The Imed Orion Infusion Pump and Administration Sets

K950419510(k) TraditionalCleared Jun 21, 1995141-day reviewClass II21 CFR 880.5725Recalls 12 (4 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Imed Corp. · FRN Pump, Infusion

Cleared on Jun 21, 1995 after a 141-day review. The FDA summary names its predicate without a number. 10 of the 30 devices in its family, counting itself, have a Class I recall. 29 later devices descend from it. It has been recalled 12 times, including 4 Class I recalls.

Decided
Jun 21, 1995
Review
141 days
Class
Class II
Product code
FRN
Recalls
12 (4 Class I)
Predicates
0

29 later devices descend from it, 5 citing it directly. 10 of the 30 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2006: 2 descendants cleared, 1 with a Class I recall12003: 1 descendant cleared2005: 1 descendant cleared, 1 with a Class I recall12002: 1 descendant cleared2014: 3 descendants cleared, 2 with a Class I recall22009: 3 descendants cleared, 1 with a Class I recall12020: 3 descendants cleared, 1 with a Class I recall12013: 1 descendant cleared, 1 with a Class I recall12022: 4 descendants cleared2023: 1 descendant cleared, 1 with a Class I recall12012: 2 descendants cleared2018: 1 descendant cleared2015: 1 descendant cleared, 1 with a Class I recall12016: 1 descendant cleared2017: 1 descendant cleared2025: 2 descendants cleared2021: 1 descendant cleared1995200020052010201520202025
  1. This deviceK950419 The Imed Orion Infusion Pump and Administration SetsImed Corp. · 1995
  2. Descendant · cites it directly · 16 of its ownK023189 Vista Basic with FM SystemB.Braun Medical, Inc. · 2003
  3. Descendant · cites it directly · 15 of its ownK062700 Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · Recalled (Class I)
  4. Descendant · 2 generations on · 6 of its ownK140838 IV Administration Set with Hand PumpB.Braun Medical, Inc. · 2014
  5. Descendant · cites it directly · 6 of its ownK051641 Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products · 2005 · Recalled (Class I)
  6. Descendant · 2 generations on · 5 of its ownK091308 Alaris PC Unit, Models 8000 and 8015Cardinal Health 303,Inc. · 2009

Showing 5 of 29 descendants. See all descendants

Descendants cleared per year

2002: 12003: 12005: 12006: 22009: 32012: 22013: 12014: 32015: 12016: 12017: 12018: 12020: 32021: 12022: 42023: 12025: 2
2002high 4 (2022) · low 0 (2004)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 29 · See all
  • K023189Vista Basic with FM SystemB.Braun Medical, Inc. · 2003 · cites it directly16descendants
  • K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · cites it directly15descendants
  • K140838IV Administration Set with Hand PumpB.Braun Medical, Inc. · 2014 · 2 generations on6descendants
  • K051641Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products · 2005 · cites it directly6descendants
  • K091308Alaris PC Unit, Models 8000 and 8015Cardinal Health 303,Inc. · 2009 · 2 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K950419The Imed Orion Infusion Pump and Administration SetsImed Corp.1995—
+1K023189Vista Basic with FM SystemB.Braun Medical, Inc.2003—
+1K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc.2006Class I
+2K140838IV Administration Set with Hand PumpB.Braun Medical, Inc.2014—
+1K051641Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products2005Class I
+2K091308Alaris PC Unit, Models 8000 and 8015Cardinal Health 303,Inc.2009—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200511
200621
200931
201220
201311
201432
201511
201610
201710
201810
202031
202110
202240
202311
202520
FIG. 1 — Lineage of K950419, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

10 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—IMED Gemini PC-2TX Infusion Pump and Administration Sets
Named without a submission number
—

What descends from it? (29)

See all 29

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K023189Vista Basic with FM SystemB.Braun Medical, Inc.200316
K062700Infusomat Space Volumetric Infusion Pump System Class IB.Braun Medical, Inc.200615
K051641Alaris System PC Unit, Model 8001 Class ICardinal Health, Alaris Products20056
K022575Perfusor Compact with FM SystemB.Braun Medical, Inc.20025
K133532Alaris System with Guardrails Suite MX Class ICarefusion 303, Inc.20143

