corporation2017—
†K181956Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation2019—
†K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside MonitorOridion Capnography, Inc.20063

Also cleared against K183697: 1 other device →

What descends from it? (7)

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K223498Radius VSM and AccessoriesMasimo Corporation20231
K201770Masimo Rad-G Pulse Oximeter, Masimo Rad-G YI sensor, Masimo Rad-G Reusable sensorMasimo Corporation20201
K253196Midmark 800 Digital Vital Signs Device (1-300-0100, 1-300-0200, 1-300-0300, 1-300-0400)Midmark Corporation20260
K241411Welch Allyn Connex® Spot Monitor; 901058 Vital Signs Monitor Core (CSM)Welch Allyn, Inc.20240
K212161Radical-7 Pulse CO-Oximeter and Accessories, Rad-97 and AccessoriesMasimo Corporation20230

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K022732Infant/Child Reduced Energy ElectrodesMedtronic Physio-Control Corp. · 2002 · 6 generations back · ◆ in the 2002 ancestors bar of FIG. 12 Class I recalls
  • K970209Capnocheck PlusBci Intl., Inc. · 1997 · 12 generations back · ◆ in the 1997 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 23 years and passes through 7 companies; a new generation was cleared every 11 months on median.
  • 21 of the 94 ancestors have a recall of any class; 2 have a Class I recall.
  • Of its descendants, K223498 (Masimo Corporation, 2023) has gone furthest, with 1 descendant of its own.
  • 1 other device also cites its predicate K183697.

How does its category compare?

All MWI devices

MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · MWI

4in 2025

2007: 92008: 92009: 62010: 172011: 112012: 132013: 202014: 162015: 192016: 122017: 132018: 112019: 142020: 82021: 92022: 52023: 82024: 102025: 42026 (partial year): 6
2007high 20 (2013) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWI

247in 2025

2007: 42 days median2008: 49 days median2009: 112 days median2010: 58 days median2011: 78 days median2012: 104 days median2013: 85 days median2014: 148 days median2015: 127 days median2016: 165 days median2017: 205 days median2018: 217 days median2019: 255 days median2020: 138 days median2021: 161 days median2022: 231 days median2023: 250 days median2024: 202 days median2025: 247 days median2026 (partial year): 239 days median
2007high 255 (2019) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWI

9so far in 2026, the most since 2007

2007: 12008: 12009: 22010: 22011: 32012: 52013: 32014: 62015: 12017: 22019: 42022: 22024: 52026 (partial year): 9
2007high 9 (2026) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWI

182in 2025

2007: 32008: 32009: 202010: 172011: 162012: 312013: 422014: 302015: 312016: 512017: 852018: 1582019: 1692020: 1102021: 1882022: 1682023: 1792024: 1202025: 182
2007high 188 (2021) · low 3 (2007)2025

MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200794213
200894913
20096112220
20101758217
20111178316
201213104531
20132085342
201416148630
201519127131
201612165051
201713205285
2018112170158
2019142554169
202081380110
202191610188
202252312168
202382500179
2024102025120
202542470182
202662399—

What is it indicated for?

Masimo Rad-97 Pulse CO-Oximeter and Accessories: The Masimo Rad-97 and Accessories can communicate with network systems for supplemental remote viewing and alarming (e.g., at a central station). In addition, the Masimo Rad-97 and Accessories are indicated to provide the continuous non-invasive monitoring data obtained from the Masimo Rad-97 and Accessories for functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) to…

Read the full statement (1,027 words)

Masimo Rad-97 Pulse CO-Oximeter and Accessories:

The Masimo Rad-97 and Accessories can communicate with network systems for supplemental remote viewing and alarming (e.g., at a central station). In addition, the Masimo Rad-97 and Accessories are indicated to provide the continuous non-invasive monitoring data obtained from the Masimo Rad-97 and Accessories for functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) to multi-parameter devices for the display on those devices.

The Masimo Rad-97 and Accessories are indicated for the continuous non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) of adult, pediatric, and neonatal patients during both no motion and motion conditions, and for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and home environments.

The Masimo Rad-97 and Accessories are indicated for the continuous non-invasive monitoring of carboxyhemoglobin saturation (SpCO) of adult, pediatric, and infant patients during no motion conditions in hospitals and hospital-type facilities. The Masimo Rad-97 and Accessories are not intended to be used as the sole basis for making diagnosis or treatment decisions related to suspected carbon monoxide poisoning; it is intended to be used in conjunction with additional methods of assessing clinical signs and symptoms.

