Modification to Neuviz Dual Multi-Slice CT Scanner System

K071308510(k) TraditionalCleared Aug 16, 200799-day reviewClass II21 CFR 892.1750Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Neusoft Medical Systems Co., Ltd. · JAK System, X-Ray, Tomography, Computed

Cleared on Aug 16, 2007 as substantially equivalent to K062451 (Neusoft Medical Systems Co., Ltd., 2006) and 1 other predicate after a 99-day review. Its family tree reaches back 5 generations to 1993. 1 later device descends from it. It has been recalled 7 times.

Decided
Aug 16, 2007
Review
99 days
Class
Class II
Product code
JAK
Recalls
7
Predicates
2

Its longest line of descent runs back 5 generations to K930090 (1993). 13 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2006: 1 other ancestor2004: 1 other ancestor2001: 1 other ancestor2002: 1 other ancestor1997: 1 other ancestor1995: 1 other ancestor1994: 2 other ancestors2008: 1 descendant clearedK930090 · Helicat · Elscint, Inc. · 1993K961464 · Select/SP · Elscint, Inc. · 1996 · recalledK982060 · Volumax CT Imaging System · Elscint, Inc. · 1998K012009 · MX8000 Idt CT System · Marconi Medical Systems, Inc. · 2001 · recalledK033326 · Philips Plus Computed Tomography System · Philips Medical Systems, Inc. · 2003 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors3 generations back: 1 other ancestor4 generations back: 3 other ancestors5 generations back: 1 other ancestor 1 generation forward: 1 descendant K033326 · Philips Plus Computed Tomography System · Philips Medical Systems, Inc. · 2003 · recalledK012009 · MX8000 Idt CT System · Marconi Medical Systems, Inc. · 2001 · recalledK982060 · Volumax CT Imaging System · Elscint, Inc. · 1998K961464 · Select/SP · Elscint, Inc. · 1996 · recalledK930090 · Helicat · Elscint, Inc. · 1993−50
  1. Root · 5 generations backK930090 HelicatElscint, Inc. · 1993
  2. 4 generations backK961464 Select/SPElscint, Inc. · 1996 · Recalled
  3. 3 generations backK982060 Volumax CT Imaging SystemElscint, Inc. · 1998
  4. 2 generations backK012009 MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · Recalled
  5. 1 generation backK033326 Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc. · 2003 · Recalled
  6. This deviceK071308 Modification to Neuviz Dual Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd. · 2007
  7. Descendant · cites it directly · 0 of its ownK080540 Neusoft Spiral CT Scanner System, Model Neuviz Version 2.0Neusoft Medical Systems Co., Ltd. · 2008

Most influential descendants

Showing 1 of 1 · See all
  • K080540Neusoft Spiral CT Scanner System, Model Neuviz Version 2.0Neusoft Medical Systems Co., Ltd. · 2008 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K930090HelicatElscint, Inc.1993—
−4K961464Select/SPElscint, Inc.19963
−3K982060Volumax CT Imaging SystemElscint, Inc.1998—
−2K012009MX8000 Idt CT SystemMarconi Medical Systems, Inc.200161
−1K033326Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc.2003131
0 (this device)K071308Modification to Neuviz Dual Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd.2007—
+1K080540Neusoft Spiral CT Scanner System, Model Neuviz Version 2.0Neusoft Medical Systems Co., Ltd.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199510
199710
200110
200210
200410
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
FIG. 1 — Lineage of K071308, 1993–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K062451Neuviz Dual Multi-Slice CT Scanner System
Summary page 3
…taneously. The system software is an interactive program used for X-ray scan control, image reconstruction, and image archive/evaluation. Predicated Device: K062451: NeuViz Dual Systems K033326: Philips Plus CT Scanner Statement of Substantial Equivalence: The NeuViz Dual (modified…
Neusoft Medical Systems Co., Ltd.20066
*K033326Philips Plus Computed Tomography System
Summary page 3
…an interactive program used for X-ray scan control, image reconstruction, and image archive/evaluation. Predicated Device: K062451: NeuViz Dual Systems K033326: Philips Plus CT Scanner Statement of Substantial Equivalence: The NeuViz Dual (modified) systems are of comparable type a…
Philips Medical Systems, Inc.2003131

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K080540Neusoft Spiral CT Scanner System, Model Neuviz Version 2.0Neusoft Medical Systems Co., Ltd.20080

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 4, 2013Class IIZ-1166-2013Use errorUser error of the NeuViz 16 or NeuViz Dual may cause personnel injuries. There was a report where a finger was pinched when the table was moved backward while the tabletop was controlled by another person from the gantry left control panel.
Oct 18, 2012Class IIZ-0466-2013Device DesignThe four screws that secure the patient table top to the carrier pulled out and caused the table top to detach. This issue may affect NeuViz Dual and NeuViz 16 scanners.
Feb 10, 2010Not classifiedZ-0846-2011OtherPotential for the CT patient table top to become detached from the carrier due to missing washers.
Jul 21, 2008Not classifiedZ-2237-2010Software designThe reference lines for image generated for a Surview scan may appear in the incorrect position in the "FILM" display mode.
Jun 23, 2008Not classifiedZ-2307-2008Nonconforming Material/ComponentPotential for R-host box and components inside to be detached of its mounting during the gantry rotor rotation. There is a potential for components to be damaged inside the system gantry and for the internal components to be expelled from…
Apr 10, 2008Not classifiedZ-0001-2009Software designAn issue associated with the "Timed Scan" application was found. The system does not wait for the programmed time interval and starts the x-ray after selection of the scan button when certain criteria is met.
Dec 17, 2007Not classifiedZ-2235-2008Software designLabeling of patient position on scanned image does not match actual patient orientation.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 4 companies; a new generation was cleared every 3.0 years on median.
  • 5 of the 13 ancestors have a recall of any class.
  • Of its descendants, K080540 (Neusoft Medical Systems Co., Ltd., 2008) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The NeuViz Dual Systems (modified) are intended to produce cross-section images of head

and body by computer reconstruction of X-ray transmission data taken at different angles.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K071308: Modification to Neuviz Dual Multi-Slice CT Scanner System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K071308

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026