510(k) Report

510(k) · Cleared

Cleared

Beeline System

K032642510(k) SpecialCleared Sep 23, 200327-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mckinley, Inc. · FRN Pump, Infusion

Cleared on Sep 23, 2003 as substantially equivalent to K990461 (Mckinley, Inc., 1999) and 1 other predicate after a 27-day review. Its family tree reaches back 6 generations to 1990. 1 of the 27 devices in its family, counting itself, has a Class I recall. 8 later devices descend from it.

Decided
Sep 23, 2003
Review
27 days
Class
Class II
Product code
FRN
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K896422 (1990). 18 ancestors in all, the oldest K884505 (1989). 8 later devices descend from it, 1 citing it directly. 1 of the 27 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1999: 4 other ancestors2001: 2 other ancestors1995: 2 other ancestors1993: 1 other ancestor1998: 1 other ancestor1990: 1 other ancestor1989: 1 other ancestor2004: 1 descendant cleared2005: 2 descendants cleared2008: 1 descendant cleared, 1 with a Class I recall12016: 1 descendant cleared2024: 2 descendants cleared2026: 1 descendant clearedK896422 · Burron Ambulatory Drug Delivery System · Burron Medical, Inc. · 1990K980558 · Painbuster Infusion System · I-Flow Corp. · 1998×2: 2 generations cleared close together, K982946 (1998), K984502 (1999) K020862 · I-Flow Elastomeric Pump · I-Flow Corp. · 2002 · recalledK023098 · Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion Kit · Mckinley Infuser · 20021990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors3 generations back: 4 other ancestors4 generations back: 5 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 2 descendants, 1 with a Class I recall14 generations forward: 1 descendant5 generations forward: 3 descendants K023098 · Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion Kit · Mckinley Infuser · 2002K020862 · I-Flow Elastomeric Pump · I-Flow Corp. · 2002 · recalledK984502 · Nerve Block Infusion Kit · I-Flow Corp. · 1999K982946 · Painbuster Infusion Kit · I-Flow Corp. · 1998K980558 · Painbuster Infusion System · I-Flow Corp. · 1998K896422 · Burron Ambulatory Drug Delivery System · Burron Medical, Inc. · 1990−50+5
  1. Root · 6 generations backK896422 Burron Ambulatory Drug Delivery SystemBurron Medical, Inc. · 1990
  2. 5 generations backK980558 Painbuster Infusion SystemI-Flow Corp. · 1998
  3. 4 generations backK982946 Painbuster Infusion KitI-Flow Corp. · 1998
  4. 3 generations backK984502 Nerve Block Infusion KitI-Flow Corp. · 1999
  5. 2 generations backK020862 I-Flow Elastomeric PumpI-Flow Corp. · 2002 · Recalled
  6. 1 generation backK023098 Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser…Mckinley Infuser · 2002
  7. This deviceK032642 Beeline SystemMckinley, Inc. · 2003
  8. Descendant · cites it directly · 7 of its ownK042228 Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004
  9. Descendant · 2 generations on · 6 of its ownK050770 Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005
  10. Descendant · 3 generations on · 5 of its ownK052451 MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005
  11. Descendant · 3 generations on · 4 of its ownK081905 Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · Recalled (Class I)
  12. Descendant · 4 generations on · 3 of its ownK151650 SMARTez elastomeric infusion pumpEpic Medical Pte., Ltd. · 2016

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2004: 12005: 22008: 12016: 12024: 22026: 1
2004high 2 (2005) · low 0 (2006)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 8 · See all
  • K042228Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004 · cites it directly7descendants
  • K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005 · 2 generations on6descendants
  • K052451MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005 · 3 generations on5descendants
  • K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · 3 generations on4descendants
  • K151650SMARTez elastomeric infusion pumpEpic Medical Pte., Ltd. · 2016 · 4 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K896422Burron Ambulatory Drug Delivery SystemBurron Medical, Inc.1990—
−5K980558Painbuster Infusion SystemI-Flow Corp.1998—
−4K982946Painbuster Infusion KitI-Flow Corp.1998—
−3K984502Nerve Block Infusion KitI-Flow Corp.1999—
−2K020862I-Flow Elastomeric PumpI-Flow Corp.20021
−1K023098Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion KitMckinley Infuser2002—
0 (this device)K032642Beeline SystemMckinley, Inc.2003—
+1K042228Beeline Motiv, Propolis, PcaMckinley, Inc.2004—
+2K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC2005—
+3K052451MPS Acacia Medflo Elastomeric PumpMps Acacia2005—
+3K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc.2008Class I
+4K151650SMARTez elastomeric infusion pumpEpic Medical Pte., Ltd.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199010
199310
199520
199810
199940
200120

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200520
200811
201610
202420
202610
FIG. 1 — Lineage of K032642, 1990–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K990461Mckinley SP Disposable Infusion Pump
Summary page 1
…on of procedure kits. 5.2 The original cleared device demonstrating substantial equivalence is the McKinley Spring Pump Disposable Infusion Pump (K99046 1). Special 5 10(k) McKinley Beeline System Page 15 of 91 5.3 A…
Mckinley, Inc.1999—
*K023098Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion Kit
Summary page 2
…2 === 5.3 A supporting predicate device also demonstrating substantial equivalence is McKinley’s Accufuser, Accufuser Plus & standard procedure kit (K023098). 5.4 The cleared indications for use for the Beeline system are as follows: The Beeline system is indicated…
Mckinley Infuser2002—

What descends from it? (8)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K042228Beeline Motiv, Propolis, PcaMckinley, Inc.20047

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · 3 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 13 years and passes through 4 companies; a new generation was cleared every 9 months on median.
  • 4 of the 18 ancestors have a recall of any class.
  • Of its descendants, K042228 (Mckinley, Inc., 2004) has gone furthest, with 7 descendants of its own.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The Beeline system is indicated for intravenous, intra-arterial, enteral, subcutaneous and epidural infusion of medications or fluids requiring continuous delivery at controlled infusion rates.

The Beeline system is also intended to provide continuous infusion of a local anesthetic directly into the intraoperative site for postoperative pain management.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K032642: Beeline System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032642

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026