ControlRad Select Model Z, ControlRad Trace Model 8, ControlRad Trace Model 9

K211782510(k) SpecialCleared Jul 1, 202122-day reviewClass II21 CFR 892.1650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Controlrad, Inc. · OWB Interventional Fluoroscopic X-Ray System

Cleared on Jul 1, 2021 as substantially equivalent to K202431 (Controlrad, Inc., 2020) and 2 other predicates after a 22-day review. Its family tree reaches back 9 generations to 2002. 2 of the 11 devices in its family, counting itself, have a Class I recall.

Decided
Jul 1, 2021
Review
22 days
Class
Class II
Product code
OWB
Recalls
None
Predicates
3

Its longest line of descent runs back 9 generations to K021049 (2002). 10 ancestors in all. No later device cites it as a predicate yet. 2 of the 11 devices in this family, counting this one, have a Class I recall.

  1. Root · 9 generations backK021049 Oec 9800 Plus Digital Mobile Imaging SystemGe Oec Medical Systems · 2002 · Recalled (Class I)
  2. 5 generations between
  3. 3 generations backK183109 ControlRad Trace Model 8Controlrad, Inc. · 2019
  4. 2 generations backK200663 ControlRad Trace Model 9Controlrad, Inc. · 2020
  5. 1 generation backK202431 ControlRad Select Model ZControlrad, Inc. · 2020
  6. This deviceK211782 ControlRad Select Model Z, ControlRad Trace Model 8, ControlRad…Controlrad, Inc. · 2021
Show all 9 generations
  1. Root · 9 generations backK021049 Oec 9800 Plus Digital Mobile Imaging SystemGe Oec Medical Systems · 2002 · Recalled (Class I)
  2. 8 generations backK041932 Oec Olympus Fluoroscopic Imaging SystemGe Oec Medical Systems, Inc. · 2004 · Recalled
  3. 7 generations backK073543 Oec 9900 EliteGe Oec Medical Systems · 2008 · Recalled
  4. 6 generations backK082781 Oec 9900 EliteGe Healthcare Surgery · 2009 · Recalled
  5. 5 generations backK111551 Oec (R) 9800, Oec (R) 9800 PlusGe Oec Medical Systems, Inc. · 2011 · Recalled
  6. 4 generations backK132027 Oec 9800 PlusGe Oec Medical Systems, Inc. · 2014 · Recalled
  7. 3 generations backK183109 ControlRad Trace Model 8Controlrad, Inc. · 2019
  8. 2 generations backK200663 ControlRad Trace Model 9Controlrad, Inc. · 2020
  9. 1 generation backK202431 ControlRad Select Model ZControlrad, Inc. · 2020
  10. This deviceK211782 ControlRad Select Model Z, ControlRad Trace Model 8, ControlRad…Controlrad, Inc. · 2021

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K021049Oec 9800 Plus Digital Mobile Imaging SystemGe Oec Medical Systems2002Class I
−8K041932Oec Olympus Fluoroscopic Imaging SystemGe Oec Medical Systems, Inc.20047
−7K073543Oec 9900 EliteGe Oec Medical Systems20085
−6K082781Oec 9900 EliteGe Healthcare Surgery20094
−5K111551Oec (R) 9800, Oec (R) 9800 PlusGe Oec Medical Systems, Inc.20119
−4K132027Oec 9800 PlusGe Oec Medical Systems, Inc.20148
−3K183109ControlRad Trace Model 8Controlrad, Inc.2019—
−2K200663ControlRad Trace Model 9Controlrad, Inc.2020—
−1K202431ControlRad Select Model ZControlrad, Inc.2020—
0 (this device)K211782ControlRad Select Model Z, ControlRad Trace Model 8, ControlRad Trace Model 9Controlrad, Inc.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200311
FIG. 1 — Lineage of K211782, 2002–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.2 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K202431ControlRad Select Model Z
Summary page 7
…Primary Predicate Trade Name ControlRad® Select Model Z ControlRad® Trace Model 9 ControlRad® Trace Model 8 510(k) Clearance K202431 K200663 K183109 Clearance Date December 23, 2020 June…
Controlrad, Inc.2020—
*K200663ControlRad Trace Model 9
Summary page 7
…ame ControlRad® Select Model Z ControlRad® Trace Model 9 ControlRad® Trace Model 8 510(k) Clearance K202431 K200663 K183109 Clearance Date December 23, 2020 June 24, 2020 May…
Controlrad, Inc.2020—
*K183109ControlRad Trace Model 8
Summary page 7
…elect Model Z ControlRad® Trace Model 9 ControlRad® Trace Model 8 510(k) Clearance K202431 K200663 K183109 Clearance Date December 23, 2020 June 24, 2020 May 13, 2019 Classification Na…
Controlrad, Inc.2019—
†K181407Artis zee/zeego & Artis Q/Q.zenSiemens Medical Solution USA, Inc.201859
†K122234Oec 9900 EliteGe Healthcare Surgery GE Oec Medical Systems, Inc.20126
†K132027Oec 9800 PlusGe Oec Medical Systems, Inc.20148

