510(k) Report

510(k) · Cleared

Recalled · Class I · 2026

Novum IQ Syringe Pump (40800BAXUS)

K242390510(k) SpecialCleared Sep 5, 202424-day reviewClass II21 CFR 880.5725Recalls 5 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corporation · FRN Pump, Infusion

Cleared on Sep 5, 2024 as substantially equivalent to K211125 (Baxter Healthcare Corporation, 2022) after a 24-day review. Its family tree reaches back 5 generations to 1994. 5 of the 14 devices in its family, counting itself, have a Class I recall. It has been recalled 5 times, including a Class I recall.

Decided
Sep 5, 2024
Review
24 days
Class
Class II
Product code
FRN
Recalls
5 (1 Class I)
Predicates
1

Its longest line of descent runs back 5 generations to K940147 (1994). 13 ancestors in all, the oldest K890120 (1989). No later device cites it as a predicate yet. 5 of the 14 devices in this family, counting this one, have a Class I recall.

  1. Root · 5 generations backK940147 Auto Syringe AS40A Infusion PumpBaxter Corp. · 1994 · Recalled
  2. 4 generations backK974332 Variable Pressure Syringe PumpAlaris Medical Systems, Inc. · 1998
  3. 3 generations backK023264 Medley Syringe Pump Module System, Model 8110Alaris Medical Systems, Inc. · 2002 · Recalled (Class I)
  4. 2 generations backK111386 Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2…Smiths Medical MD, Inc. · 2011 · Recalled (Class I)
  5. 1 generation backK211125 Novum IQ Syringe PumpBaxter Healthcare Corporation · 2022 · Recalled (Class I)
  6. This deviceK242390 Novum IQ Syringe Pump (40800BAXUS)Baxter Healthcare Corporation · 2024

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K940147Auto Syringe AS40A Infusion PumpBaxter Corp.19941
−4K974332Variable Pressure Syringe PumpAlaris Medical Systems, Inc.1998—
−3K023264Medley Syringe Pump Module System, Model 8110Alaris Medical Systems, Inc.2002Class I
−2K111386Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication…Smiths Medical MD, Inc.2011Class I
−1K211125Novum IQ Syringe PumpBaxter Healthcare Corporation2022Class I
0 (this device)K242390Novum IQ Syringe Pump (40800BAXUS)Baxter Healthcare Corporation2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199010
199510
199610
199910
200310
200411
200510
FIG. 1 — Lineage of K242390, 1994–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

5 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K211125Novum IQ Syringe Pump
Summary page 5
…fusion 880.5725 FRN, LZH 21 CFR 807.92(a)(3) | Legally Marketed Predicate Devices Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K211125 Novum 1Q Syringe Pump FRN Device Description Summary 21 CFR 807.92(a)(4) The Novum IQ Syringe Pump is a general purpose, syring…
Baxter Healthcare Corporation2022Class I

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (5 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 11, 2026Class IIZ-3065-2026Software designA software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains.
Aug 11, 2026Class IIZ-3066-2026Software designA software issue that may occur during a Volume/Time (VOT) multi-syringe infusion when a syringe reaches empty and is replaced while a Volume To Be Infused (VTBI) remains.
Aug 4, 2025Class IZ-2333-2025Software design (manufacturing process)Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false…
May 12, 2025Class IIZ-1964-2025Device DesignBaxter has identified a design issue which may cause the pump to detect the presence of a syringe flange when no syringe is loaded. When this issue occurs, the pumps 'user interface becomes stuck on the "Remove Syringe" screen when an…
Mar 3, 2025Class IIZ-1423-2025Process controlBaxter Healthcare Corporation is issuing an Urgent Medical Device Recall for the Novum IQ syringe pumps listed below due to an incorrectly installed gasket. A gasket failure could lead to potential fluid ingress due to cleaning, or as a…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K211125Novum IQ Syringe PumpBaxter Healthcare Corporation · 2022 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall
  • K111386Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication Safety Software and Supported…Smiths Medical MD, Inc. · 2011 · 2 generations back · ◆ on the line of descent in FIG. 16 Class I recalls
  • K040899Medex 3000 Series MR Syringe Infusion PumpMedex, Inc. · 2004 · 3 generations back · ◆ in the 2004 ancestors bar of FIG. 14 Class I recalls
  • K023264Medley Syringe Pump Module System, Model 8110Alaris Medical Systems, Inc. · 2002 · 3 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 30 years and passes through 4 companies; a new generation was cleared every 4.7 years on median.
  • 7 of the 13 ancestors have a recall of any class; 4 have a Class I recall.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The Novum I1Q Syringe Pump is intended to be used for the controlled administration of fluids. These include pharmaceutical drugs, parenteral nutrition, blood and blood products, and enteral nutrition. The Novum 1Q Syringe Pump is intended to deliver an infusion through the following clinically accepted routes of administration: intravenous, arterial, enteral and subcutaneous. The Novum 1Q Syringe Pump is intended to be used in conjunction with legally…

Read the full statement (178 words)

The Novum I1Q Syringe Pump is intended to be used for the controlled administration of fluids. These include

pharmaceutical drugs, parenteral nutrition, blood and blood products, and enteral nutrition.

The Novum 1Q Syringe Pump is intended to deliver an infusion through the following clinically accepted routes of

administration: intravenous, arterial, enteral and subcutaneous.

The Novum 1Q Syringe Pump is intended to be used in conjunction with legally marketed and compatible administration

sets, syringes, and medications provided by the user.

The Novum I1Q Syringe Pump is suitable for patient care in hospitals and outpatient health care facilities.

The Novum 1Q Syringe Pump is intended for use on adults, pediatrics and neonates.

The Novum I1Q Syringe Pump is intended to aid in the reduction of operator interaction through guided programming,

including a way to automate the programming of infusion parameters and documentation of infusion therapies when

integrated with an Electronic Medical Record (EMR) system. This automation is intended to aid in the reduction of

programming errors.

The Novum 1Q Syringe Pump is intended to be used by trained healthcare professionals.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K242390: Novum IQ Syringe Pump (40800BAXUS).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242390

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026