The Masimo Rad-97 and Accessories are indicated for the continuous non-invasive monitoring of methemoglobin saturation (SpMet) of adult, pediatric, and neonatal patients during no motion conditions in hospitals and hospital-type facilities.

The Masimo Rad-97 and Accessories are indicated for the continuous non-invasive monitoring of total hemoglobin concentration (SpHb) of adult and pediatric patients during no motion conditions in hospitals and hospital-type facilities.

The Masimo Rad-97 and Accessories are indicated for the continuous non-invasive monitoring of respiratory rate (RRa) for adult, pediatric, and neonatal patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities.

The optional Nomoline Capnography product family is intended to be connected to other medical backboard devices for monitoring of breath rate and CO2. The Nomoline Capnography product family is intended to be connected to a patient breathing circuit for monitoring of inspired/expired gases during anesthesia, recovery and respiratory care. The environment is the operating suite, intensive care unit and patient room. The intended patient population is adult, pediatric and infant patients.

The optional non-invasive blood pressure (NiBP) module is indicated for the noninvasive measurement of arterial blood pressure. The NiBP module is designed to measure blood pressure for patient population described in the following Table:

Patient Population Approximate Age Range

Newborn (neonate) Birth to 1 month of age

Infant 1 month to 2 years of age

Child 2 to 12 years of age

Adolescent 12-21 years of age

Adult 21 years of age and older

Devices with Masimo technology are only to be used with Masimo sensors and cables.

The Masimo Rad-97 and Accessories are indicated for the continuous non-invasive monitoring of Respiratory Rate from photoplethysmogram (RRp) for adult and pediatric patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities.

Masimo Radical-7 Pulse CO-Oximeter and Accessories

The Radical-7 and Accessories are indicated for the continuous non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) of adult, pediatric, and neonatal patients during both no motion and motion conditions, and for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and home environments.

The Radical-7 and Accessories are indicated for the continuous non-invasive monitoring of carboxyhemoglobin saturation (SpCO) of adult, pediatric, and infant patients during no motion conditions in hospitals and hospital-type facilities. The Masimo Radical-7 and Accessories are not intended to be used as the sole basis for making diagnosis or treatment decisions related to suspected carbon monoxide poisoning; it is intended to be used in conjunction with additional methods of assessing clinical signs and symptoms.

The Radical-7 and Accessories are indicated for the continuous non-invasive monitoring of methemoglobin saturation (SpMet) of adult, pediatric, and neonatal patients during no motion conditions in hospitals and hospital-type facilities.

The Radical-7 and Accessories are indicated for the continuous non-invasive monitoring of total hemoglobin concentration (SpHb) of adult and pediatric patients during no motion conditions in hospitals and hospital-type facilities.

The Radical-7 and Accessories are indicated for the continuous non-invasive monitoring of respiratory rate (RRa) for adult, pediatric, and neonatal patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities.

The Radical-7 and Accessories are indicated for the continuous non-invasive monitoring of Respiratory Rate from photoplethysmogram (RRp) for adult and pediatric patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities.

Masimo Radius-7 Pulse CO-Oximeter and Accessories:

The Radius-7 Accessories are indicated for the continuous non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) of adult, pediatric, and neonatal patients during both no motion and motion conditions, and for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and home environments.

The Radius-7 and Accessories are indicated for the continuous non-invasive monitoring of carboxyhemoglobin saturation (SpCO) of adult, pediatric, and infant patients during no motion conditions in hospitals and hospital-type facilities. The Masimo Radius and Accessories are not intended to be used as the sole basis for making diagnosis or treatment decisions related to suspected carbon monoxide poisoning; it is intended to be used in conjunction with additional methods of assessing clinical signs and symptoms.

The Radius-7 and Accessories are indicated for the continuous non-invasive monitoring of methemoglobin saturation (SpMet) of adult, pediatric, and neonatal patients during no motion conditions in hospitals and hospital-type facilities.

The Radius-7 and Accessories are indicated for the continuous non-invasive monitoring of total hemoglobin concentration (SpHb) of adult and pediatric patients during no motion conditions in hospitals and hospital-type facilities.

The Radius-7 and Accessories are indicated for the continuous non-invasive monitoring of respiratory rate (RRa) for adult, pediatric, and neonatal patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities.

The Radius-7 and Accessories are indicated for the continuous non-invasive monitoring of Respiratory Rate from Pleth (RRp) for adult and pediatric patients during no motion conditions in hospitals, hospital-type facilities, home environments, and transport within healthcare facilities.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K193242: Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7 Pulse CO-Oximeter and Accessories, Masimo Radius-7 Pulse CO-Oximeter and Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K193242

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026