510(k) Report

510(k) · Cleared

Cleared

Infant Flow System

K991972510(k) SpecialCleared Aug 13, 199963-day reviewClass II21 CFR 868.5905

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sensor Medics Corp. · BZD Ventilator, Non-Continuous (Respirator)

Cleared on Aug 13, 1999 after a 63-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 9 of the 25 devices in its family, counting itself, have a Class I recall. 24 later devices descend from it.

Decided
Aug 13, 1999
Review
63 days
Class
Class II
Product code
BZD
Recalls
None
Predicates
0

24 later devices descend from it, 2 citing it directly. 9 of the 25 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2001: 1 descendant cleared2004: 1 descendant cleared2006: 1 descendant cleared2008: 2 descendants cleared, 1 with a Class I recall12007: 1 descendant cleared2012: 6 descendants cleared, 2 with a Class I recall22013: 1 descendant cleared, 1 with a Class I recall12009: 1 descendant cleared2011: 1 descendant cleared2015: 1 descendant cleared2017: 2 descendants cleared, 1 with a Class I recall12019: 1 descendant cleared, 1 with a Class I recall12016: 1 descendant cleared, 1 with a Class I recall12021: 1 descendant cleared, 1 with a Class I recall12020: 1 descendant cleared, 1 with a Class I recall12024: 1 descendant cleared2026: 1 descendant cleared1995200020052010201520202025
  1. This deviceK991972 Infant Flow SystemSensor Medics Corp. · 1999
  2. Descendant · cites it directly · 22 of its ownK031745 Infant Flow Plus Infant Cpap System with Sipap FunctionSensor Medics Corp. · 2004
  3. Descendant · 2 generations on · 21 of its ownK062093 Avea VentilatorViasys Respiratory Care, Inc. · 2006 · Recalled
  4. Descendant · 3 generations on · 16 of its ownK081521 Modification to Hamilton-G5Hamilton Medical AG · 2008 · Recalled (Class I)
  5. Descendant · 4 generations on · 14 of its ownK102775 Hamilton-C2Hamilton Medical AG · 2011
  6. Descendant · 5 generations on · 13 of its ownK112006 Hamilton-TC1Hamilton Medical AG · 2012

Showing 5 of 24 descendants. See all descendants

Descendants cleared per year

2001: 12004: 12006: 12007: 12008: 22009: 12011: 12012: 62013: 12015: 12016: 12017: 22019: 12020: 12021: 12024: 12026: 1
2001high 6 (2012) · low 0 (2002)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 24 · See all
  • K031745Infant Flow Plus Infant Cpap System with Sipap FunctionSensor Medics Corp. · 2004 · cites it directly22descendants
  • K062093Avea VentilatorViasys Respiratory Care, Inc. · 2006 · 2 generations on21descendants
  • K081521Modification to Hamilton-G5Hamilton Medical AG · 2008 · 3 generations on16descendants
  • K102775Hamilton-C2Hamilton Medical AG · 2011 · 4 generations on14descendants
  • K112006Hamilton-TC1Hamilton Medical AG · 2012 · 5 generations on13descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K991972Infant Flow SystemSensor Medics Corp.1999—
+1K031745Infant Flow Plus Infant Cpap System with Sipap FunctionSensor Medics Corp.2004—
+2K062093Avea VentilatorViasys Respiratory Care, Inc.20065
+3K081521Modification to Hamilton-G5Hamilton Medical AG2008Class I
+4K102775Hamilton-C2Hamilton Medical AG2011—
+5K112006Hamilton-TC1Hamilton Medical AG2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200110
200410
200610
200710
200821
200910
201110
201262
201311
201510
201611
201721
201911
202011
202111
202410
202610
FIG. 1 — Lineage of K991972, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

9 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZD device

  1. #1 K250624 myAirscore 15.7 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (24)

See all 24

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K031745Infant Flow Plus Infant Cpap System with Sipap FunctionSensor Medics Corp.200422
K012034Modification to: Sipap Infant Nasal Cpap CircuitSensor Medics Corp.20010

Has anything in its family been recalled? (9 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K081521Modification to Hamilton-G5Hamilton Medical AG · 2008 · 3 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
  • K130178Inspiration Ventilator System 5I/7IeVent Medical, Ltd. · 2013 · 4 generations on · ◆ in the 2013 descendants bar of FIG. 11 Class I recall
  • K121225Hamilton-C2Hamilton Medical AG · 2012 · 5 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K120670Hamilton-T1Hamilton Medical AG · 2012 · 6 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K162832731 Series VentilatorsZOLL Medical Corporation · 2017 · 7 generations on · ◆ in the 2017 descendants bar of FIG. 11 Class I recall
  • K181216Hamilton-T1, Hamilton-C1Hamilton Medical AG · 2019 · 7 generations on · ◆ in the 2019 descendants bar of FIG. 15 Class I recalls
  • K153046Hamilton-MR1Hamilton Medical AG · 2016 · 7 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall
  • K201306Hamilton-C3Hamilton Medical AG · 2021 · 8 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall
  • K201658Hamilton-C6Hamilton Medical AG · 2020 · 8 generations on · ◆ in the 2020 descendants bar of FIG. 13 Class I recalls

What does this lineage say?

  • Of its descendants, K031745 (Sensor Medics Corp., 2004) has gone furthest, with 22 descendants of its own.

How does its category compare?

All BZD devices

BZD Ventilator, Non-Continuous (Respirator): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BZD

7in 2025

2007: 212008: 172009: 232010: 122011: 232012: 212013: 232014: 142015: 112016: 122017: 52018: 52019: 62020: 62021: 62022: 42023: 52024: 102025: 72026 (partial year): 10
2007high 23 (2009) · low 4 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZD

189in 2025

2007: 83 days median2008: 108 days median2009: 90 days median2010: 122 days median2011: 125 days median2012: 133 days median2013: 127 days median2014: 172 days median2015: 224 days median2016: 217 days median2017: 221 days median2018: 280 days median2019: 231 days median2020: 137 days median2021: 192 days median2022: 253 days median2023: 204 days median2024: 132 days median2025: 189 days median2026 (partial year): 214 days median
2007high 280 (2018) · low 83 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZD

8in 2023

2007: 292008: 22009: 12011: 12019: 4, 4 Class I2023: 8, 7 Class I2026 (partial year): 2, 2 Class I
2007high 29 (2007) · low 0 (2010)2026

Class I (13 since 2007) Class II/III not classified

Adverse event reports per year · BZD

60,279in 2025

2007: 652008: 672009: 1472010: 1432011: 1892012: 1392013: 822014: 862015: 1142016: 1182017: 1482018: 1012019: 1882020: 1262021: 6,0662022: 90,7682023: 27,9872024: 68,2622025: 60,279
2007high 90,768 (2022) · low 65 (2007)2025

MAUDE reports naming product code BZD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200721832965
200817108267
200923901147
2010121220143
2011231251189
2012211330139
201323127082
201414172086
2015112240114
2016122170118
201752210148
201852800101
201962314 (4)188
202061370126
2021619206,066
20224253090,768
202352048 (7)27,987
202410132068,262
20257189060,279
2026102142 (2)—

What is it indicated for?

The SensorMedics Infant Flow System, consisting of a Driver and NCPAP Prongs, is intended to provide CPAP for use in hospitals to treat newborns and infants with RDS or who are recovering from RDS.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K991972: Infant Flow System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K991972

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.