510(k) Report

510(k) · Cleared

Recalled · 2002

Blease 6200 Anaesthesia Ventilator

K982132510(k) TraditionalCleared Apr 15, 1999302-day reviewClass II21 CFR 868.5895Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Blease Medical Equipment, Ltd. · CBK Ventilator, Continuous, Facility Use

Cleared on Apr 15, 1999 after a 302-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 2 of the 6 devices in its family, counting itself, have a Class I recall. 5 later devices descend from it. It has been recalled once.

Decided
Apr 15, 1999
Review
302 days
Class
Class II
Product code
CBK
Recalls
1
Predicates
0

5 later devices descend from it, 1 citing it directly. 2 of the 6 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2004: 1 descendant cleared2005: 1 descendant cleared2011: 1 descendant cleared, 1 with a Class I recall12012: 2 descendants cleared, 1 with a Class I recall11995200020052010201520202025
  1. This deviceK982132 Blease 6200 Anaesthesia VentilatorBlease Medical Equipment, Ltd. · 1999
  2. Descendant · cites it directly · 4 of its ownK041430 Blease Sirius Anesthesia System, Models 3000 and 2000Blease Medical Equipment, Ltd. · 2004
  3. Descendant · 2 generations on · 3 of its ownK051629 Bleas Esiriuc Anaesthsia System, Models 3000, 2000Blease USA, Inc. · 2005 · Recalled
  4. Descendant · 3 generations on · 2 of its ownK101850 Spacelabs Bleasesirius Anesthesia WorkstationSpacelabs Healthcare, Ltd. · 2011 · Recalled (Class I)
  5. Descendant · 4 generations on · 0 of its ownK112729 BLEASE700/900 Series VentilatorsSpacelabs Healthcare · 2012 · Recalled
  6. Descendant · 4 generations on · 0 of its ownK113051 Spacelabs Arkon Anesthesia WorkstationSpacelabs Healthcare · 2012 · Recalled (Class I)

Class I recalls in this family

Most influential descendants

Showing 5 of 5 · See all
  • K041430Blease Sirius Anesthesia System, Models 3000 and 2000Blease Medical Equipment, Ltd. · 2004 · cites it directly4descendants
  • K051629Bleas Esiriuc Anaesthsia System, Models 3000, 2000Blease USA, Inc. · 2005 · 2 generations on3descendants
  • K101850Spacelabs Bleasesirius Anesthesia WorkstationSpacelabs Healthcare, Ltd. · 2011 · 3 generations on2descendants
  • K112729BLEASE700/900 Series VentilatorsSpacelabs Healthcare · 2012 · 4 generations on0descendants
  • K113051Spacelabs Arkon Anesthesia WorkstationSpacelabs Healthcare · 2012 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K982132Blease 6200 Anaesthesia VentilatorBlease Medical Equipment, Ltd.1999—
+1K041430Blease Sirius Anesthesia System, Models 3000 and 2000Blease Medical Equipment, Ltd.2004—
+2K051629Bleas Esiriuc Anaesthsia System, Models 3000, 2000Blease USA, Inc.20053
+3K101850Spacelabs Bleasesirius Anesthesia WorkstationSpacelabs Healthcare, Ltd.2011Class I
+4K112729BLEASE700/900 Series VentilatorsSpacelabs Healthcare20121
+4K113051Spacelabs Arkon Anesthesia WorkstationSpacelabs Healthcare2012Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200510
201111
201221
FIG. 1 — Lineage of K982132, 1999–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (5)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K041430Blease Sirius Anesthesia System, Models 3000 and 2000Blease Medical Equipment, Ltd.20044

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 31, 2002Not classifiedZ-0165-04OtherAssay may produce falsely low IgM results without error codes when testing specimens contain elevated serum paraproteins associated with various myeloma or other malignancies.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K101850Spacelabs Bleasesirius Anesthesia WorkstationSpacelabs Healthcare, Ltd. · 2011 · 3 generations on · ◆ in the 2011 descendants bar of FIG. 11 Class I recall
  • K113051Spacelabs Arkon Anesthesia WorkstationSpacelabs Healthcare · 2012 · 4 generations on · ◆ in the 2012 descendants bar of FIG. 13 Class I recalls

What does this lineage say?

  • Of its descendants, K041430 (Blease Medical Equipment, Ltd., 2004) has gone furthest, with 4 descendants of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The Blease 6200 anaesthesia ventilator is an advanced microprocessor controlled, pneumatically driven ventilator (controller) specifically designed for mechanical ventilation of adult and paediatric patients under general anaesthesia.

It is designed for use with a circle type absorber and is ideally suited to both low-flow and high-flow applications. The ventilator may also be used with either a Bain-type coaxial circuit or a Jackson-Rees/Ayres T-piece type paediatric circuit with no modification being necessary.

The device is intended for use only by a suitably qualified physician.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982132: Blease 6200 Anaesthesia Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K982132

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026