510(k) Report

510(k) · Cleared

Recalled · Class I · 2026

Achieva, Intera and Panorama 1.0T, Release 2.5

K063559510(k) TraditionalCleared Jan 4, 200738-day reviewClass II21 CFR 892.1000Recalls 10 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems · LNH System, Nuclear Magnetic Resonance Imaging

Cleared on Jan 4, 2007 as substantially equivalent to K043147 (Philips Medical Systems North America Co., 2005) and 3 other predicates after a 38-day review. Its family tree reaches back 3 generations to 2003. 4 of the 60 devices in its family, counting itself, have a Class I recall. 53 later devices descend from it. It has been recalled 10 times, including a Class I recall.

Decided
Jan 4, 2007
Review
38 days
Class
Class II
Product code
LNH
Recalls
10 (1 Class I)
Predicates
4

Its longest line of descent runs back 3 generations to K031815 (2003). 6 ancestors in all, the oldest K001796 (2000). 53 later devices descend from it, 7 citing it directly. 4 of the 60 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor, 1 with a Class I recall12001: 1 other ancestor2000: 1 other ancestor2019: 2 descendants cleared2017: 3 descendants cleared2010: 2 descendants cleared2011: 3 descendants cleared2018: 9 descendants cleared2015: 4 descendants cleared2016: 3 descendants cleared2013: 1 descendant cleared2012: 1 descendant cleared2020: 3 descendants cleared2026: 2 descendants cleared2021: 4 descendants cleared2022: 8 descendants cleared2025: 3 descendants cleared2023: 5 descendants clearedK031815 · Intera-Sensation Family · Philips Medical Systems · 2003 · recalledK041602 · Panorama 1.0T · Philips Medical Systems North America, Inc. · 2004 · Class I recallK052078 · Achieva, Intera and Panorama 1.0 Release 2-Series · Philips Medical Systems Nederland B.V. · 2005 · Class I recall200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors, 1 with a Class I recall12 generations back: 1 other ancestor 1 generation forward: 7 descendants2 generations forward: 11 descendants3 generations forward: 9 descendants4 generations forward: 11 descendants5 generations forward: 5 descendants6 generations forward: 2 descendants7 generations forward: 3 descendants8 generations forward: 3 descendants9 generations forward: 2 descendants K052078 · Achieva, Intera and Panorama 1.0 Release 2-Series · Philips Medical Systems Nederland B.V. · 2005 · Class I recallK041602 · Panorama 1.0T · Philips Medical Systems North America, Inc. · 2004 · Class I recallK031815 · Intera-Sensation Family · Philips Medical Systems · 2003 · recalled0+5
  1. Root · 3 generations backK031815 Intera-Sensation FamilyPhilips Medical Systems · 2003 · Recalled
  2. 2 generations backK041602 Panorama 1.0TPhilips Medical Systems North America, Inc. · 2004 · Recalled (Class I)
  3. 1 generation backK052078 Achieva, Intera and Panorama 1.0 Release 2-SeriesPhilips Medical Systems Nederland B.V. · 2005 · Recalled (Class I)
  4. This deviceK063559 Achieva, Intera and Panorama 1.0T, Release 2.5Philips Medical Systems · 2007
  5. Descendant · cites it directly · 34 of its ownK110151 Achieva R4 1.5T and Achieva R4 3.0TPhilips Health Care · 2011 · Recalled
  6. Descendant · 2 generations on · 19 of its ownK163116 Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3Philips Medical Systems Nederland B.V. · 2017 · Recalled
  7. Descendant · 3 generations on · 15 of its ownK173079 Ingenia 1.5T, Ingenia 1 5T S, Ingenia 1.5T CX, Ingenia 3.0T CX R5.4Philips Medical Systems Nederland B.V. · 2018 · Recalled
  8. Descendant · 4 generations on · 13 of its ownK183063 Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR SystemsPhilips Medical Systems Nederland B.V. · 2019 · Recalled
  9. Descendant · 2 generations on · 13 of its ownK143606 MultiBand SENSEPhilips Medical Systems Nethrlands BV · 2015

