510(k) · Cleared
ClearedApache Ultrasound System (Model C62)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Compal Electronics, Inc. · IYN System, Imaging, Pulsed Doppler, Ultrasonic
Cleared on Nov 12, 2020 as substantially equivalent to K192107 (Clarius Mobile Health Corp., 2019) after a 108-day review. Its family tree reaches back 26 generations to 1995. 6 of the 325 devices in its family, counting itself, have a Class I recall.
- Decided
- Nov 12, 2020
- Review
- 108 days
- Class
- Class II
- Product code
- IYN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 26 generations to K935595 (1995). 324 ancestors in all, the oldest K850478 (1985). No later device cites it as a predicate yet. 6 of the 325 devices in this family, counting this one, have a Class I recall.
- Root · 26 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
- 22 generations between
- 3 generations backK172162 ACUSON S3000 S2000 S1000 Diagnostic Ultrasound SystemsSiemens Healthcare · 2017
- 2 generations backK180799 Clarius Ultrasound ScannerClarius Mobile Health Corp. · 2018
- 1 generation backK192107 Clarius Ultrasound ScannerClarius Mobile Health Corp. · 2019
- This deviceK202074 Apache Ultrasound System (Model C62)Compal Electronics, Inc. · 2020
Show all 26 generations
- Root · 26 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
- 25 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
- 24 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
- 23 generations backK032114 Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2003
- 22 generations backK041319 Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
- 21 generations backK042770 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
- 20 generations backK050240 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
- 19 generations backK052894 Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
- 18 generations backK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
- 17 generations backK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
- 16 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
- 15 generations backK083095 Sonixtouch Ultrasound SystemUltrasonix Medical Corporation · 2008
- 14 generations backK092271 GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3…GE Healthcare · 2009 · Recalled
- 13 generations backK110943 Logiq E9GE Healthcare · 2011 · Recalled
- 12 generations backK113690 GE Logiq I, Logiq E and Vivid EGE Healthcare · 2011 · Recalled
- 11 generations backK121699 Acuson X300 Diagnostic Ultrasound System Sonovista X300 Diagnostic…Siemens Medical Solutions USA, Inc. · 2012
- 10 generations backK123001 Acuson X700 Diagnstic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2012 · Recalled
- 9 generations backK132804 Acuson S1000 / S2000 / S3000Siemens Medical Solutions USA, Inc. Ultrasound Gro · 2013 · Recalled
- 8 generations backK140959 Acuson S1000, S2000, S3000 Diagnostic Ultrasound SystemsSiemens Medical Solutions USA, Inc. · 2014
- 7 generations backK142876 ACUSON S1000/ S2000/ S3000 Diagnostic Ultrasound SystemsSiemens Medical Solutions USA, Inc. · 2014 · Recalled
- 6 generations backK152369 ACUSON S1000, S2000, S3000 Diagnostic Ultrasuond SystemSiemens Medical Solutions USA, Inc. Ultrasound Group · 2015
- 5 generations backK162243 ACUSON S1000 / S2000 / S3000 Diagnostic Ultrasound SystemSiemens Medi Cal Solutions, Inc. · 2016
- 4 generations backK163635 ACUSON S1000/S2000/S3000 Diagnostic Ultrasound SystemsSiemens Medical Solutions USA, Inc. Ultrasound Group · 2017 · Recalled
- 3 generations backK172162 ACUSON S3000 S2000 S1000 Diagnostic Ultrasound SystemsSiemens Healthcare · 2017
- 2 generations backK180799 Clarius Ultrasound ScannerClarius Mobile Health Corp. · 2018
- 1 generation backK192107 Clarius Ultrasound ScannerClarius Mobile Health Corp. · 2019
- This deviceK202074 Apache Ultrasound System (Model C62)Compal Electronics, Inc. · 2020
