510(k) Report

510(k) · Cleared

Cleared

Self-Propelled CT Scan Base Kit, CGBA-035A; Alphenix, INFX-8000C/B, INFX-8000C/S, V9.6 with Calculated DAP

K251645510(k) TraditionalCleared Sep 26, 2025120-day reviewClass II21 CFR 892.1750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Canon Medical Systems Corporation · JAK System, X-Ray, Tomography, Computed

Cleared on Sep 26, 2025 as substantially equivalent to K182223 (Canon Medical Systems, USA, 2018) and 2 other predicates after a 120-day review. Its family tree reaches back 20 generations to 1991.

Decided
Sep 26, 2025
Review
120 days
Class
Class II
Product code
JAK
Recalls
None
Predicates
3

Its longest line of descent runs back 20 generations to K913770 (1991). 208 ancestors in all, the oldest K871859 (1987). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2021: 2 other ancestors2018: 3 other ancestors2015: 5 other ancestors2016: 3 other ancestors2014: 3 other ancestors2011: 4 other ancestors2013: 2 other ancestors2012: 5 other ancestors2008: 3 other ancestors2020: 1 other ancestor2005: 10 other ancestors2019: 2 other ancestors2003: 15 other ancestors2002: 19 other ancestors2001: 17 other ancestors1998: 9 other ancestors2000: 12 other ancestors1995: 7 other ancestors1994: 4 other ancestors2017: 1 other ancestor2010: 2 other ancestors2006: 8 other ancestors1993: 4 other ancestors1989: 2 other ancestors2009: 2 other ancestors2007: 4 other ancestors2004: 13 other ancestors1990: 2 other ancestors1999: 5 other ancestors1997: 6 other ancestors1996: 6 other ancestors1992: 2 other ancestors1987: 1 other ancestor1991: 4 other ancestorsReference device: K213504 · Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2022K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002×2: 2 generations cleared close together, K032748 (2003), K040305 (2004) K043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK071331 · Vitrea Version 4.0 · Vital Images, Inc. · 2007 · recalledK073156 · Qplaque MR · Medis Medical Imaging Systems BV · 2008K120636 · Synapse 3D Cardiac Tools · Fujifilm Medical System U.S.A., Inc. · 2012K171222 · Vitrea Software Toshiba Package; VSTP-001A · Toshibamedical Systems Corporation · 2017K173088 · Vitrea Software Toshiba Package VSTP-001A · Toshibamedical Systems Corporation · 2018K183013 · Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2018K192923 · Vitrea Software Package · Canon Medical Systems Corporation · 2020K203312 · Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2021K213504 · Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2022K232835 · Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction System · Canon Medical Systems Corporation · 2024K242403 · Aquilion ONE (TSX-308A/3) V1.5 · Canon Medical Systems Corporation · 20241990200020102020
Other ancestors, by generation 1 generation back: 2 other ancestors2 generations back: 2 other ancestors3 generations back: 4 other ancestors4 generations back: 5 other ancestors5 generations back: 6 other ancestors6 generations back: 7 other ancestors7 generations back: 10 other ancestors8 generations back: 13 other ancestors9 generations back: 16 other ancestors10 generations back: 28 other ancestors11 generations back: 32 other ancestors12 generations back: 27 other ancestors13 generations back: 16 other ancestors14 generations back: 15 other ancestors15 generations back: 3 other ancestors16 generations back: 2 other ancestors K242403 · Aquilion ONE (TSX-308A/3) V1.5 · Canon Medical Systems Corporation · 2024K232835 · Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction System · Canon Medical Systems Corporation · 2024K213504 · Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2022K203312 · Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2021K192923 · Vitrea Software Package · Canon Medical Systems Corporation · 2020K183013 · Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2018K173088 · Vitrea Software Toshiba Package VSTP-001A · Toshibamedical Systems Corporation · 2018K171222 · Vitrea Software Toshiba Package; VSTP-001A · Toshibamedical Systems Corporation · 2017K120636 · Synapse 3D Cardiac Tools · Fujifilm Medical System U.S.A., Inc. · 2012K073156 · Qplaque MR · Medis Medical Imaging Systems BV · 2008K071331 · Vitrea Version 4.0 · Vital Images, Inc. · 2007 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK040305 · VITREA2 Version 3.5 · Vital Images, Inc. · 2004K032748 · VITREA2, Version 3.4 Medical Image Processing Software · Vital Images, Inc. · 2003 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991−20−15−10−50
  1. Root · 20 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 16 generations between
  3. 3 generations backK213504 Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System…Canon Medical Systems Corporation · 2022
  4. 2 generations backK232835 Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction SystemCanon Medical Systems Corporation · 2024
  5. 1 generation backK242403 Aquilion ONE (TSX-308A/3) V1.5Canon Medical Systems Corporation · 2024
  6. This deviceK251645 Self-Propelled CT Scan Base Kit, CGBA-035A; Alphenix, INFX-8000C/B…Canon Medical Systems Corporation · 2025
Show all 20 generations
  1. Root · 20 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 19 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 18 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 17 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 16 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 15 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 14 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 13 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  9. 12 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  10. 11 generations backK071331 Vitrea Version 4.0Vital Images, Inc. · 2007 · Recalled
  11. 10 generations backK073156 Qplaque MRMedis Medical Imaging Systems BV · 2008
