510(k) Report

510(k) · Cleared

Cleared

Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion Kit

K023098510(k) TraditionalCleared Dec 9, 200282-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mckinley Infuser · MEB Pump, Infusion, Elastomeric

Cleared on Dec 9, 2002 as substantially equivalent to K013928 (Breg, Inc., 2001) and 2 other predicates after an 82-day review. Its family tree reaches back 5 generations to 1990. 1 of the 34 devices in its family, counting itself, has a Class I recall. 17 later devices descend from it.

Decided
Dec 9, 2002
Review
82 days
Class
Class II
Product code
MEB
Recalls
None
Predicates
3

Its longest line of descent runs back 5 generations to K896422 (1990). 16 ancestors in all, the oldest K884505 (1989). 17 later devices descend from it, 3 citing it directly. 1 of the 34 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2001: 2 other ancestors1999: 3 other ancestors1995: 2 other ancestors1993: 1 other ancestor1998: 1 other ancestor1990: 1 other ancestor1989: 1 other ancestor2003: 2 descendants cleared2006: 3 descendants cleared2004: 2 descendants cleared2005: 4 descendants cleared2009: 1 descendant cleared2008: 1 descendant cleared, 1 with a Class I recall12016: 1 descendant cleared2024: 2 descendants cleared2026: 1 descendant clearedK896422 · Burron Ambulatory Drug Delivery System · Burron Medical, Inc. · 1990K980558 · Painbuster Infusion System · I-Flow Corp. · 1998×2: 2 generations cleared close together, K982946 (1998), K984502 (1999) K020862 · I-Flow Elastomeric Pump · I-Flow Corp. · 2002 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 4 other ancestors3 generations back: 5 other ancestors 1 generation forward: 3 descendants2 generations forward: 4 descendants3 generations forward: 4 descendants4 generations forward: 2 descendants, 1 with a Class I recall15 generations forward: 1 descendant6 generations forward: 3 descendants K020862 · I-Flow Elastomeric Pump · I-Flow Corp. · 2002 · recalledK984502 · Nerve Block Infusion Kit · I-Flow Corp. · 1999K982946 · Painbuster Infusion Kit · I-Flow Corp. · 1998K980558 · Painbuster Infusion System · I-Flow Corp. · 1998K896422 · Burron Ambulatory Drug Delivery System · Burron Medical, Inc. · 1990−50+5
  1. Root · 5 generations backK896422 Burron Ambulatory Drug Delivery SystemBurron Medical, Inc. · 1990
  2. 4 generations backK980558 Painbuster Infusion SystemI-Flow Corp. · 1998
  3. 3 generations backK982946 Painbuster Infusion KitI-Flow Corp. · 1998
  4. 2 generations backK984502 Nerve Block Infusion KitI-Flow Corp. · 1999
  5. 1 generation backK020862 I-Flow Elastomeric PumpI-Flow Corp. · 2002 · Recalled
  6. This deviceK023098 Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser…Mckinley Infuser · 2002
  7. Descendant · cites it directly · 15 of its ownK033039 Modification to: Accufuser, Accufuser Plus, Standard Procedure KitsMckinley, Inc. · 2003
  8. Descendant · cites it directly · 8 of its ownK032642 Beeline SystemMckinley, Inc. · 2003
  9. Descendant · 2 generations on · 7 of its ownK042228 Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004
  10. Descendant · 3 generations on · 6 of its ownK050770 Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005
  11. Descendant · 4 generations on · 5 of its ownK052451 MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005

Showing 5 of 17 descendants. See all descendants

Descendants cleared per year

2003: 22004: 22005: 42006: 32008: 12009: 12016: 12024: 22026: 1
2003high 4 (2005) · low 0 (2007)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 17 · See all
  • K033039Modification to: Accufuser, Accufuser Plus, Standard Procedure KitsMckinley, Inc. · 2003 · cites it directly15descendants
  • K032642Beeline SystemMckinley, Inc. · 2003 · cites it directly8descendants
  • K042228Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004 · 2 generations on7descendants
  • K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005 · 3 generations on6descendants
  • K052451MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005 · 4 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K896422Burron Ambulatory Drug Delivery SystemBurron Medical, Inc.1990—
−4K980558Painbuster Infusion SystemI-Flow Corp.1998—
−3K982946Painbuster Infusion KitI-Flow Corp.1998—
−2K984502Nerve Block Infusion KitI-Flow Corp.1999—
−1K020862I-Flow Elastomeric PumpI-Flow Corp.20021
0 (this device)K023098Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion KitMckinley Infuser2002—
+1K033039Modification to: Accufuser, Accufuser Plus, Standard Procedure KitsMckinley, Inc.2003—
+1K032642Beeline SystemMckinley, Inc.2003—
+2K042228Beeline Motiv, Propolis, PcaMckinley, Inc.2004—
+3K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC2005—
+4K052451MPS Acacia Medflo Elastomeric PumpMps Acacia2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199010
199310
199520
199810
199930
200120

