510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

Brilliance CT, Private Practice CV Configuration, CT Scanner

K042293510(k) TraditionalCleared Sep 8, 200415-day reviewClass II21 CFR 892.1750Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems (Cleveland), Inc. · JAK System, X-Ray, Tomography, Computed

Cleared on Sep 8, 2004 as substantially equivalent to K033326 (Philips Medical Systems, Inc., 2003) and 1 other predicate after a 15-day review. Its family tree reaches back 5 generations to 1993. 147 later devices descend from it. It has been recalled once.

Decided
Sep 8, 2004
Review
15 days
Class
Class II
Product code
JAK
Recalls
1
Predicates
2

Its longest line of descent runs back 5 generations to K930090 (1993). 10 ancestors in all. 147 later devices descend from it, 6 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1997: 1 other ancestor1995: 1 other ancestor1994: 2 other ancestors2006: 1 descendant cleared2013: 3 descendants cleared2011: 2 descendants cleared2010: 1 descendant cleared2005: 1 descendant cleared2009: 1 descendant cleared2017: 5 descendants cleared2024: 15 descendants cleared2012: 3 descendants cleared2014: 4 descendants cleared2022: 17 descendants cleared2025: 26 descendants cleared2019: 6 descendants cleared2023: 12 descendants cleared2026: 20 descendants cleared2018: 7 descendants cleared2020: 15 descendants cleared2021: 8 descendants clearedK930090 · Helicat · Elscint, Inc. · 1993K961464 · Select/SP · Elscint, Inc. · 1996 · recalledK982060 · Volumax CT Imaging System · Elscint, Inc. · 1998K012009 · MX8000 Idt CT System · Marconi Medical Systems, Inc. · 2001 · recalledK033326 · Philips Plus Computed Tomography System · Philips Medical Systems, Inc. · 2003 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 3 other ancestors4 generations back: 1 other ancestor 1 generation forward: 6 descendants2 generations forward: 8 descendants3 generations forward: 15 descendants4 generations forward: 20 descendants5 generations forward: 21 descendants6 generations forward: 24 descendants7 generations forward: 16 descendants8 generations forward: 11 descendants9 generations forward: 7 descendants10 generations forward: 10 descendants11 generations forward: 6 descendants12 generations forward: 2 descendants13 generations forward: 1 descendant K033326 · Philips Plus Computed Tomography System · Philips Medical Systems, Inc. · 2003 · recalledK012009 · MX8000 Idt CT System · Marconi Medical Systems, Inc. · 2001 · recalledK982060 · Volumax CT Imaging System · Elscint, Inc. · 1998K961464 · Select/SP · Elscint, Inc. · 1996 · recalledK930090 · Helicat · Elscint, Inc. · 1993−50+5+10
  1. Root · 5 generations backK930090 HelicatElscint, Inc. · 1993
  2. 4 generations backK961464 Select/SPElscint, Inc. · 1996 · Recalled
  3. 3 generations backK982060 Volumax CT Imaging SystemElscint, Inc. · 1998
  4. 2 generations backK012009 MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · Recalled
  5. 1 generation backK033326 Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc. · 2003 · Recalled
  6. This deviceK042293 Brilliance CT, Private Practice CV Configuration, CT ScannerPhilips Medical Systems (Cleveland), Inc. · 2004
  7. Descendant · cites it directly · 92 of its ownK130159 Qlab Quantification Software Heart ModelPhilips Health Care · 2013
  8. Descendant · 2 generations on · 91 of its ownK132165 Qlab Quantification SoftwarePhilips Ultrasound, Inc. · 2013 · Recalled
  9. Descendant · cites it directly · 49 of its ownK062650 EP Navigator SoftwarePhilips Medical Systems · 2006
  10. Descendant · 3 generations on · 45 of its ownK171314 QLAB Advanced Quantification SoftwarePhilips Health Care · 2017
  11. Descendant · 4 generations on · 44 of its ownK181264 QLAB Advanced Quantification SoftwarePhilips Ultrasound, Inc. · 2018

Showing 5 of 147 descendants. See all descendants

Descendants cleared per year

2005: 12006: 12009: 12010: 12011: 22012: 32013: 32014: 42017: 52018: 72019: 62020: 152021: 82022: 172023: 122024: 152025: 262026: 20
2005high 26 (2025) · low 0 (2007)2026