Class I recalls in this family
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −26 | K935595 | Acuson Model 3001 | Acuson Corp. | 1995 | — |
| −25 | K973767 | Harmonic Imaging with Contrast | Acuson Corp. | 1997 | — |
| −24 | K022567 | Sequoia Signature II Diagnostic Ultrasound System | Acuson Corp. | 2002 | — |
| −23 | K032114 | Sequoia 8.0 Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc. | 2003 | — |
| −22 | K041319 | Sequoia Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc. | 2004 | — |
| −21 | K042770 | Modification to Acuson CV70 Cardiovascular System | Siemens Medical Solutions USA, Inc. | 2004 | 1 |
| −20 | K050240 | Modification to Acuson CV70 Cardiovascular System | Siemens Medical Solutions USA, Inc. | 2005 | 1 |
| −19 | K052894 | Sonoline G60 S Ultrasound System | Siemens Medical Solutions USA, Inc. | 2005 | 1 |
| −18 | K063138 | Modification to Acuson Antares Ultrasound System | Siemens Medical Solutions USA, Inc. | 2006 | — |
| −17 | K063803 | Acuson Antares Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc., Ultrasound DI | 2007 | 9 |
| −16 | K072786 | Acuson S2000 Ultrasound System | Siemens Medical Solutions USA, Inc. | 2007 | — |
| −15 | K083095 | Sonixtouch Ultrasound System | Ultrasonix Medical Corporation | 2008 | — |
| −14 | K092271 | GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4 | GE Healthcare | 2009 | 1 |
| −13 | K110943 | Logiq E9 | GE Healthcare | 2011 | 2 |
| −12 | K113690 | GE Logiq I, Logiq E and Vivid E | GE Healthcare | 2011 | 1 |
| −11 | K121699 | Acuson X300 Diagnostic Ultrasound System Sonovista X300 Diagnostic Ultrasound… | Siemens Medical Solutions USA, Inc. | 2012 | — |
| −10 | K123001 | Acuson X700 Diagnstic Ultrasound System | Siemens Medical Solutions USA, Inc. | 2012 | 2 |
| −9 | K132804 | Acuson S1000 / S2000 / S3000 | Siemens Medical Solutions USA, Inc. Ultrasound Gro | 2013 | 3 |
| −8 | K140959 | Acuson S1000, S2000, S3000 Diagnostic Ultrasound Systems | Siemens Medical Solutions USA, Inc. | 2014 | — |
| −7 | K142876 | ACUSON S1000/ S2000/ S3000 Diagnostic Ultrasound Systems | Siemens Medical Solutions USA, Inc. | 2014 | 1 |
| −6 | K152369 | ACUSON S1000, S2000, S3000 Diagnostic Ultrasuond System | Siemens Medical Solutions USA, Inc. Ultrasound Group | 2015 | — |
| −5 | K162243 | ACUSON S1000 / S2000 / S3000 Diagnostic Ultrasound System | Siemens Medi Cal Solutions, Inc. | 2016 | — |
| −4 | K163635 | ACUSON S1000/S2000/S3000 Diagnostic Ultrasound Systems | Siemens Medical Solutions USA, Inc. Ultrasound Group | 2017 | 1 |
| −3 | K172162 | ACUSON S3000 S2000 S1000 Diagnostic Ultrasound Systems | Siemens Healthcare | 2017 | — |
| −2 | K180799 | Clarius Ultrasound Scanner | Clarius Mobile Health Corp. | 2018 | — |
| −1 | K192107 | Clarius Ultrasound Scanner | Clarius Mobile Health Corp. | 2019 | — |
| 0 (this device) | K202074 | Apache Ultrasound System (Model C62) | Compal Electronics, Inc. | 2020 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1985 | 1 | 0 |
| 1986 | 1 | 0 |
| 1987 | 1 | 0 |
| 1988 | 1 | 0 |
| 1989 | 5 | 0 |
| 1990 | 1 | 0 |
| 1991 | 5 | 0 |
| 1992 | 2 | 0 |
| 1993 | 6 | 0 |
| 1994 | 10 | 0 |
| 1995 | 9 | 0 |
| 1996 | 10 | 1 |
| 1997 | 12 | 0 |
| 1998 | 17 | 3 |
| 1999 | 17 | 0 |
| 2000 | 15 | 1 |
| 2001 | 18 | 0 |
| 2002 | 22 | 0 |
| 2003 | 20 | 0 |
| 2004 | 20 | 1 |
| 2005 | 17 | 0 |
| 2006 | 11 | 0 |
| 2007 | 14 | 0 |
| 2008 | 11 | 0 |
| 2009 | 11 | 0 |
| 2010 | 9 | 0 |
| 2011 | 5 | 0 |
| 2012 | 10 | 0 |
| 2013 | 9 | 0 |
| 2014 | 2 | 0 |
| 2015 | 3 | 0 |
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
6 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IYN device