  12. 9 generations backK120636 Synapse 3D Cardiac ToolsFujifilm Medical System U.S.A., Inc. · 2012
  13. 8 generations backK171222 Vitrea Software Toshiba Package; VSTP-001AToshibamedical Systems Corporation · 2017
  14. 7 generations backK173088 Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation · 2018
  15. 6 generations backK183013 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2018
  16. 5 generations backK192923 Vitrea Software PackageCanon Medical Systems Corporation · 2020
  17. 4 generations backK203312 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2021
  18. 3 generations backK213504 Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System…Canon Medical Systems Corporation · 2022
  19. 2 generations backK232835 Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction SystemCanon Medical Systems Corporation · 2024
  20. 1 generation backK242403 Aquilion ONE (TSX-308A/3) V1.5Canon Medical Systems Corporation · 2024
  21. This deviceK251645 Self-Propelled CT Scan Base Kit, CGBA-035A; Alphenix, INFX-8000C/B…Canon Medical Systems Corporation · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−20K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−19K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−18K020483Advantage Workstation 4.1GE Medical Systems20022
−17K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−16K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−15K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−14K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−13K052632VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc.20052
−12K061624Vitrea, Version 3.9Vital Images, Inc.20061
−11K071331Vitrea Version 4.0Vital Images, Inc.20071
−10K073156Qplaque MRMedis Medical Imaging Systems BV2008—
−9K120636Synapse 3D Cardiac ToolsFujifilm Medical System U.S.A., Inc.2012—
−8K171222Vitrea Software Toshiba Package; VSTP-001AToshibamedical Systems Corporation2017—
−7K173088Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation2018—
−6K183013Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation2018—
−5K192923Vitrea Software PackageCanon Medical Systems Corporation2020—
−4K203312Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation2021—
−3K213504Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software…Canon Medical Systems Corporation2022—
−2K232835Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction SystemCanon Medical Systems Corporation2024—
−1K242403Aquilion ONE (TSX-308A/3) V1.5Canon Medical Systems Corporation2024—
0 (this device)K251645Self-Propelled CT Scan Base Kit, CGBA-035A; Alphenix, INFX-8000C/B…Canon Medical Systems Corporation2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198920
199020
199140
199220
199340
199440
199570
199660
199760
199890
199950
2000120
2001170
2002190
2003150
2004130
2005100
200680
200740
200830
200920
201020
201140
201250
201320
201430
201550
201630
201710
201830
201920
202010
202120
FIG. 1 — Lineage of K251645, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K182223Aquilion ONE Self-Propelled Scan Base Kit for IVR-CT, CGBA-034A
Summary page 6
…Medical 21 CFR September for IVR-CT, tomography JAK K182223 Systems 892.1750 14, 2018 CGBA-034A…
Canon Medical Systems, USA2018—
*K242403Aquilion ONE (TSX-308A/3) V1.5
Summary page 6
…Medical 21 CFR December V1.5 tomography JAK K242403 Systems 892.1750 23, 2024 (Secondary…
Canon Medical Systems Corporation2024—
*K210900Alphenix, INFX-8000C/B, INFX-8000C/S, V9.2
Summary page 7
…INFX-8000C/S, V9.6 with Calculated INFX-8000C/S, V9.2 DAP (Modified as K210900) Gantry tilting Max. +/-30° Max. +/-28° Gantry movement High speed 130…
Canon Medical Systems Corporation20217
†K213504Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package…Canon Medical Systems Corporation2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 8 companies; a new generation was cleared every 11 months on median.
  • 68 of the 208 ancestors have a recall of any class.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The movable gantry base unit allows the Aquilion ONE (TSX-308A) system to be installed in the same procedure room as the INFX-8000C system, enabling coordinated clinical use within a shared workspace. This configuration provides longitudinal positioning along the z-axis for image acquisition. This device is a digital radiography/fluoroscopy system used in a diagnostic and interventional angiography configuration. The system is indicated for use in…

Read the full statement (156 words)

The movable gantry base unit allows the Aquilion ONE (TSX-308A) system to be installed in the same procedure room as the INFX-8000C system, enabling coordinated clinical use within a shared workspace. This configuration provides longitudinal positioning along the z-axis for image acquisition.

This device is a digital radiography/fluoroscopy system used in a diagnostic and interventional angiography configuration. The system is indicated for use in diagnostic and angiographic procedures for blood vessels in the heart, brain, abdomen and lower extremities. The Calculated Dose Area Product (DAP) feature provides an alternative method for determining dose metrics without the use of a physical area dosimeter. This function estimates the cumulative reference air kerma, reference air kerma rate, and cumulative dose area product based on system parameters, including X-ray exposure settings, beam hardening filter configuration, beam limiting device position, and region of interest (ROI) filter status. The calculation method is calibration-dependent, with accuracy contingent upon periodic calibration against reference measurements.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K251645: Self-Propelled CT Scan Base Kit, CGBA-035A; Alphenix, INFX-8000C/B, INFX-8000C/S, V9.6 with Calculated DAP.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K251645

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026