Infusomat Space Volumetric Infusion Pump System

K062700510(k) TraditionalCleared Oct 26, 200645-day reviewClass II21 CFR 880.5725Recalls 3 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

B.Braun Medical, Inc. · FRN Pump, Infusion

Cleared on Oct 26, 2006 as substantially equivalent to K023189 (B.Braun Medical, Inc., 2003) and 3 other predicates after a 45-day review. Its family tree reaches back 3 generations to 1990. 8 of the 34 devices in its family, counting itself, have a Class I recall. 15 later devices descend from it. It has been recalled 3 times, including a Class I recall.

Decided
Oct 26, 2006
Review
45 days
Class
Class II
Product code
FRN
Recalls
3 (1 Class I)
Predicates
4

Its longest line of descent runs back 3 generations to K904518 (1990). 18 ancestors in all, the oldest K820133 (1982). 15 later devices descend from it, 5 citing it directly. 8 of the 34 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2003: 1 other ancestor1997: 1 other ancestor1995: 1 other ancestor, 1 with a Class I recall11994: 3 other ancestors1993: 1 other ancestor1992: 2 other ancestors1991: 1 other ancestor1989: 1 other ancestor1986: 1 other ancestor1984: 2 other ancestors1982: 1 other ancestor2014: 2 descendants cleared, 1 with a Class I recall12020: 3 descendants cleared, 1 with a Class I recall12013: 1 descendant cleared, 1 with a Class I recall12009: 1 descendant cleared, 1 with a Class I recall12015: 1 descendant cleared, 1 with a Class I recall12022: 3 descendants cleared2016: 1 descendant cleared2017: 1 descendant cleared2025: 1 descendant cleared2021: 1 descendant clearedK904518 · Volumetric Infusion Pump · Kendall Mcgaw Laboratories, Inc. · 1990 · recalledK994375 · Horizon Light · B.Braun Medical, Inc. · 2000 · Class I recallK023189 · Vista Basic with FM System · B.Braun Medical, Inc. · 200319801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors, 1 with a Class I recall12 generations back: 11 other ancestors3 generations back: 1 other ancestor 1 generation forward: 5 descendants, 4 with a Class I recall42 generations forward: 6 descendants, 1 with a Class I recall13 generations forward: 4 descendants K023189 · Vista Basic with FM System · B.Braun Medical, Inc. · 2003K994375 · Horizon Light · B.Braun Medical, Inc. · 2000 · Class I recallK904518 · Volumetric Infusion Pump · Kendall Mcgaw Laboratories, Inc. · 1990 · recalled0
  1. Root · 3 generations backK904518 Volumetric Infusion PumpKendall Mcgaw Laboratories, Inc. · 1990 · Recalled
  2. 2 generations backK994375 Horizon LightB.Braun Medical, Inc. · 2000 · Recalled (Class I)
  3. 1 generation backK023189 Vista Basic with FM SystemB.Braun Medical, Inc. · 2003
  4. This deviceK062700 Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006
  5. Descendant · cites it directly · 6 of its ownK140838 IV Administration Set with Hand PumpB.Braun Medical, Inc. · 2014
  6. Descendant · cites it directly · 4 of its ownK083689 Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · Recalled (Class I)
  7. Descendant · 2 generations on · 3 of its ownK170595 IV Administration SetsB.Braun Medical, Inc. · 2017 · Recalled
  8. Descendant · cites it directly · 2 of its ownK121613 Agilia Infusion SystemFresenius Kabi AG · 2013 · Recalled (Class I)
  9. Descendant · 2 generations on · 1 of its ownK153731 LifeFlow Rapid Infusion Device (LifeFlow Device)410 Medical Innovation, LLC · 2016

Showing 5 of 15 descendants. See all descendants

Descendants cleared per year

2009: 12013: 12014: 22015: 12016: 12017: 12020: 32021: 12022: 32025: 1
2009high 3 (2020) · low 0 (2010)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 15 · See all
  • K140838IV Administration Set with Hand PumpB.Braun Medical, Inc. · 2014 · cites it directly6descendants
  • K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · cites it directly4descendants
  • K170595IV Administration SetsB.Braun Medical, Inc. · 2017 · 2 generations on3descendants
  • K121613Agilia Infusion SystemFresenius Kabi AG · 2013 · cites it directly2descendants
  • K153731LifeFlow Rapid Infusion Device (LifeFlow Device)410 Medical Innovation, LLC · 2016 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K904518Volumetric Infusion PumpKendall Mcgaw Laboratories, Inc.199037
−2K994375Horizon LightB.Braun Medical, Inc.2000Class I
−1K023189Vista Basic with FM SystemB.Braun Medical, Inc.2003—
0 (this device)K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc.2006—
+1K140838IV Administration Set with Hand PumpB.Braun Medical, Inc.2014—
+1K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc.2009Class I
+2K170595IV Administration SetsB.Braun Medical, Inc.201719
+1K121613Agilia Infusion SystemFresenius Kabi AG2013Class I
+2K153731LifeFlow Rapid Infusion Device (LifeFlow Device)410 Medical Innovation, LLC2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
198420
198610
198910
199110
199220
199310
199430
199511
199710
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200911
201311
201421
201511
201610
201710
202031
202110
202230
202510
FIG. 1 — Lineage of K062700, 1990–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