Has anything in its family been recalled? (10 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 9, 2017Class IIZ-0026-2018Unknown/Undetermined by firmThe recalling firm has received reports of increased or decreased flows that have occurred in certain pumps.
Jun 12, 2017Class IIZ-2700-2017Device DesignThere is a potential risk that could cause unintended flow in the older, centered sear door latch design in the Alaris Pump module model 8100.
Dec 2, 2016Class IZ-0950-2017Component change controlDuring an infusion, a false Air-in-Line (AIL) alarm would cause the infusion to be interrupted.
Apr 23, 2014Class IZ-1567-2014Software designCareFusion is recalling the Alaris Pump model 8100 version 9.1.18 because it may have a software issue that results in situation where the pump module will not properly delay an infusion when the "Delay Until" option or "Multidose"…
Jun 29, 2012Class IZ-2185-2012Under Investigation by firmThe recall was initiated because Carefusion identified a potential risk associated with the Alaris Pump module model 8100. Carefusion has received reports of customers experiencing motor stalls during infusion with Alaris Pump Module…
Jun 15, 2012Class IZ-2205-2012Device DesignThe recall was initiated because Carefusion has identified a potential risk associated with the Alaris Pump module model 8100. The pump module door keypad overlay may separate from the keypad assembly
Jun 12, 2009Not classifiedZ-1794-2009Device DesignThere is a potential risk of IUI connector failure in the Alaris System when these connectors become corroded or contaminated, which may result in an interruption of infusion with an audible and visual alarm. IUI connectors can become…
Jun 12, 2009Not classifiedZ-1793-2009Device DesignThere is a potential risk of over infusion when certain fluids solidify in the pumping mechanism of the Alaris Pump module. This notification is to reinforce the importance of proper techniques for IV set loading and cleaning. When IV…
Mar 5, 2008Not classifiedZ-1712-2008Device DesignA channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors due to failure of the U9 Socketed Integrated Circuits (U9 IC) on the display board of the…
Mar 5, 2008Not classifiedZ-1710-2008Device DesignA channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors due to failures of the U19 Socketed Integrated Circuits (U19 IC) on the logic board of the…
Mar 5, 2008Not classifiedZ-1711-2008Device DesignA channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors with the Alaris System due to the Inter-Unit Interface (IUI) connectors on all Alaris System…
Nov 10, 2004Not classifiedZ-0568-05OtherThe device modification is being implemented in response to information received from the field regarding a specific method of misloading the medication administration tubing set into the infusion system pump module. To date there have…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · Cites it directly · ◆ in the 2006 descendants bar of FIG. 11 Class I recall
  • K051641Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products · 2005 · Cites it directly · ◆ in the 2005 descendants bar of FIG. 110 Class I recalls
  • K133532Alaris System with Guardrails Suite MXCarefusion 303, Inc. · 2014 · Cites it directly · ◆ in the 2014 descendants bar of FIG. 128 Class I recalls
  • K142036Infusomat Space Volumetric Infusion Pump Administration SetsB.Braun Medical, Inc. · 2014 · 2 generations on · ◆ in the 2014 descendants bar of FIG. 12 Class I recalls
  • K191910SpaceStation MRIB. Braun Melsugen AG · 2020 · 2 generations on · ◆ in the 2020 descendants bar of FIG. 13 Class I recalls
  • K121613Agilia Infusion SystemFresenius Kabi AG · 2013 · 2 generations on · ◆ in the 2013 descendants bar of FIG. 11 Class I recall
  • K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · 2 generations on · ◆ in the 2009 descendants bar of FIG. 11 Class I recall
  • K211218BD Alaris System with Guardrails Suite MX v12.1.2Carefusion 303, Inc. · 2023 · 2 generations on · ◆ in the 2023 descendants bar of FIG. 17 Class I recalls
  • K142596Infusomat Space Volumetric Infusion PumpB.Braun Medical, Inc. · 2015 · 3 generations on · ◆ in the 2015 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • Of its descendants, K023189 (B.Braun Medical, Inc., 2003) has gone furthest, with 16 descendants of its own.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The Orion™ Infusion System is intended for use in a health care facility t0 pump standard 1V fluids, medications, whole blood and packed red blood cells into a patientin a controlled manner. The system is electrically powered, with back up battery power available, and uses linear peristaltic pumping action to infuse fluids. The Orion System is capable of detecting air-in-line and occlusions. The Orion System is also indicated for Epidural infusions. Appropriate warnings and precautions 10 safely and accurately infuse Epidural are provided in the product labeling.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K950419: The Imed Orion Infusion Pump and Administration Sets.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K950419

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026