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200320
200420
200540
200630
200811
200910
201610
202420
202610
FIG. 1 — Lineage of K023098, 1990–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MEB device

  1. #1 K250234 SMARTeZ™ Elastomeric Infusion Pump (RS series)score 14.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013928Pain Care 3200
Summary page 2
…rocode: MEB Existing Device Cleared 510(k): K003915, Accufuser and Accufuser Plus Predicate devices demonstrating substantial equivalence include the following. K013928, Breg Corporation, Pain Care 3000 and 3200, and accessory Kit. K014091, Stryker Pain Pump and Accessory Kit. K02086…
Breg, Inc.2001—
*K014091Stryker Painpump
Summary page 2
…Plus Predicate devices demonstrating substantial equivalence include the following. K013928, Breg Corporation, Pain Care 3000 and 3200, and accessory Kit. K014091, Stryker Pain Pump and Accessory Kit. K020862, I-Flow, Infusion Pump and Administration Set. Submitted by: McKinley…
Stryker Corp.2001—
*K020862I-Flow Elastomeric Pump
Summary page 2
…ivalence include the following. K013928, Breg Corporation, Pain Care 3000 and 3200, and accessory Kit. K014091, Stryker Pain Pump and Accessory Kit. K020862, I-Flow, Infusion Pump and Administration Set. Submitted by: McKinley Infuser, LLC 63 1 Howard, #202 San Fran…
I-Flow Corp.20021

What descends from it? (17)

See all 17

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K033039Modification to: Accufuser, Accufuser Plus, Standard Procedure KitsMckinley, Inc.200315
K032642Beeline SystemMckinley, Inc.20038
K053226Zimmer Ambulatory Pump Pain Management Systems with Fenestrated Catheter and Flow SplitterZimmer, Inc.20060

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · 4 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 12 years and passes through 3 companies; a new generation was cleared every 8 months on median.
  • 4 of the 16 ancestors have a recall of any class.
  • Of its descendants, K033039 (Mckinley, Inc., 2003) has gone furthest, with 15 descendants of its own.

How does its category compare?

All MEB devices

MEB Pump, Infusion, Elastomeric: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MEB

2in 2024

2007: 52008: 22009: 12013: 12014: 12016: 12019: 12024: 22026 (partial year): 1
2007high 5 (2007) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MEB

42in 2007

2007: 42 days median
2007high 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MEB

17in 2018

2007: 12008: 32009: 482010: 22011: 8, 1 Class I2013: 2, 1 Class I2018: 17
2007high 48 (2009) · low 0 (2012)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · MEB

1,408in 2025

2007: 1102008: 4442009: 7982010: 1,8272011: 2,2652012: 1,9762013: 1,9562014: 2,6952015: 2,9802016: 2,1472017: 1,6532018: 1,4732019: 9742020: 2,7322021: 1,8022022: 1,2882023: 1,2482024: 1,4242025: 1,408
2007high 2,980 (2015) · low 110 (2007)2025

MAUDE reports naming product code MEB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075421110
20082—3444
20091—48798
20100—21,827
20110—8 (1)2,265
20120—01,976
20131—2 (1)1,956
20141—02,695
20150—02,980
20161—02,147
20170—01,653
20180—171,473
20191—0974
20200—02,732
20210—01,802
20220—01,288
20230—01,248
20242—01,424
20250—01,408
20261—0—

What is it indicated for?

The Accufuser and Accufuser Plus systems are intended for general infusion use. Routes of infusion include intravenous, percutaneous, subcutaneous, intra-arterial and epidural, and into the intra-operative (soft tissue / body cavity) site. The Accuhser Plus is also intended for patient-controlled infusion using the integrated bolus button. General infusion uses include pain management for preoperative, perioperative and postoperative surgery. The…

Read the full statement (134 words)

The Accufuser and Accufuser Plus systems are intended for general infusion use. Routes of infusion include intravenous, percutaneous, subcutaneous, intra-arterial and epidural, and into the intra-operative (soft tissue / body cavity) site. The Accuhser Plus is also intended for patient-controlled infusion using the integrated bolus button. General infusion uses include pain management for preoperative, perioperative and postoperative surgery.

The Accufuser and Accufuser Plus systems are also intended for continuous and/or intermittent delivery of medication (such as local anesthetics or narcotics) to surgical wound sites and/or close proximity to nerves for preoperative, perioperative and postoperative regional anesthesia and pain management. Routes of administration may be intraoperative, perineural or percutaneous.

The Accufuser/Accufuser Plus system is suitable for use as an ambulatory device and is intended for use in the hospital, home environment or alternative care sites.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K023098: Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K023098

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026