Also cleared against K202431: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K024012Oec 9800 E/CV+ Digital Mobile Imaging SystemGe Oec Medical Systems · 2003 · 6 generations back · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall
  • K021049Oec 9800 Plus Digital Mobile Imaging SystemGe Oec Medical Systems · 2002 · 6 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 2.3 years on median.
  • 7 of the 10 ancestors have a recall of any class; 2 have a Class I recall.
  • 1 other device also cites its predicate K202431.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

The ControlRad® Select Model Z with Siemens Artis zee is indicated to provide fluoroscopic imaging of the patient during diagnostic, surgical, and interventional procedures while reducing patients’ and clinicians' radiation exposure (Dose Area Product) outside of the ControlRad Select Model Z’s region of interest (ROI) as compared to Artis zee non-collimated image area. 1 The ControlRad Select Model Z semi-transparent filter should not be used in lieu of…

Read the full statement (549 words)

The ControlRad® Select Model Z with Siemens Artis zee is indicated to provide fluoroscopic imaging of the patient during diagnostic, surgical, and interventional procedures while reducing patients’ and clinicians' radiation exposure (Dose Area Product) outside of the ControlRad Select Model Z’s region of interest (ROI) as compared to Artis zee non-collimated image area. 1 The ControlRad Select Model Z semi-transparent filter should not be used in lieu of the Artis zee’s collimators, as they block the most radiation, but can help physicians balance dose reduction with the need to visualize structures outside the ROI when it is considered clinically advantageous to do so. Clinical applications may include cardiac angiography, neuro-angiography, general angiography, rotational angiography, multipurpose angiography and whole body radiographic/fluoroscopic procedures as well as procedures next to the table for i.e. patient extremities.

Additional procedures that can be performed include angiography in the operating room, image guided surgery by X-ray, by image fusion, and by navigation systems. The examination table as an integrated part of the system can be used for X-ray imaging, surgery and interventions.

1 Relative to open Field of View (FOV), the ControlRad® Select Model Z reduces at least 85% of the Dose Area Product at 65 kVp and ROI with width and length that are smaller than 1/5 the edge size of the full FOV.

The ControlRad® Trace Model 9, when used with OEC® 9900 Elite, is indicated to provide fluoroscopic and spot-film imaging of the patient during diagnostic, surgical, and interventional procedures while reducing patients and clinicians' radiation exposure (Dose Area Product) outside of the ControlRad® Trace’s region of interest (ROI) as compared to OEC® 9900 Elite non-collimated image area.1 The ControlRad® Trace semi-transparent filter should not be used in lieu of the OEC® 9900 Elite’s collimators, as they block the most radiation, but can help physicians balance dose reduction with the need to visualize structures outside the ROI when it is considered clinically advantageous to do so. Clinical applications may include cholangiography, endoscopic, urologic, orthopedic, neurologic, vascular, cardiac, critical care and emergency room procedures.

1 Relative to open Field of View (FOV), the ControlRad® Trace Model 9 reduces at least 50% of the Dose Area Product at 50 kVp and ROI with width and length that are smaller than 1/3 the diameter of the full FOV.

The ControlRad® Trace Model 8, when used with OEC® 9800/OEC® 9800 Plus, is indicated to provide fluoroscopic and spot-film imaging of the patient during diagnostic, surgical, and interventional procedures while reducing patients and clinicians' radiation exposure (Dose Area Product) outside of the ControlRad Trace’s region of interest (ROI) as compared to the OEC® 9800/OEC® 9800 Plus non-collimated image area.1 The ControlRad Trace semi-transparent filter should not be used in lieu of the OEC® 9800/OEC® 9800 Plus’ collimators, as they block the most radiation, but can help physicians balance dose reduction with the need to visualize structures outside the ROI when it is considered clinically advantageous to do so. Clinical applications may include cholangiography, endoscopic, urologic, orthopedic, neurologic, vascular, cardiac, critical care and emergency room procedures.

1 Relative to open Field of View (FOV), the ControlRad® Trace Model 8 reduces at least 50% of the Dose Area Product at 50 kVp and ROI with width and length that are smaller than 1/3 the diameter of the full FOV.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K211782: ControlRad Select Model Z, ControlRad Trace Model 8, ControlRad Trace Model 9.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211782

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026