Showing 5 of 53 descendants. See all descendants

Descendants cleared per year

2010: 22011: 32012: 12013: 12015: 42016: 32017: 32018: 92019: 22020: 32021: 42022: 82023: 52025: 32026: 2
2010high 9 (2018) · low 0 (2014)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 53 · See all
  • K110151Achieva R4 1.5T and Achieva R4 3.0TPhilips Health Care · 2011 · cites it directly34descendants
  • K163116Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3Philips Medical Systems Nederland B.V. · 2017 · 2 generations on19descendants
  • K173079Ingenia 1.5T, Ingenia 1 5T S, Ingenia 1.5T CX, Ingenia 3.0T CX R5.4Philips Medical Systems Nederland B.V. · 2018 · 3 generations on15descendants
  • K183063Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR SystemsPhilips Medical Systems Nederland B.V. · 2019 · 4 generations on13descendants
  • K143606MultiBand SENSEPhilips Medical Systems Nethrlands BV · 2015 · 2 generations on13descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K031815Intera-Sensation FamilyPhilips Medical Systems20033
−2K041602Panorama 1.0TPhilips Medical Systems North America, Inc.2004Class I
−1K052078Achieva, Intera and Panorama 1.0 Release 2-SeriesPhilips Medical Systems Nederland B.V.2005Class I
0 (this device)K063559Achieva, Intera and Panorama 1.0T, Release 2.5Philips Medical Systems2007—
+1K110151Achieva R4 1.5T and Achieva R4 3.0TPhilips Health Care201120
+2K163116Ingenia 1.5T, Ingenia 1.5T S and Ingenia 3.0T R5.3Philips Medical Systems Nederland B.V.20177
+3K173079Ingenia 1.5T, Ingenia 1 5T S, Ingenia 1.5T CX, Ingenia 3.0T CX R5.4Philips Medical Systems Nederland B.V.201811
+4K183063Ingenia, Ingenia CX, Ingenia Elition, and Ingenia Ambition MR SystemsPhilips Medical Systems Nederland B.V.201925
+2K143606MultiBand SENSEPhilips Medical Systems Nethrlands BV2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
200110
200511

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201020
201130
201210
201310
201540
201630
201730
201890
201920
202030
202140
202280
202350
202530
202620
FIG. 1 — Lineage of K063559, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

4 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LNH device

  1. #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K043147Achieva Family
Summary page 1
…, INTERA and PANORAMA 1.0T Release 2.5-series are the successor of the predicate devices ACHIEVA, INTERA and PANORAMA LOT release 2-series. (FDA references K043147, K041602, K052078 and KO 13344). Indications for use: The ACHIEVA, INTERA and PANORAMA 1.0T Release 2.5-series are…
Philips Medical Systems North America Co.2005Class I
*K041602Panorama 1.0T
Summary page 1
…and PANORAMA 1.0T Release 2.5-series are the successor of the predicate devices ACHIEVA, INTERA and PANORAMA LOT release 2-series. (FDA references K043147, K041602, K052078 and KO 13344). Indications for use: The ACHIEVA, INTERA and PANORAMA 1.0T Release 2.5-series are…
Philips Medical Systems North America, Inc.2004Class I
*K052078Achieva, Intera and Panorama 1.0 Release 2-Series
Summary page 1
…AMA 1.0T Release 2.5-series are the successor of the predicate devices ACHIEVA, INTERA and PANORAMA LOT release 2-series. (FDA references K043147, K041602, K052078 and KO 13344). Indications for use: The ACHIEVA, INTERA and PANORAMA 1.0T Release 2.5-series are magnetic…
Philips Medical Systems Nederland B.V.2005Class I
*K013344Intera I/TPhilips Medical Systems North America Co.20012

Also cleared against K043147: 5 other devices →

What descends from it? (53)

See all 53

7 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110151Achieva R4 1.5T and Achieva R4 3.0TPhilips Health Care201134
K100836Clearpoint SystemSurgivision, Inc.201012
K181892Ziostation2Ziosoft, Inc.20181
K162931Ingenia 1.5T CX and Ingenia 3.0T CX R5.3Philips Medical Systems Nederland B.V.20171
K102344Mdixon Software Option for Intera 1.5T, Achieva 1.5T & Achieva 3.0T MR SystemsPhilips Medical Systems Nederland B.V.20101
K190461Achieva 1.5T, 3.0T and Intera 1.5T MR SystemsPhilips Medical Systems Nederland B.V.20190
K103483Ingenuity TF Pet/MRPhilips Healthcare (Cleveland)20110

