510(k) Report

510(k) · Cleared

Cleared

Revolution Vibe

K250941510(k) TraditionalCleared Aug 1, 2025126-day reviewClass II21 CFR 892.1750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ge Medical Systems, LLC · JAK System, X-Ray, Tomography, Computed

Cleared on Aug 1, 2025 as substantially equivalent to K213715 (Ge Medical Systems, LLC, 2021) after a 126-day review. Its family tree reaches back 10 generations to 2001.

Decided
Aug 1, 2025
Review
126 days
Class
Class II
Product code
JAK
Recalls
None
Predicates
1

Its longest line of descent runs back 10 generations to K013561 (2001). No later device cites it as a predicate yet.

Reference device: K183202 · Deep Learning Image Reconstruction · Ge Medical Systems, LLC · 2019Reference device: K213999 · Deep Learning Image Reconstruction · Ge Medical Systems, LLC · 2022Reference device: K201745 · Deep Learning Image Reconstruction for Gemstone Spectral Imaging · Ge Medical Systems, LLC · 2020Reference device: K203617 · MaxFOV 2 · Ge Medical Systems, LLC · 2021Reference device: K163213 · Revolution CT · Ge Medical Systems, LLC · 2016 · recalledReference device: K233750 · ECG-less Cardiac · Ge Medical Systems, LLC · 2024Reference device: K133640 · ASIR-V · Ge Medical Systems, LLC · 2014K013561 · Lightspeed 4.0 CT Scanner System · GE Medical Systems · 2001 · recalledK030420 · Lightspeed 5.0 Computed Tomography System · GE Medical Systems · 2003 · recalledK040372 · Lightspeed 7.0 CT Scanner System · Ge Medical Systems, LLC · 2004 · recalledK061817 · Lightspeed 7.1 CT Scanner System · Ge Medical Systems, LLC · 2006 · recalledK081105 · GE Lightspeed CT750 HD (Lightspeed 8.0) · GE Healthcare · 2008 · recalledK120833 · Discovery CT750 HD · Ge Medical Systems, LLC · 2012 · recalledK133705 · Revolution CT · Ge Medical Systems, LLC · 2014 · recalledK163213 · Revolution CT · Ge Medical Systems, LLC · 2016 · recalledK191777 · Revolution CT, Revolution CT ES, Revolution Apex, Revolution CT with Apex edition · Ge Medical Systems, LLC · 2019 · recalledK213715 · Revolution Apex, Revolution Apex Elite, Revolution Apex Plus, Revolution Apex Select,Revolution CT; Revolution CT ES; Revolution CT with Apex edition; Revolution CT ES with Apex edition · Ge Medical Systems, LLC · 2021 · recalled200020052010201520202025
  1. Root · 10 generations backK013561 Lightspeed 4.0 CT Scanner SystemGE Medical Systems · 2001 · Recalled
  2. 6 generations between
  3. 3 generations backK163213 Revolution CTGe Medical Systems, LLC · 2016 · Recalled
  4. 2 generations backK191777 Revolution CT, Revolution CT ES, Revolution Apex, Revolution CT with…Ge Medical Systems, LLC · 2019 · Recalled
  5. 1 generation backK213715 Revolution Apex, Revolution Apex Elite, Revolution Apex Plus…Ge Medical Systems, LLC · 2021 · Recalled
  6. This deviceK250941 Revolution VibeGe Medical Systems, LLC · 2025
Show all 10 generations
  1. Root · 10 generations backK013561 Lightspeed 4.0 CT Scanner SystemGE Medical Systems · 2001 · Recalled
  2. 9 generations backK030420 Lightspeed 5.0 Computed Tomography SystemGE Medical Systems · 2003 · Recalled
  3. 8 generations backK040372 Lightspeed 7.0 CT Scanner SystemGe Medical Systems, LLC · 2004 · Recalled
  4. 7 generations backK061817 Lightspeed 7.1 CT Scanner SystemGe Medical Systems, LLC · 2006 · Recalled
  5. 6 generations backK081105 GE Lightspeed CT750 HD (Lightspeed 8.0)GE Healthcare · 2008 · Recalled
  6. 5 generations backK120833 Discovery CT750 HDGe Medical Systems, LLC · 2012 · Recalled
  7. 4 generations backK133705 Revolution CTGe Medical Systems, LLC · 2014 · Recalled
  8. 3 generations backK163213 Revolution CTGe Medical Systems, LLC · 2016 · Recalled
  9. 2 generations backK191777 Revolution CT, Revolution CT ES, Revolution Apex, Revolution CT with…Ge Medical Systems, LLC · 2019 · Recalled
  10. 1 generation backK213715 Revolution Apex, Revolution Apex Elite, Revolution Apex Plus…Ge Medical Systems, LLC · 2021 · Recalled
  11. This deviceK250941 Revolution VibeGe Medical Systems, LLC · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K013561Lightspeed 4.0 CT Scanner SystemGE Medical Systems20015
−9K030420Lightspeed 5.0 Computed Tomography SystemGE Medical Systems20034
−8K040372Lightspeed 7.0 CT Scanner SystemGe Medical Systems, LLC20045
−7K061817Lightspeed 7.1 CT Scanner SystemGe Medical Systems, LLC20061
−6K081105GE Lightspeed CT750 HD (Lightspeed 8.0)GE Healthcare20085
−5K120833Discovery CT750 HDGe Medical Systems, LLC20121
−4K133705Revolution CTGe Medical Systems, LLC201414
−3K163213Revolution CTGe Medical Systems, LLC201616
−2K191777Revolution CT, Revolution CT ES, Revolution Apex, Revolution CT with Apex…Ge Medical Systems, LLC201918
−1K213715Revolution Apex, Revolution Apex Elite, Revolution Apex Plus, Revolution Apex…Ge Medical Systems, LLC202111
0 (this device)K250941Revolution VibeGe Medical Systems, LLC2025—
FIG. 1 — Lineage of K250941, 2001–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K213715Revolution Apex, Revolution Apex Elite, Revolution Apex Plus, Revolution Apex…
Summary page 6
…oduct Code: Predicate Device Information Device Name: Revolution Apex Elite Manufacturer: GE Medical Systems, LLC 510(k) Number: K213715, Cleared on December 17, 2021 Device Classification: Class II Regulation Number/ 21 CFR 892.1750 C…
Ge Medical Systems, LLC202111
†K183202Deep Learning Image ReconstructionGe Medical Systems, LLC2019—
†K213999Deep Learning Image ReconstructionGe Medical Systems, LLC2022—
†K201745Deep Learning Image Reconstruction for Gemstone Spectral ImagingGe Medical Systems, LLC2020—
†K203617MaxFOV 2Ge Medical Systems, LLC2021—
†K163213Revolution CTGe Medical Systems, LLC201616
†K233750ECG-less CardiacGe Medical Systems, LLC2024—
†K133640ASIR-VGe Medical Systems, LLC2014—

