510(k) Report

510(k) · Cleared

Cleared

Pharmguard Toolbox, Model G6000782

K042432510(k) TraditionalCleared Jan 4, 2005118-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medex, Inc. · FRN Pump, Infusion

Cleared on Jan 4, 2005 after a 118-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 3 of the 6 devices in its family, counting itself, have a Class I recall. 5 later devices descend from it.

Decided
Jan 4, 2005
Review
118 days
Class
Class II
Product code
FRN
Recalls
None
Predicates
0

5 later devices descend from it, 1 citing it directly. 3 of the 6 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2011: 1 descendant cleared, 1 with a Class I recall12016: 2 descendants cleared2022: 1 descendant cleared, 1 with a Class I recall12024: 1 descendant cleared, 1 with a Class I recall120052010201520202025
  1. This deviceK042432 Pharmguard Toolbox, Model G6000782Medex, Inc. · 2005
  2. Descendant · cites it directly · 4 of its ownK111386 Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2…Smiths Medical MD, Inc. · 2011 · Recalled (Class I)
  3. Descendant · 2 generations on · 1 of its ownK211125 Novum IQ Syringe PumpBaxter Healthcare Corporation · 2022 · Recalled (Class I)
  4. Descendant · 2 generations on · 1 of its ownK160482 t:slim Insulin Delivery System, t:flex Insulin Delivery System…Tandem Diabetes Care, Inc. · 2016
  5. Descendant · 3 generations on · 0 of its ownK242390 Novum IQ Syringe Pump (40800BAXUS)Baxter Healthcare Corporation · 2024 · Recalled (Class I)
  6. Descendant · 3 generations on · 0 of its ownK162080 t:slim Insulin Delivery System, t:flex Insulin Delivery System…Tandem Diabetes Care, Inc. · 2016

Class I recalls in this family

Most influential descendants

Showing 5 of 5 · See all
  • K111386Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication Safety…Smiths Medical MD, Inc. · 2011 · cites it directly4descendants
  • K211125Novum IQ Syringe PumpBaxter Healthcare Corporation · 2022 · 2 generations on1descendant
  • K160482t:slim Insulin Delivery System, t:flex Insulin Delivery System, Tandem Device UpdaterTandem Diabetes Care, Inc. · 2016 · 2 generations on1descendant
  • K242390Novum IQ Syringe Pump (40800BAXUS)Baxter Healthcare Corporation · 2024 · 3 generations on0descendants
  • K162080t:slim Insulin Delivery System, t:flex Insulin Delivery System, Tandem Device UpdaterTandem Diabetes Care, Inc. · 2016 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K042432Pharmguard Toolbox, Model G6000782Medex, Inc.2005—
+1K111386Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication…Smiths Medical MD, Inc.2011Class I
+2K211125Novum IQ Syringe PumpBaxter Healthcare Corporation2022Class I
+2K160482t:slim Insulin Delivery System, t:flex Insulin Delivery System, Tandem Device…Tandem Diabetes Care, Inc.2016—
+3K242390Novum IQ Syringe Pump (40800BAXUS)Baxter Healthcare Corporation2024Class I
+3K162080t:slim Insulin Delivery System, t:flex Insulin Delivery System, Tandem Device…Tandem Diabetes Care, Inc.2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201111
201620
202211
202411
FIG. 1 — Lineage of K042432, 2005–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (5)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K111386Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication Safety… Class ISmiths Medical MD, Inc.20114

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K111386Medfusion Model 4000 Syringe Infusion Pump, Pharmguard Toolbox 2 Medication Safety Software and Supported…Smiths Medical MD, Inc. · 2011 · Cites it directly · ◆ in the 2011 descendants bar of FIG. 16 Class I recalls
  • K211125Novum IQ Syringe PumpBaxter Healthcare Corporation · 2022 · 2 generations on · ◆ in the 2022 descendants bar of FIG. 11 Class I recall
  • K242390Novum IQ Syringe Pump (40800BAXUS)Baxter Healthcare Corporation · 2024 · 3 generations on · ◆ in the 2024 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Of its descendants, K111386 (Smiths Medical MD, Inc., 2011) has gone furthest, with 4 descendants of its own.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

PharmGuard Toolbox is intended to provide a vehicle to create and securely upload user-defined configuration parameters, a library of drug names and associated user-defined infusion parameters to Medex Infusion Pumps. The PharmGuard Toolbox collects and downloads operational, infusion, and alarm history events, library usage counts, and PharmGuard safety events from compatible Medex Infusion Pumps. It is intended to provide a rich dataset users can collect and analyze to improve overall processes and lessen the likelihood of operator error when entering infusion parameters into the Medex Infusion Pumps.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K042432: Pharmguard Toolbox, Model G6000782.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K042432

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026