Has anything in its family been recalled? (4 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 21, 2026Class IIZ-3232-2026Software designA software issue will terminate an examination during the image reconstruction process if the scan parameters are manually adjusted such that reconstruction requirements exceed the available system memory.
May 3, 2024Class IIZ-1855-2024Under Investigation by firmThe g-MDU (global Mains Distribution Unit) L3 terminal connection may become loose creating a hotspot that may cause smoke/fire to alarm in the hospital's technical room, resulting in Smoke and/or fire
Nov 17, 2023Class IZ-0505-2024Component design/selectionFirm was informed of an event in which the structural integrity of the MR system components failed due to unintended excessive pressure buildup of helium gas during a magnet quench. If the system is unable to contain the pressured helium…
Oct 23, 2023Class IIZ-0393-2024Under Investigation by firmPotential component failure in the Gradient Coil could product smoke and/or fire.
Oct 23, 2023Class IIZ-0389-2024Under Investigation by firmPotential component failure in the Gradient Coil could product smoke and/or fire.
Oct 23, 2023Class IIZ-0390-2024Under Investigation by firmPotential component failure in the Gradient Coil could product smoke and/or fire.
Oct 23, 2023Class IIZ-0392-2024Under Investigation by firmPotential component failure in the Gradient Coil could product smoke and/or fire.
Aug 21, 2014Class IIZ-0325-2016Software Design ChangeWhen a fused series of a sagittal, coronal or radial multi station scan is generated in MobiView, the resultant image order is reversed. This occurs with software release R5.1.7/R5.1.8.
May 5, 2014Class IIZ-0135-2016Software designIn spine clinical workflows, cross reference lines may be used to determine the position of slices. In cases, where MobiView fused Images are used to show the cross reference lines, the cross reference lines may be positioned incorrectly.
Aug 13, 2008Not classifiedZ-0971-2009Process designBattery Failure: The Invivo Lithium Polymer Wireless Module Battery Part Number 9065 and the Lithium Polymer Fiber Optic Module Battery Part Number 9067 is being recalled because the battery, itself, when dropped from 3 feet/1 meter onto…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K052078Achieva, Intera and Panorama 1.0 Release 2-SeriesPhilips Medical Systems Nederland B.V. · 2005 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall
  • K043147Achieva FamilyPhilips Medical Systems North America Co. · 2005 · Direct predicate · ◆ in the 2005 ancestors bar of FIG. 13 Class I recalls
  • K041602Panorama 1.0TPhilips Medical Systems North America, Inc. · 2004 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 4 years and passes through 3 companies; a new generation was cleared every 1.1 years on median.
  • 6 of the 6 ancestors have a recall of any class; 3 have a Class I recall.
  • Of its descendants, K110151 (Philips Health Care, 2011) has gone furthest, with 34 descendants of its own.
  • 5 other devices also cite its predicate K043147.

How does its category compare?

All LNH devices

LNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · LNH

26in 2025

2007: 122008: 192009: 172010: 122011: 162012: 222013: 192014: 172015: 192016: 202017: 182018: 292019: 262020: 322021: 272022: 302023: 302024: 262025: 262026 (partial year): 24
2007high 32 (2020) · low 12 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LNH

122in 2025

2007: 35 days median2008: 53 days median2009: 70 days median2010: 94 days median2011: 81 days median2012: 89 days median2013: 108 days median2014: 108 days median2015: 140 days median2016: 108 days median2017: 98 days median2018: 128 days median2019: 62 days median2020: 121 days median2021: 87 days median2022: 74 days median2023: 124 days median2024: 104 days median2025: 122 days median2026 (partial year): 126 days median
2007high 140 (2015) · low 35 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LNH

8in 2025

2007: 252008: 122009: 72010: 172011: 112012: 52013: 22014: 132015: 12, 2 Class I2016: 12018: 712019: 52020: 42021: 412022: 132023: 10, 1 Class I2024: 42025: 8, 5 Class I2026 (partial year): 43
2007high 71 (2018) · low 0 (2017)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · LNH

1,263in 2025

2007: 1142008: 1672009: 1942010: 1652011: 1822012: 1702013: 1072014: 1192015: 1132016: 1352017: 1212018: 1582019: 1582020: 982021: 842022: 1382023: 1592024: 2812025: 1,263
2007high 1,263 (2025) · low 84 (2021)2025

MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123525114
2008195312167
200917707194
2010129417165
2011168111182
201222895170
2013191082107
20141710813119
20151914012 (2)113
2016201081135
201718980121
20182912871158
201926625158
202032121498
202127874184
2022307413138
20233012410 (1)159
2024261044281
2025261228 (5)1,263
20262412643—

What is it indicated for?

The ACIREVA, INTERA and PANORAMA LOT Release 2.5-series are magnetic resonance diagnostic devices that produce cross-sectional images, spectroscopy images and/or spectra in any orientation of the internal structure of the whole body. These images when interpreted by a trained physician, yield information that may assist in diagnosis.

In addition the Achieva, Intera and Panorama 1.OT devices provide capabilities to perform interventional procedures in the head, body and extremities, which may be facilitated by MR techniques, such as real time imaging. Such procedures must be performed with MR compatible instrumentation as selected and evaluated by the clinical user.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K063559: Achieva, Intera and Panorama 1.0T, Release 2.5.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K063559

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026