HemoCare Hemodialysis System

K233557510(k) TraditionalCleared Jul 12, 2024249-day reviewClass II21 CFR 876.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Deka Research and Development · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Jul 12, 2024 as substantially equivalent to K010131 (Aksys, Ltd., 2002) and 3 other predicates after a 249-day review. Its family tree reaches back 12 generations to 1994.

Decided
Jul 12, 2024
Review
249 days
Class
Class II
Product code
KDI
Recalls
None
Predicates
4

Its longest line of descent runs back 12 generations to K921456 (1994). 44 ancestors in all, the oldest K770691 (1977). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2022: 1 other ancestor2014: 2 other ancestors2002: 1 other ancestor2012: 1 other ancestor1997: 2 other ancestors1994: 1 other ancestor1990: 1 other ancestor1989: 2 other ancestors1988: 2 other ancestors1987: 1 other ancestor1984: 1 other ancestor1981: 1 other ancestor1977: 1 other ancestor2013: 1 other ancestor2009: 1 other ancestor2007: 1 other ancestor2005: 1 other ancestor2004: 1 other ancestor2001: 2 other ancestors1999: 2 other ancestors1998: 1 other ancestor1995: 1 other ancestor2010: 1 other ancestor2000: 1 other ancestor2003: 1 other ancestor1996: 1 other ancestorK921456 · Fresenius 3008/FDS-08 Dialysate Delivery System · Fresenius USA, Inc. · 1994 · recalledK994267 · Fresenius 2008K · Fresenius Medical Care · 2000 · recalledK080964 · Fresenius Model 2008T Hemodialysis Machine · Fresenius Medical Care North America · 2009 · recalledK093902 · Modification to:Fresenius 2008T Hemodialysis Machine, Model 190573 · Fresenius Medical Care North America · 2010 · recalled×3: 3 generations cleared close together, K111639 (2011), K113427 (2011), K120505 (2012) K140866 · Tablo Console · Home Dialysis Plus · 2014K150880 · Tablo Console with Wireless Capability · Outset Medical · 2015K160881 · Tablo Console · Outset Medical, Inc. · 2016K200741 · Tablo Hemodialysis System · Outset Medical, Inc. · 2020 · recalledK211370 · Tablo Hemodialysis System · Outset Medical, Inc. · 2022 · recalled19801990200020102020
  1. Root · 12 generations backK921456 Fresenius 3008/FDS-08 Dialysate Delivery SystemFresenius USA, Inc. · 1994 · Recalled
  2. 8 generations between
  3. 3 generations backK160881 Tablo ConsoleOutset Medical, Inc. · 2016
  4. 2 generations backK200741 Tablo Hemodialysis SystemOutset Medical, Inc. · 2020 · Recalled
  5. 1 generation backK211370 Tablo Hemodialysis SystemOutset Medical, Inc. · 2022 · Recalled
  6. This deviceK233557 HemoCare Hemodialysis SystemDeka Research and Development · 2024
Show all 12 generations
  1. Root · 12 generations backK921456 Fresenius 3008/FDS-08 Dialysate Delivery SystemFresenius USA, Inc. · 1994 · Recalled
  2. 11 generations backK994267 Fresenius 2008KFresenius Medical Care · 2000 · Recalled
  3. 10 generations backK080964 Fresenius Model 2008T Hemodialysis MachineFresenius Medical Care North America · 2009 · Recalled
  4. 9 generations backK093902 Modification to:Fresenius 2008T Hemodialysis Machine, Model 190573Fresenius Medical Care North America · 2010 · Recalled
  5. 8 generations backK111639 Fresenius 2008T Hemodialysis MachineFresenius Medical Care · 2011 · Recalled
  6. 7 generations backK113427 Fresenius 2008T Hemodialysis MachineFresenius Medical Care North America · 2011 · Recalled
  7. 6 generations backK120505 Fresenius 2008T Hemodialysis MachineFresenius Medical Care North America, Design Cente · 2012 · Recalled
  8. 5 generations backK140866 Tablo ConsoleHome Dialysis Plus · 2014
  9. 4 generations backK150880 Tablo Console with Wireless CapabilityOutset Medical · 2015
  10. 3 generations backK160881 Tablo ConsoleOutset Medical, Inc. · 2016
  11. 2 generations backK200741 Tablo Hemodialysis SystemOutset Medical, Inc. · 2020 · Recalled
  12. 1 generation backK211370 Tablo Hemodialysis SystemOutset Medical, Inc. · 2022 · Recalled