Also cleared against K213715: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 3 companies; a new generation was cleared every 2.4 years on median.
  • 10 of the 10 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K213715.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The system is intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission projection data from the same axial plane taken at different angles. The system may acquire data using Axial, Cine, Helical, Cardiac, and Gated CT scan techniques from patients of all ages. These images may be obtained either with or without contrast. This device may include signal analysis and display equipment, patient and equipment…

Read the full statement (356 words)

The system is intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission projection data from the same axial plane taken at different angles. The system may acquire data using Axial, Cine, Helical, Cardiac, and Gated CT scan techniques from patients of all ages. These images may be obtained either with or without contrast. This device may include signal analysis and display equipment, patient and equipment supports, components and accessories.

This device may include data and image processing to produce images in a variety of trans-axial and reformatted planes. Further, the images can be post processed to produce additional imaging planes or analysis results.

The system is indicated for head, whole body, cardiac, and vascular X-ray Computed Tomography applications.

The device output is a valuable medical tool for the diagnosis of disease, trauma, or abnormality and for planning, guiding, and monitoring therapy.

If the spectral imaging option is included on the system, the system can acquire CT images using different kV levels of the same anatomical region of a patient in a single rotation from a single source. The differences in the energy dependence of the attenuation coefficient of the different materials provide information about the chemical composition of body materials. This approach enables images to be generated at energies selected from the available spectrum to visualize and analyze information about anatomical and pathological structures.

GSI provides information of the chemical composition of renal calculi by calculation and graphical display of the spectrum of effective atomic number. GSI Kidney stone characterization provides additional information to aid in the characterization of uric acid versus non-uric acid stones. It is intended to be used as an adjunct to current standard methods for evaluating stone etiology and composition.

The CT system is indicated for low dose CT for lung cancer screening. The screening must be performed within the established inclusion criteria of programs/ protocols that have been approved and published by either a governmental body or professional medical society.

*Please refer to clinical literature, including the results of the National Lung Screening Trial (N Engl J Med 2011; 365:395-409) and subsequent literature, for further information

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K250941: Revolution Vibe.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K250941

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026