510(k) Report

510(k) · Cleared

Cleared

Tenzing System

K102130510(k) SpecialCleared Aug 26, 201028-day reviewClass II21 CFR 882.4560

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mazor Surgical Technologies, Ltd. · HAW Neurological Stereotaxic Instrument

Cleared on Aug 26, 2010 as substantially equivalent to K073467 (Mazor Surgical Technologies, Ltd., 2008) and 1 other predicate after a 28-day review. Its family tree reaches back 8 generations to 1994. 1 of the 63 devices in its family, counting itself, has a Class I recall. 31 later devices descend from it.

Decided
Aug 26, 2010
Review
28 days
Class
Class II
Product code
HAW
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K911783 (1994). 31 ancestors in all, the oldest K811452 (1981). 31 later devices descend from it, 2 citing it directly. 1 of the 63 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2008: 1 other ancestor2006: 1 other ancestor2005: 2 other ancestors2004: 1 other ancestor2003: 2 other ancestors2000: 2 other ancestors1996: 1 other ancestor2002: 1 other ancestor2001: 4 other ancestors, 1 with a Class I recall11999: 1 other ancestor1997: 2 other ancestors1987: 1 other ancestor1981: 1 other ancestor1995: 3 other ancestors2011: 3 descendants cleared2018: 5 descendants cleared2012: 1 descendant cleared2014: 1 descendant cleared2015: 1 descendant cleared2023: 4 descendants cleared2017: 2 descendants cleared2020: 3 descendants cleared2021: 1 descendant cleared2024: 1 descendant cleared2026: 6 descendants cleared2025: 3 descendants clearedK911783 · Allegro Viewing Wand · I.S.G. Technologies, Inc. · 1994K960714 · Isg Viewing Wand · I.S.G. Technologies, Inc. · 1996K964229 · Regulus Navigator · Compass Intl., Inc. · 1997K981315 · Navitrack · Orthosoft, Inc. · 1998K033413 · Spineassist Device · Mazor Surgical Technologies, Ltd. · 2004K051676 · Spineassist Device with Additional Accessories · Mazor Surgical Technologies, Ltd. · 2005K063607 · Spineassist System · Mazor Surgical Technologies, Ltd. · 2007K073467 · Spineassist System · Mazor Surgical Technologies, Ltd. · 200819801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 7 other ancestors3 generations back: 7 other ancestors, 1 with a Class I recall14 generations back: 5 other ancestors5 generations back: 1 other ancestor6 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 4 descendants3 generations forward: 4 descendants4 generations forward: 2 descendants5 generations forward: 2 descendants6 generations forward: 1 descendant7 generations forward: 1 descendant8 generations forward: 1 descendant9 generations forward: 2 descendants10 generations forward: 5 descendants11 generations forward: 5 descendants12 generations forward: 2 descendants K073467 · Spineassist System · Mazor Surgical Technologies, Ltd. · 2008K063607 · Spineassist System · Mazor Surgical Technologies, Ltd. · 2007K051676 · Spineassist Device with Additional Accessories · Mazor Surgical Technologies, Ltd. · 2005K033413 · Spineassist Device · Mazor Surgical Technologies, Ltd. · 2004K981315 · Navitrack · Orthosoft, Inc. · 1998K964229 · Regulus Navigator · Compass Intl., Inc. · 1997K960714 · Isg Viewing Wand · I.S.G. Technologies, Inc. · 1996K911783 · Allegro Viewing Wand · I.S.G. Technologies, Inc. · 1994−50+5+10
  1. Root · 8 generations backK911783 Allegro Viewing WandI.S.G. Technologies, Inc. · 1994
  2. 7 generations backK960714 Isg Viewing WandI.S.G. Technologies, Inc. · 1996
  3. 6 generations backK964229 Regulus NavigatorCompass Intl., Inc. · 1997
  4. 5 generations backK981315 NavitrackOrthosoft, Inc. · 1998
  5. 4 generations backK033413 Spineassist DeviceMazor Surgical Technologies, Ltd. · 2004
  6. 3 generations backK051676 Spineassist Device with Additional AccessoriesMazor Surgical Technologies, Ltd. · 2005
  7. 2 generations backK063607 Spineassist SystemMazor Surgical Technologies, Ltd. · 2007
  8. 1 generation backK073467 Spineassist SystemMazor Surgical Technologies, Ltd. · 2008
  9. This deviceK102130 Tenzing SystemMazor Surgical Technologies, Ltd. · 2010
  10. Descendant · cites it directly · 24 of its ownK110911 Renaissance SystemMazor Robotics, Ltd. · 2011
  11. Descendant · 2 generations on · 23 of its ownK113228 Renaissance SystemMazor Robotics, Ltd. · 2011
  12. Descendant · 3 generations on · 21 of its ownK140167 Renaissance X SystemMazor Robotics, Ltd. · 2014
  13. Descendant · 2 generations on · 21 of its ownK120812 RenaissanceMazor Robotics, Ltd. · 2012 · Recalled
  14. Descendant · 3 generations on · 20 of its ownK152041 Renaissance X SystemMazor Robotics, Ltd. · 2015

