Mckinley, Inc. · FRN Pump, Infusion
Cleared on Sep 23, 2003 as substantially equivalent to K990461 (Mckinley, Inc., 1999) and 1 other predicate after a 27-day review. Its family tree reaches back 6 generations to 1990. 1 of the 27 devices in its family, counting itself, has a Class I recall. 8 later devices descend from it.
- Decided
- Sep 23, 2003
- Review
- 27 days
- Class
- Class II
- Product code
- FRN
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 6 generations to K896422 (1990). 18 ancestors in all, the oldest K884505 (1989). 8 later devices descend from it, 1 citing it directly. 1 of the 27 devices in this family, counting this one, has a Class I recall.
- Root · 6 generations backK896422 Burron Ambulatory Drug Delivery SystemBurron Medical, Inc. · 1990
- 5 generations backK980558 Painbuster Infusion SystemI-Flow Corp. · 1998
- 4 generations backK982946 Painbuster Infusion KitI-Flow Corp. · 1998
- 3 generations backK984502 Nerve Block Infusion KitI-Flow Corp. · 1999
- 2 generations backK020862 I-Flow Elastomeric PumpI-Flow Corp. · 2002 · Recalled
- 1 generation backK023098 Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser…Mckinley Infuser · 2002
- This deviceK032642 Beeline SystemMckinley, Inc. · 2003
- Descendant · cites it directly · 7 of its ownK042228 Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004
- Descendant · 2 generations on · 6 of its ownK050770 Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005
- Descendant · 3 generations on · 5 of its ownK052451 MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005
- Descendant · 3 generations on · 4 of its ownK081905 Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · Recalled (Class I)
- Descendant · 4 generations on · 3 of its ownK151650 SMARTez elastomeric infusion pumpEpic Medical Pte., Ltd. · 2016
Showing 5 of 8 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
- K081905 Accuflow and Accuflux Elastomeric Infusion Pump3 generations on · 2008
Most influential descendants
Showing 5 of 8 · See all- K042228Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004 · cites it directly7descendants
- K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005 · 2 generations on6descendants
- K052451MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005 · 3 generations on5descendants
- K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · 3 generations on4descendants
- K151650SMARTez elastomeric infusion pumpEpic Medical Pte., Ltd. · 2016 · 4 generations on3descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K896422 | Burron Ambulatory Drug Delivery System | Burron Medical, Inc. | 1990 | — |
| −5 | K980558 | Painbuster Infusion System | I-Flow Corp. | 1998 | — |
| −4 | K982946 | Painbuster Infusion Kit | I-Flow Corp. | 1998 | — |
| −3 | K984502 | Nerve Block Infusion Kit | I-Flow Corp. | 1999 | — |
| −2 | K020862 | I-Flow Elastomeric Pump | I-Flow Corp. | 2002 | 1 |
| −1 | K023098 | Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion Kit | Mckinley Infuser | 2002 | — |
| 0 (this device) | K032642 | Beeline System | Mckinley, Inc. | 2003 | — |
| +1 | K042228 | Beeline Motiv, Propolis, Pca | Mckinley, Inc. | 2004 | — |
| +2 | K050770 | Modification to Accufuser, Accufuser Plus Standard Procedure Kit | Mckinley Medical, LLC | 2005 | — |
| +3 | K052451 | MPS Acacia Medflo Elastomeric Pump | Mps Acacia | 2005 | — |
| +3 | K081905 | Accuflow and Accuflux Elastomeric Infusion Pump | Westmed, Inc. | 2008 | Class I |
| +4 | K151650 | SMARTez elastomeric infusion pump | Epic Medical Pte., Ltd. | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1989 | 1 | 0 |
| 1990 | 1 | 0 |
| 1993 | 1 | 0 |
| 1995 | 2 | 0 |
| 1998 | 1 | 0 |
| 1999 | 4 | 0 |
| 2001 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
| 2005 | 2 | 0 |
| 2008 | 1 | 1 |
| 2016 | 1 | 0 |
| 2024 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRN device
- #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K990461 | Mckinley SP Disposable Infusion PumpSummary page 1…on of procedure kits. 5.2 The original cleared device demonstrating substantial equivalence is the McKinley Spring Pump Disposable Infusion Pump (K99046 1). Special 5 10(k) McKinley Beeline System Page 15 of 91 5.3 A… | 1999 |
| * | K023098 | Accufuser, Accufuser Plus, Standard Procedure Kit, Accufuser Infusion KitSummary page 2…2 === 5.3 A supporting predicate device also demonstrating substantial equivalence is McKinley’s Accufuser, Accufuser Plus & standard procedure kit (K023098). 5.4 The cleared indications for use for the Beeline system are as follows: The Beeline system is indicated… | 2002 |
What descends from it? (8)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K042228 | Beeline Motiv, Propolis, Pca | 2004 | 7 |
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · 3 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 13 years and passes through 4 companies; a new generation was cleared every 9 months on median.
- 4 of the 18 ancestors have a recall of any class.
- Of its descendants, K042228 (Mckinley, Inc., 2004) has gone furthest, with 7 descendants of its own.
How does its category compare?
All FRN devicesFRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FRN
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRN
172in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRN
7in 2025
Class I (37 since 2007) Class II/III not classified
Adverse event reports per year · FRN
52,792in 2025
MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 102 | 15 | 1,086 |
| 2008 | 8 | 89 | 24 | 8,261 |
| 2009 | 9 | 66 | 102 | 1,952 |
| 2010 | 3 | 93 | 37 | 6,133 |
| 2011 | 3 | 103 | 69 | 41,367 |
| 2012 | 4 | 217 | 42 (2) | 15,482 |
| 2013 | 6 | 312 | 22 (3) | 40,082 |
| 2014 | 6 | 172 | 4 (3) | 94,180 |
| 2015 | 3 | 232 | 5 | 26,742 |
| 2016 | 3 | 301 | 7 (1) | 16,560 |
| 2017 | 3 | 305 | 13 | 12,060 |
| 2018 | 3 | 267 | 1 | 16,591 |
| 2019 | 2 | — | 18 (1) | 15,850 |
| 2020 | 1 | — | 16 (5) | 94,186 |
| 2021 | 2 | — | 3 (2) | 199,342 |
| 2022 | 6 | 268 | 2 | 888,020 |
| 2023 | 7 | 265 | 16 (10) | 165,838 |
| 2024 | 5 | 103 | 9 (4) | 57,730 |
| 2025 | 8 | 172 | 7 (4) | 52,792 |
| 2026 | 2 | — | 11 (2) | — |
What is it indicated for?
The Beeline system is indicated for intravenous, intra-arterial, enteral, subcutaneous and epidural infusion of medications or fluids requiring continuous delivery at controlled infusion rates.
The Beeline system is also intended to provide continuous infusion of a local anesthetic directly into the intraoperative site for postoperative pain management.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K032642 · printed Nov 6, 2026
Cite this page
510(k) Report. “K032642: Beeline System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032642
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026