510(k) Report

510(k) · Cleared

Recalled · 2011

VHP 136 Low Temperature Sterilization System

K062297510(k) TraditionalCleared Oct 4, 2007423-day reviewClass II21 CFR 880.6860Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

STERIS Corporation · MLR Sterilizer, Chemical

Cleared on Oct 4, 2007 after a 423-day review. The FDA summary names its predicate without a number. 31 later devices descend from it. It has been recalled once.

Decided
Oct 4, 2007
Review
423 days
Class
Class II
Product code
MLR
Recalls
1
Predicates
0

31 later devices descend from it, 8 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2011: 5 descendants cleared2013: 1 descendant cleared2024: 1 descendant cleared2012: 1 descendant cleared2014: 3 descendants cleared2016: 3 descendants cleared2021: 1 descendant cleared2019: 5 descendants cleared2018: 4 descendants cleared2017: 1 descendant cleared2023: 3 descendants cleared2022: 2 descendants cleared20052010201520202025
  1. This deviceK062297 VHP 136 Low Temperature Sterilization SystemSTERIS Corporation · 2007
  2. Descendant · cites it directly · 27 of its ownK083097 Amsco V-Pro 1 Low Temperature Sterilization SystemSTERIS Corporation · 2009 · Recalled
  3. Descendant · cites it directly · 21 of its ownK102330 Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011
  4. Descendant · 2 generations on · 18 of its ownK112760 Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011
  5. Descendant · cites it directly · 18 of its ownK111810 Amsco V-Pro 1 and V-Pro 1 Plus Low Temperature Sterilization UnitsSTERIS Corporation · 2011
  6. Descendant · cites it directly · 18 of its ownK102394 Amsco V-Pro 1 Low Temperature Sterilization System; Amsco V-Pro 1…STERIS Corporation · 2011

Showing 5 of 31 descendants. See all descendants

Descendants cleared per year

2009: 12011: 52012: 12013: 12014: 32016: 32017: 12018: 42019: 52021: 12022: 22023: 32024: 1
2009high 5 (2011) · low 0 (2010)2026

Most influential descendants

Showing 5 of 31 · See all
  • K083097Amsco V-Pro 1 Low Temperature Sterilization SystemSTERIS Corporation · 2009 · cites it directly27descendants
  • K102330Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011 · cites it directly21descendants
  • K112760Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011 · 2 generations on18descendants
  • K111810Amsco V-Pro 1 and V-Pro 1 Plus Low Temperature Sterilization UnitsSTERIS Corporation · 2011 · cites it directly18descendants
  • K102394Amsco V-Pro 1 Low Temperature Sterilization System; Amsco V-Pro 1 Plus Low Temperature…STERIS Corporation · 2011 · cites it directly18descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K062297VHP 136 Low Temperature Sterilization SystemSTERIS Corporation2007—
+1K083097Amsco V-Pro 1 Low Temperature Sterilization SystemSTERIS Corporation20091
+1K102330Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation2011—
+2K112760Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation2011—
+1K111810Amsco V-Pro 1 and V-Pro 1 Plus Low Temperature Sterilization UnitsSTERIS Corporation2011—
+1K102394Amsco V-Pro 1 Low Temperature Sterilization System; Amsco V-Pro 1 Plus Low…STERIS Corporation2011—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201150
201210
201310
201430
201630
201710
201840
201950
202110
202220
202330
202410
FIG. 1 — Lineage of K062297, 2007–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MLR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MLR device

  1. #1 K250802 STERRAD® 100NX Sterilizer with ALLClear™…score 14.0 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Sterrad 100S Sterilization System
Named without a submission number
—

What descends from it? (31)

See all 31

8 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K083097Amsco V-Pro 1 Low Temperature Sterilization SystemSTERIS Corporation200927
K102330Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation201121
K111810Amsco V-Pro 1 and V-Pro 1 Plus Low Temperature Sterilization UnitsSTERIS Corporation201118
K102394Amsco V-Pro 1 Low Temperature Sterilization System; Amsco V-Pro 1 Plus Low Temperature…STERIS Corporation201118
K120632Amsco V-Pro 1 Low/Plus/Max Temperature Sterilization SystemSTERIS Corporation201217
K131120Amsco V-Pro 1 Low, V-Pro 1 Plus, V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation201316
K231893LOWTEM Crystal 120Lowtem Co., Ltd.20240
K112813Amsco V-ProSteris Corp20110

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 1, 2011Not classifiedZ-3041-2011OtherSTERIS learned that Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems users may experience premature wear of the vacuum pump and filtering assembly components. Users may also experience incomplete aeration of the…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K083097 (STERIS Corporation, 2009) has gone furthest, with 27 descendants of its own.

How does its category compare?

All MLR devices

MLR Sterilizer, Chemical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · MLR

1in 2025

2007: 22009: 12011: 62012: 22013: 12014: 22015: 12016: 42017: 22018: 22019: 42021: 22022: 22023: 52024: 32025: 12026 (partial year): 1
2007high 6 (2011) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MLR

216in 2024

2011: 214 days median2016: 183 days median2019: 90 days median2023: 222 days median2024: 216 days median
2007high 222 (2023) · low 90 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MLR

1in 2017

2007: 52008: 82009: 22010: 12011: 22012: 32013: 92014: 32017: 1
2007high 9 (2013) · low 0 (2015)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MLR

46in 2025

2007: 2722008: 5362009: 4332010: 2112011: 342012: 1012013: 5412014: 3992015: 4122016: 2862017: 2792018: 2892019: 2222020: 1742021: 2022022: 1882023: 1402024: 442025: 46
2007high 541 (2013) · low 34 (2011)2025

MAUDE reports naming product code MLR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—5272
20080—8536
20091—2433
20100—1211
20116214234
20122—3101
20131—9541
20142—3399
20151—0412
201641830286
20172—1279
20182—0289
20194900222
20200—0174
20212—0202
20222—0188
202352220140
20243216044
20251—046
20261—0—

What is it indicated for?

The V-PRO 1 Low Temperature Sterilization System and Vaprox® HC Hydrogen Peroxide Sterilant (59%) are intended for use in terminal sterilization of cleaned, rinsed, and dried, reusable metal and nonmetal medical devices used in healthcare facilities. The V-PRO 1 Low Temperature Sterilization System can sterilize*: · Instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors. * Medical devices with a single stainless…

Read the full statement (177 words)

The V-PRO 1 Low Temperature Sterilization System and Vaprox® HC Hydrogen Peroxide Sterilant (59%) are intended for use in terminal sterilization of cleaned, rinsed, and dried, reusable metal and nonmetal medical devices used in healthcare facilities.

The V-PRO 1 Low Temperature Sterilization System can sterilize*:

· Instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors.

* Medical devices with a single stainless steel lumen with:

o an inside diameter of 1 mm or larger and a length of 125 mm or shorter

o an inside diameter of 2 mm or larger and a length of 250 mm or shorter

o an inside diameter of 3 mm or larger and a length of 400 mm or shorter

* The validation testing for all lumen sizes was conducted using a maximum of twenty (20) lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062297: VHP 136 Low Temperature Sterilization System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K062297

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026