510(k) Report

510(k) · Cleared

Recalled · Class II · 2025

Modified Volumetric Infusion Pump

K913661510(k) TraditionalCleared Dec 18, 1991138-day reviewClass II21 CFR 880.5725Recalls 19

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mcgaw, Inc. · FRN Pump, Infusion

Cleared on Dec 18, 1991 after a 138-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 6 of the 18 devices in its family, counting itself, have a Class I recall. 17 later devices descend from it. It has been recalled 19 times.

Decided
Dec 18, 1991
Review
138 days
Class
Class II
Product code
FRN
Recalls
19
Predicates
0

17 later devices descend from it, 1 citing it directly. 6 of the 18 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 1997: 1 descendant cleared2006: 1 descendant cleared, 1 with a Class I recall12014: 2 descendants cleared, 1 with a Class I recall12020: 3 descendants cleared, 1 with a Class I recall12013: 1 descendant cleared, 1 with a Class I recall12009: 1 descendant cleared, 1 with a Class I recall12015: 1 descendant cleared, 1 with a Class I recall12022: 3 descendants cleared2016: 1 descendant cleared2017: 1 descendant cleared2025: 1 descendant cleared2021: 1 descendant cleared1990200020102020
  1. This deviceK913661 Modified Volumetric Infusion PumpMcgaw, Inc. · 1991
  2. Descendant · cites it directly · 16 of its ownK972678 Millennium CRT Infusion Pump and Millennium CRT Infusion Pump…Mcgaw, Inc. · 1997
  3. Descendant · 2 generations on · 15 of its ownK062700 Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · Recalled (Class I)
  4. Descendant · 3 generations on · 6 of its ownK140838 IV Administration Set with Hand PumpB.Braun Medical, Inc. · 2014
  5. Descendant · 3 generations on · 4 of its ownK083689 Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · Recalled (Class I)
  6. Descendant · 4 generations on · 3 of its ownK170595 IV Administration SetsB.Braun Medical, Inc. · 2017 · Recalled

Showing 5 of 17 descendants. See all descendants

Descendants cleared per year

1997: 12006: 12009: 12013: 12014: 22015: 12016: 12017: 12020: 32021: 12022: 32025: 1
1997high 3 (2020) · low 0 (1998)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 17 · See all
  • K972678Millennium CRT Infusion Pump and Millennium CRT Infusion Pump Administration SetsMcgaw, Inc. · 1997 · cites it directly16descendants
  • K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · 2 generations on15descendants
  • K140838IV Administration Set with Hand PumpB.Braun Medical, Inc. · 2014 · 3 generations on6descendants
  • K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · 3 generations on4descendants
  • K170595IV Administration SetsB.Braun Medical, Inc. · 2017 · 4 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K913661Modified Volumetric Infusion PumpMcgaw, Inc.1991—
+1K972678Millennium CRT Infusion Pump and Millennium CRT Infusion Pump Administration…Mcgaw, Inc.1997—
+2K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc.2006Class I
+3K140838IV Administration Set with Hand PumpB.Braun Medical, Inc.2014—
+3K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc.2009Class I
+4K170595IV Administration SetsB.Braun Medical, Inc.201719

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199710
200611
200911
201311
201421
201511
201610
201710
202031
202110
202230
202510
FIG. 1 — Lineage of K913661, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

6 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.

What descends from it? (17)

See all 17

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K972678Millennium CRT Infusion Pump and Millennium CRT Infusion Pump Administration SetsMcgaw, Inc.199716

Has anything in its family been recalled? (6 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 29, 2025Class IIZ-0716-2026Process controlPotential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).
Oct 29, 2025Class IIZ-0706-2026Process controlPotential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).
Oct 29, 2025Class IIZ-0707-2026Process controlPotential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).
Oct 29, 2025Class IIZ-0709-2026Process controlPotential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).
Jun 17, 2024Class IIZ-2376-2024Process controlPotential for the backcheck valve to malfunction, resulting in backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime, resulting in patient injuries of adverse drug reaction…
Jun 17, 2024Class IIZ-2404-2024Process controlPotential for the backcheck valve to malfunction, resulting in backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime, resulting in patient injuries of adverse drug reaction…
Jun 17, 2024Class IIZ-2377-2024Process controlPotential for the backcheck valve to malfunction, resulting in backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime, resulting in patient injuries of adverse drug reaction…
Aug 10, 2021Class IIZ-2556-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2551-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2555-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2546-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2557-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2544-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2550-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2545-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2554-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2558-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2549-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.
Aug 10, 2021Class IIZ-2547-2021Under Investigation by firmLeakage of the pump set within the cassette portion of the pump sets, potential for delays in administration of medications, under-delivery or incomplete dosing and bloodstream infections.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · 2 generations on · ◆ in the 2006 descendants bar of FIG. 11 Class I recall
  • K142036Infusomat Space Volumetric Infusion Pump Administration SetsB.Braun Medical, Inc. · 2014 · 3 generations on · ◆ in the 2014 descendants bar of FIG. 12 Class I recalls
  • K191910SpaceStation MRIB. Braun Melsugen AG · 2020 · 3 generations on · ◆ in the 2020 descendants bar of FIG. 13 Class I recalls
  • K121613Agilia Infusion SystemFresenius Kabi AG · 2013 · 3 generations on · ◆ in the 2013 descendants bar of FIG. 11 Class I recall
  • K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · 3 generations on · ◆ in the 2009 descendants bar of FIG. 11 Class I recall
  • K142596Infusomat Space Volumetric Infusion PumpB.Braun Medical, Inc. · 2015 · 4 generations on · ◆ in the 2015 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • Of its descendants, K972678 (Mcgaw, Inc., 1997) has gone furthest, with 16 descendants of its own.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—
Cite this page

510(k) Report. “K913661: Modified Volumetric Infusion Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K913661

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026