510(k) · Cleared
ClearedP-140-Flex Coil, Na-140-Flex Coil, C-140-Flex Coil
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Rapid Biomedical GmbH · MOS Coil, Magnetic Resonance, Specialty
Cleared on Mar 21, 2018 as substantially equivalent to K043147 (Philips Medical Systems North America Co., 2005) after a 449-day review. Its family tree reaches back 2 generations to 2003. 1 of the 3 devices in its family, counting itself, has a Class I recall.
- Decided
- Mar 21, 2018
- Review
- 449 days
- Class
- Class II
- Product code
- MOS
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K031815 (2003). No later device cites it as a predicate yet. 1 of the 3 devices in this family, counting this one, has a Class I recall.
- Root · 2 generations backK031815 Intera-Sensation FamilyPhilips Medical Systems · 2003 · Recalled
- 1 generation backK043147 Achieva FamilyPhilips Medical Systems North America Co. · 2005 · Recalled (Class I)
- This deviceK163661 P-140-Flex Coil, Na-140-Flex Coil, C-140-Flex CoilRapid Biomedical GmbH · 2018
Class I recalls in this family
- K043147 Achieva Familydirect predicate · 2005
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MOS device
- #1 K253738 3.0T Air 32CH Hnascore 15.2 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K043147 | Achieva FamilySummary page 5…n of the cleared Philips Magnetic Resonance Diagnostic Devices (MRDD) which are described in the submission: Predicate Device Name Clearance Number Date ACHIEVA family K043147 2005-02-15 File: 001_K163661_Suppl001_510(k) Summary.doc Confidential _ Page 2/4 RAPID Traditional 510(k) Premar… | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K043147Achieva FamilyPhilips Medical Systems North America Co. · 2005 · Direct predicate · ◆ on the line of descent in FIG. 13 Class I recalls
What does this lineage say?
- The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 13.1 years on median.
- 2 of the 2 ancestors have a recall of any class; 1 has a Class I recall.
- 5 other devices also cite its predicate K043147.
How does its category compare?
All MOS devicesMOS Coil, Magnetic Resonance, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · MOS
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MOS
59in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MOS
13in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MOS
2in 2025
MAUDE reports naming product code MOS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 19 | 0 | 4 |
| 2008 | 19 | 33 | 2 | 2 |
| 2009 | 10 | 43 | 0 | 5 |
| 2010 | 16 | 78 | 1 | 13 |
| 2011 | 25 | 57 | 0 | 7 |
| 2012 | 15 | 49 | 1 | 12 |
| 2013 | 7 | 87 | 0 | 10 |
| 2014 | 12 | 60 | 0 | 4 |
| 2015 | 6 | 58 | 2 | 5 |
| 2016 | 11 | 42 | 0 | 7 |
| 2017 | 9 | 63 | 0 | 9 |
| 2018 | 10 | 30 | 0 | 7 |
| 2019 | 3 | 178 | 8 | 8 |
| 2020 | 5 | 51 | 1 | 2 |
| 2021 | 4 | 41 | 0 | 3 |
| 2022 | 11 | 79 | 0 | 5 |
| 2023 | 10 | 59 | 0 | 4 |
| 2024 | 10 | 39 | 13 | 8 |
| 2025 | 3 | 59 | 0 | 2 |
| 2026 | 10 | 45 | 0 | — |
What is it indicated for?
The P-140-Flex Coil, Na-140-Flex Coil and C-140-Flex Coil are indicated for use as diagnostic device extensions for Philips 3.0 T MR Systems to produce cross-sectional spectroscopy images and/or spectra in any orientation of the internal structure of the whole body, e.g. of the calf, liver or heart. These images when interpreted by a trained physician, yield information that may assist in diagnosis.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K163661 · printed Nov 6, 2026
Cite this page
510(k) Report. “K163661: P-140-Flex Coil, Na-140-Flex Coil, C-140-Flex Coil.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K163661
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026