- #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K192107 | Clarius Ultrasound ScannerSummary page 5…ices in alignment with the FDA’s standard terminology for comparable devices. The predicate device selected to demonstrate equivalence is the Clarius Ultrasound Scanner (K192107). 2 Determination of Substantial Equivalence The subject device “A… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (6 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K040050Instatrak System with Multiple Dataset Navigation, Model IT3500Ge Medical Systems Navigation and Visualization IN · 2004 · 10 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
- K994270Instatrak 3000 System with Fluorotrak Module, Model IT3000Visualization Technology, Inc. · 2000 · 10 generations back · ◆ in the 2000 ancestors bar of FIG. 12 Class I recalls
- K983529Instatrak 3000Visualization Technology, Inc. · 1998 · 10 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
- K982994Skull Base Instatrak SystemVisualization Technology, Inc. · 1998 · 10 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
- K981998Pediatric Instatrak SystemVisualization Technology, Inc. · 1998 · 10 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
- K960330InstatrakVisualization Technology, Inc. · 1996 · 10 generations back · ◆ in the 1996 ancestors bar of FIG. 11 Class I recall
Nearest 5 of 6; all are on the web page.
What does this lineage say?
- The line of descent spans 25 years and passes through 11 companies; a new generation was cleared every 11 months on median.
- 85 of the 324 ancestors have a recall of any class; 6 have a Class I recall.
- 6 other devices also cite its predicate K192107.
How does its category compare?
All IYN devicesIYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · IYN
57in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IYN
124in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IYN
10in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · IYN
610in 2025
MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 26 | 16 | 3 |
| 2008 | 25 | 18 | 12 | 2 |
| 2009 | 18 | 29 | 8 | 9 |
| 2010 | 29 | 67 | 10 | 17 |
| 2011 | 39 | 46 | 8 | 18 |
| 2012 | 43 | 37 | 3 | 20 |
| 2013 | 51 | 60 | 8 | 18 |
| 2014 | 56 | 39 | 2 | 48 |
| 2015 | 54 | 55 | 3 | 116 |
| 2016 | 60 | 56 | 2 | 145 |
| 2017 | 64 | 83 | 0 | 146 |
| 2018 | 59 | 85 | 7 | 85 |
| 2019 | 47 | 79 | 0 | 59 |
| 2020 | 57 | 72 | 4 | 67 |
| 2021 | 46 | 105 | 8 | 213 |
| 2022 | 53 | 105 | 10 | 186 |
| 2023 | 44 | 115 | 4 | 229 |
| 2024 | 50 | 119 | 1 | 266 |
| 2025 | 57 | 124 | 10 | 610 |
| 2026 | 44 | 107 | 2 (1) | — |
What is it indicated for?
The Apache Ultrasound System (Model: C62) is intended for diagnostic ultrasound imaging and fluid flow analysis in the following applications: Abdominal, Fetal/Obstetric, Gynecological, Fetal Echo, Musculo-skeletal (conventional), Urology, and Pediatric. The system provides diagnostic ultrasound imaging in B, Color Doppler, and M modes. The clinical environments where the system can be used include physician offices, clinics, hospitals, and clinical…
Read the full statement (95 words)
The Apache Ultrasound System (Model: C62) is intended for diagnostic ultrasound imaging and fluid flow analysis in the following applications: Abdominal, Fetal/Obstetric, Gynecological, Fetal Echo, Musculo-skeletal (conventional), Urology, and Pediatric. The system provides diagnostic ultrasound imaging in B, Color Doppler, and M modes. The clinical environments where the system can be used include physician offices, clinics, hospitals, and clinical point-of-care for diagnosis of patients except environments where intensity of electromagnetic disturbances is high.
The Apache Ultrasound System is a portable ultrasound system intended for use in environments where healthcare is provided by trained healthcare professionals.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K202074 · printed Nov 3, 2026
Cite this page
510(k) Report. “K202074: Apache Ultrasound System (Model C62).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K202074
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026