Showing 5 of 31 descendants. See all descendants

Descendants cleared per year

2011: 32012: 12014: 12015: 12017: 22018: 52020: 32021: 12023: 42024: 12025: 32026: 6
2011high 6 (2026) · low 0 (2013)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 31 · See all
  • K110911Renaissance SystemMazor Robotics, Ltd. · 2011 · cites it directly24descendants
  • K113228Renaissance SystemMazor Robotics, Ltd. · 2011 · 2 generations on23descendants
  • K140167Renaissance X SystemMazor Robotics, Ltd. · 2014 · 3 generations on21descendants
  • K120812RenaissanceMazor Robotics, Ltd. · 2012 · 2 generations on21descendants
  • K152041Renaissance X SystemMazor Robotics, Ltd. · 2015 · 3 generations on20descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K911783Allegro Viewing WandI.S.G. Technologies, Inc.1994—
−7K960714Isg Viewing WandI.S.G. Technologies, Inc.1996—
−6K964229Regulus NavigatorCompass Intl., Inc.1997—
−5K981315NavitrackOrthosoft, Inc.1998—
−4K033413Spineassist DeviceMazor Surgical Technologies, Ltd.2004—
−3K051676Spineassist Device with Additional AccessoriesMazor Surgical Technologies, Ltd.2005—
−2K063607Spineassist SystemMazor Surgical Technologies, Ltd.2007—
−1K073467Spineassist SystemMazor Surgical Technologies, Ltd.2008—
0 (this device)K102130Tenzing SystemMazor Surgical Technologies, Ltd.2010—
+1K110911Renaissance SystemMazor Robotics, Ltd.2011—
+2K113228Renaissance SystemMazor Robotics, Ltd.2011—
+3K140167Renaissance X SystemMazor Robotics, Ltd.2014—
+2K120812RenaissanceMazor Robotics, Ltd.20121
+3K152041Renaissance X SystemMazor Robotics, Ltd.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198710
199530
199610
199720
199910
200020
200141
200210
200320
200410
200520
200610
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201130
201210
201410
201510
201720
201850
202030
202110
202340
202410
202530
202660
FIG. 1 — Lineage of K102130, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HAW device

  1. #1 K253856 Geniant Cranial (Navigated Neurosurgical…score 15.0 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K073467Spineassist System
Summary page 1
…and LLZ 4. Predicate Devices The TenZing System is substantially equivalent to the following devices Mazor Surgical Technologies SpineAssist K073467 05/23/2008 Mazor Surgical Technologies C-InSight K081672 08/15/2008…
Mazor Surgical Technologies, Ltd.2008—
*K081672C-Insight
Summary page 1
…lent to the following devices Mazor Surgical Technologies SpineAssist K073467 05/23/2008 Mazor Surgical Technologies C-InSight K081672 08/15/2008 469 5. Device Description The T…
Mazor Surgical Technologies, Ltd.2008—

What descends from it? (31)

See all 31

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110911Renaissance SystemMazor Robotics, Ltd.201124
K103400Fluoromap Software, 9 Fluorodisc (Belt), 12 Fluoro Disc (Belt), Close Tube ClipStryker Corporation20115

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K003837Flexiview 8800 Digital Mobile Imaging SystemGe Oec Medical Systems · 2001 · 3 generations back · ◆ in the 2001 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 2.0 years on median.
  • 7 of the 31 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K110911 (Mazor Robotics, Ltd., 2011) has gone furthest, with 24 descendants of its own.

How does its category compare?

All HAW devices

HAW Neurological Stereotaxic Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · HAW

9in 2025

2007: 152008: 122009: 82010: 62011: 42012: 82013: 32014: 52015: 102016: 92017: 72018: 62019: 102020: 52021: 92022: 72023: 142024: 72025: 92026 (partial year): 5
2007high 15 (2007) · low 3 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HAW

163in 2025

2007: 107 days median2008: 112 days median2009: 221 days median2010: 138 days median2011: 66 days median2012: 178 days median2013: 172 days median2014: 238 days median2015: 232 days median2016: 175 days median2017: 226 days median2018: 112 days median2019: 147 days median2020: 88 days median2021: 168 days median2022: 128 days median2023: 142 days median2024: 107 days median2025: 163 days median2026 (partial year): 162 days median
2007high 238 (2014) · low 66 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HAW

2in 2025

2007: 22008: 102009: 62010: 282011: 52012: 42013: 6, 1 Class I2014: 52015: 32016: 52017: 22018: 2, 2 Class I2019: 4, 1 Class I2020: 12021: 4, 2 Class I2022: 12023: 4, 1 Class I2024: 2, 2 Class I2025: 22026 (partial year): 6
2007high 28 (2010) · low 1 (2020)2026

Class I (9 since 2007) Class II/III not classified

Adverse event reports per year · HAW

3,425in 2025

2007: 492008: 532009: 962010: 2992011: 1,7252012: 9862013: 1,2902014: 1,6062015: 1,7672016: 1,8282017: 3,5052018: 4,4392019: 6,0622020: 3,4802021: 2,8272022: 1,9292023: 2,5102024: 3,7552025: 3,425
2007high 6,062 (2019) · low 49 (2007)2025

MAUDE reports naming product code HAW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715107249
2008121121053
20098221696
2010613828299
201146651,725
201281784986
201331726 (1)1,290
2014523851,606
20151023231,767
2016917551,828
2017722623,505
201861122 (2)4,439
2019101474 (1)6,062
202058813,480
202191684 (2)2,827
2022712811,929
2023141424 (1)2,510
202471072 (2)3,755
2025916323,425
202651626—

What is it indicated for?

The TenZing System is a combination of the SpineAssist System and C-InSight System, allowing the C-InSight application to run on the SpineAssist Workstation:

The SpineAssistTM System is indicated for precise positioning of surgical instruments or implants during general spinal surgery. The SpineAssistTM System may be used in either open or percutaneous procedures.

The C-InSight software provides a processing and conversion of 2D fluoroscopic projections from standard C-Arms into volumetric 3D image.

It is intended to be used whenever the clinician and/or patient benefits from generated 3D imaging of high contrast objects, particularly for orthopedic applications.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K102130: Tenzing System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K102130

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026