  13. This deviceK233557 HemoCare Hemodialysis SystemDeka Research and Development · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K921456Fresenius 3008/FDS-08 Dialysate Delivery SystemFresenius USA, Inc.19943
−11K994267Fresenius 2008KFresenius Medical Care20005
−10K080964Fresenius Model 2008T Hemodialysis MachineFresenius Medical Care North America20094
−9K093902Modification to:Fresenius 2008T Hemodialysis Machine, Model 190573Fresenius Medical Care North America20102
−8K111639Fresenius 2008T Hemodialysis MachineFresenius Medical Care20111
−7K113427Fresenius 2008T Hemodialysis MachineFresenius Medical Care North America20114
−6K120505Fresenius 2008T Hemodialysis MachineFresenius Medical Care North America, Design Cente20124
−5K140866Tablo ConsoleHome Dialysis Plus2014—
−4K150880Tablo Console with Wireless CapabilityOutset Medical2015—
−3K160881Tablo ConsoleOutset Medical, Inc.2016—
−2K200741Tablo Hemodialysis SystemOutset Medical, Inc.20201
−1K211370Tablo Hemodialysis SystemOutset Medical, Inc.20221
0 (this device)K233557HemoCare Hemodialysis SystemDeka Research and Development2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197710
198110
198410
198710
198820
198920
199010
199410
199510
199610
199720
199810
199920
200010
200120
200210
200310
200410
200510
200710
200910
201010
201210
201310
201420
202210
FIG. 1 — Lineage of K233557, 1994–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K010131PHD Personal Hemodialysis Instrument-1M101, PHD Water Pre-Treatment Kit-1W605,PHD Hard…
Summary page 6
…Page 2 of 9 DEKA Research & Development Corp. 3 Predicate Device Predicate Device comparisons were made to the following four devices: • Aksys PHD (K010131, cleared on March 26, 2002) is indicated for the same therapy, the same user population and in the same use environments.…
Aksys, Ltd.20021
*K210575HDF Assist Mudule, HDF Infusion Set and Substitution Filter
Summary page 6
…s delivery, blood flow control, ultrafiltration, reusable blood treatment set, and automatic post-treatment device disinfection. • Nephros HDF Assist Module (K210575, cleared May 13, 2022) provides a predicate device that performs online generation of substitution fluid from commercially…
Nephros2022—
*K141752Nxstage System One
Summary page 6
…device that performs online generation of substitution fluid from commercially available (510(k) cleared) chemical concentrates. • NxStage System One (K141752, cleared 12/19/2014) provides a predicate device that has the same home, nocturnal hemodialysis indication. • Outset…
Nxstage Medical, Inc.2014—
*K211370Tablo Hemodialysis System
Summary page 6
…• NxStage System One (K141752, cleared 12/19/2014) provides a predicate device that has the same home, nocturnal hemodialysis indication. • Outset Tablo (K211370, cleared July 29, 2022) provides a predicate device since it features integrated water purification, and two-way wireless…
Outset Medical, Inc.20221

Also cleared against K010131: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 8 companies; a new generation was cleared every 2.0 years on median.
  • 15 of the 44 ancestors have a recall of any class.
  • 4 other devices also cite its predicate K010131.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

The HemoCare® Hemodialysis System is indicated for hemodialysis treatment, including short daily and nocturnal hemodialysis, of renal failure patients. The HemoCare Hemodialysis System is indicated for use in chronic dialysis facilities, self-care dialysis facilities, and the home setting. All treatments must be prescribed by a physician and administered by a trained operator. Treatments must be performed with the assistance or observation of an individual who has been trained and is considered competent in the use of the device. The HemoCare Hemodialysis System is not indicated for solo hemodialysis in the home setting.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K233557: HemoCare Hemodialysis System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K233557

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026