Most influential descendants

Showing 5 of 147 · See all
  • K130159Qlab Quantification Software Heart ModelPhilips Health Care · 2013 · cites it directly92descendants
  • K132165Qlab Quantification SoftwarePhilips Ultrasound, Inc. · 2013 · 2 generations on91descendants
  • K062650EP Navigator SoftwarePhilips Medical Systems · 2006 · cites it directly49descendants
  • K171314QLAB Advanced Quantification SoftwarePhilips Health Care · 2017 · 3 generations on45descendants
  • K181264QLAB Advanced Quantification SoftwarePhilips Ultrasound, Inc. · 2018 · 4 generations on44descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K930090HelicatElscint, Inc.1993—
−4K961464Select/SPElscint, Inc.19963
−3K982060Volumax CT Imaging SystemElscint, Inc.1998—
−2K012009MX8000 Idt CT SystemMarconi Medical Systems, Inc.200161
−1K033326Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc.2003131
0 (this device)K042293Brilliance CT, Private Practice CV Configuration, CT ScannerPhilips Medical Systems (Cleveland), Inc.2004—
+1K130159Qlab Quantification Software Heart ModelPhilips Health Care2013—
+2K132165Qlab Quantification SoftwarePhilips Ultrasound, Inc.20131
+1K062650EP Navigator SoftwarePhilips Medical Systems2006—
+3K171314QLAB Advanced Quantification SoftwarePhilips Health Care2017—
+4K181264QLAB Advanced Quantification SoftwarePhilips Ultrasound, Inc.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199510
199710
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200610
200910
201010
201120
201230
201330
201440
201750
201870
201960
2020150
202180
2022170
2023120
2024150
2025260
2026200
FIG. 1 — Lineage of K042293, 1993–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K033326Philips Plus Computed Tomography System
Summary page 2
…is of comparable type and substantially equivalent to the legally marketed devices currently in commercial distribution, namely: * Brilliance CT (Philips Plus, K033326) * Mx8000 IDT, K012009 6. Safety and Effectiveness Considerations The safety of the device is assured by adherence to…
Philips Medical Systems, Inc.2003131
*K012009MX8000 Idt CT System
Summary page 2
…tantially equivalent to the legally marketed devices currently in commercial distribution, namely: * Brilliance CT (Philips Plus, K033326) * Mx8000 IDT, K012009 6. Safety and Effectiveness Considerations The safety of the device is assured by adherence to GMP practices and to Internati…
Marconi Medical Systems, Inc.200161

Also cleared against K033326: 8 other devices →

What descends from it? (147)

See all 147

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K130159Qlab Quantification Software Heart ModelPhilips Health Care201392
K062650EP Navigator SoftwarePhilips Medical Systems200649
K101311EP Navigator R3Philips Medical Systems North America Co.201041
K092747Philips Comprehensive Cardiac Analysis (Cca) - Plaque Assessment ToolPhilips Medical Systems (Cleveland), Inc.200919
K1125303DI Including CscoreShina Systems, Ltd.20111
K051351Precedence Spect/CT Imaging SystemAdac Laboratories20050

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 24, 2019Class IIZ-2191-2019OtherIn certain instances when performing a cardiac step and shoot acquisition with phase tolerance selected, images may be labeled as if phase tolerance had been applied when phase tolerance had not been applied

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 4 companies; a new generation was cleared every 2.2 years on median.
  • 4 of the 10 ancestors have a recall of any class.
  • Of its descendants, K130159 (Philips Health Care, 2013) has gone furthest, with 92 descendants of its own.
  • 8 other devices also cite its predicate K033326.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The Philips Brilliance CT in the Private Practice CV configuration is a Computed Tomography X-Ray System intended to produce images of the heart, cardiovascular (including pulmonary veins) and peripheral vascular systems (including the carotids, renals, aorta, iliac, and other distal vessels imaged by angiographic run-off procedures) by computer reconstruction of x-ray transmission data taken at different angles and planes. This device may include signal analysis and display equipment, patient and equipment supports, components and accessories

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042293: Brilliance CT, Private Practice CV Configuration, CT Scanner.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K042293

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026