8 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023189Vista Basic with FM System
Summary page 1
…PREDICATE DEVICES: Predicate device for infusion pump: B. Braun Medical Inc. Vista Basic withfin System 5 10(k) K023 189; ALARIS Medical Systems, Alaris MedleyTm Patient Care System 51…
B.Braun Medical, Inc.2003—
*K030459Medley System with Medication Management System (MMS)
Summary page 1
…sic withfin System 5 10(k) K023 189; ALARIS Medical Systems, Alaris MedleyTm Patient Care System 510(k) K030459, ALARIS Medical Systems, Alaris MEDLEYT Pump Module 510(k) K9504 19.…
Alaris Medical Systems, Inc.2003—
*K950419The Imed Orion Infusion Pump and Administration Sets
Summary page 1
…MedleyTm Patient Care System 510(k) K030459, ALARIS Medical Systems, Alaris MEDLEYT Pump Module 510(k) K9504 19. Predicate device for administration sets: B. Braun Medical Inc…
Imed Corp.1995Class I
*K972678Millennium CRT Infusion Pump and Millennium CRT Infusion Pump Administration Sets
Summary page 1
…n Medical Inc. Millennium CRT Infusion Pump and Millennium CRT Infusion Pump Administration Sets 510(k) K972678. DESCRIPTION: The Infusomat® Space Volumetric Infusion Pump System includes…
Mcgaw, Inc.1997—

What descends from it? (15)

See all 15

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K140838IV Administration Set with Hand PumpB.Braun Medical, Inc.20146
K083689Infusomat Space Volumetric Infusion Pump System Class IB.Braun Medical, Inc.20094
K121613Agilia Infusion System Class IFresenius Kabi AG20132
K142036Infusomat Space Volumetric Infusion Pump Administration Sets Class IB.Braun Medical, Inc.20141
K191910SpaceStation MRI Class IB. Braun Melsugen AG20200

Has anything in its family been recalled? (8 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 23, 2012Class IIZ-0623-2013Device DesignFirm has become aware of the potential for breakage of the pole clamp locking grids, or rasters, in the Space Pole Clamps.
Mar 23, 2012Class IZ-1992-2012Device DesignFirm became aware of the potential for breakage of the anti free flow clip catch, located on the inside of the pump door, when the IV set anti free flow clip is incorrectly inserted into the pump and the pump door forced closed. If the…
Jul 12, 2011Not classifiedZ-1015-2012Device DesignIf the IV set anti free flow clip is incorrectly inserted into the pump and the pump door forced closed, the clip catch on the inside of the pump door may break. If the clip catch is broken and the door opened, free flow protection is…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K950419The Imed Orion Infusion Pump and Administration SetsImed Corp. · 1995 · Direct predicate · ◆ in the 1995 ancestors bar of FIG. 14 Class I recalls
  • K994375Horizon LightB.Braun Medical, Inc. · 2000 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall
  • K142036Infusomat Space Volumetric Infusion Pump Administration SetsB.Braun Medical, Inc. · 2014 · Cites it directly · ◆ in the 2014 descendants bar of FIG. 12 Class I recalls
  • K191910SpaceStation MRIB. Braun Melsugen AG · 2020 · Cites it directly · ◆ in the 2020 descendants bar of FIG. 13 Class I recalls
  • K121613Agilia Infusion SystemFresenius Kabi AG · 2013 · Cites it directly · ◆ in the 2013 descendants bar of FIG. 11 Class I recall
  • K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · Cites it directly · ◆ in the 2009 descendants bar of FIG. 11 Class I recall
  • K142596Infusomat Space Volumetric Infusion PumpB.Braun Medical, Inc. · 2015 · 2 generations on · ◆ in the 2015 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 16 years and passes through 2 companies; a new generation was cleared every 3.6 years on median.
  • 9 of the 18 ancestors have a recall of any class; 2 have a Class I recall.
  • Of its descendants, K140838 (B.Braun Medical, Inc., 2014) has gone furthest, with 6 descendants of its own.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The Infusomat® Space Volumetric Infusion Pump System includes an external transportable electronic volumetric infusion pump, dedicated administration sets, and pump accessories. The system is intended for use on adults, pediatrics, and neonates for the intermittent or continuous delivery of parenteral and enteral fluids through clinically accepted routes of administration. These routes include, but are not limited to intravenous, irrigation/ablation, and…

Read the full statement (123 words)

The Infusomat® Space Volumetric Infusion Pump System includes an external transportable electronic volumetric infusion pump, dedicated administration sets, and pump accessories. The system is intended for use on adults, pediatrics, and neonates for the intermittent or continuous delivery of parenteral and enteral fluids through clinically accepted routes of administration. These routes include, but are not limited to intravenous, irrigation/ablation, and enteral. The system is used for the delivery of medications indicated for infusion therapy including but not limited to colloids and crystalloids, blood and blood components, Total Parenteral Nutrition (TPN), lipids, and enteral fluids. The Infusomat® Space Volumetric Infusion Pump System is intended to be used by trained healthcare professionals in healthcare facilities, home care, outpatient, and medical transport environments (only road ambulances).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062700: Infusomat Space Volumetric Infusion Pump System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K062700

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026