510(k) Report

510(k) · Cleared

Recalled · Class I · 2019

Stellar 150

K122715510(k) TraditionalCleared Jun 17, 2013285-day reviewClass II21 CFR 868.5895Recalls 1 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Resmed Germany, Inc. · MNT Continuous, Minimal Ventilatory Support, Facility Use Ventilator

Cleared on Jun 17, 2013 as substantially equivalent to K113640 (Resmed Germany, Inc., 2012) and 1 other predicate after a 285-day review. Its family tree reaches back 10 generations to 1991. 9 of the 104 devices in its family, counting itself, have a Class I recall. It has been recalled once, including a Class I recall.

Decided
Jun 17, 2013
Review
285 days
Class
Class II
Product code
MNT
Recalls
1 (1 Class I)
Predicates
2

Its longest line of descent runs back 10 generations to K902859 (1991). 103 ancestors in all, the oldest K841279 (1984). No later device cites it as a predicate yet. 9 of the 104 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year cleared 2012: 1 other ancestor2011: 1 other ancestor2010: 2 other ancestors, 2 with a Class I recall22009: 2 other ancestors, 1 with a Class I recall12007: 1 other ancestor2006: 3 other ancestors2005: 1 other ancestor2003: 6 other ancestors, 1 with a Class I recall12000: 5 other ancestors1999: 5 other ancestors2008: 1 other ancestor2004: 5 other ancestors2002: 5 other ancestors2001: 10 other ancestors1998: 13 other ancestors, 2 with a Class I recall21984: 2 other ancestors1997: 4 other ancestors1996: 4 other ancestors1990: 4 other ancestors1994: 7 other ancestors1993: 1 other ancestor1991: 4 other ancestors1995: 3 other ancestors1992: 2 other ancestors1988: 1 other ancestorK902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 1999K013642 · AVEA · Bird Products Corp. · 2002 · Class I recallK032451 · Bird Tbird Vela Ventilator · Bird Products Corp. · 2004 · recalled×2: 2 generations cleared close together, K052554 (2005), K053270 (2006) K061627 · Modification to I Vent 201 · Versamed Medical Systems, Inc. · 2006K111610 · Trilogy Series Ventilator with Oximetry · Respironics, Inc. · 2011 · Class I recall19801985199019952000200520102015
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 4 other ancestors, 3 with a Class I recall33 generations back: 8 other ancestors4 generations back: 14 other ancestors, 1 with a Class I recall15 generations back: 19 other ancestors, 1 with a Class I recall16 generations back: 25 other ancestors, 1 with a Class I recall17 generations back: 16 other ancestors8 generations back: 5 other ancestors9 generations back: 1 other ancestor K111610 · Trilogy Series Ventilator with Oximetry · Respironics, Inc. · 2011 · Class I recallK061627 · Modification to I Vent 201 · Versamed Medical Systems, Inc. · 2006K053270 · IVENT 201 · Versamed Medical Systems, Inc. · 2006K052554 · Modification to: Ivent 201 Portable Ventilator · Versamed Medical Systems, Inc. · 2005K032451 · Bird Tbird Vela Ventilator · Bird Products Corp. · 2004 · recalledK013642 · AVEA · Bird Products Corp. · 2002 · Class I recallK992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 1999K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalled−10−50
  1. Root · 10 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 6 generations between
  3. 3 generations backK053270 IVENT 201Versamed Medical Systems, Inc. · 2006
  4. 2 generations backK061627 Modification to I Vent 201Versamed Medical Systems, Inc. · 2006
  5. 1 generation backK111610 Trilogy Series Ventilator with OximetryRespironics, Inc. · 2011 · Recalled (Class I)
  6. This deviceK122715 Stellar 150Resmed Germany, Inc. · 2013
Show all 10 generations
  1. Root · 10 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 9 generations backK960010 Servo Ventilator 300 Computer InterfaceSiemens Elema AB · 1996
  3. 8 generations backK970839 Servo Ventilator 300ASiemens Elema AB · 1997 · Recalled
  4. 7 generations backK992788 Bear Cub 750 PSVBear Medical Systems, Inc. · 1999
  5. 6 generations backK013642 AVEABird Products Corp. · 2002 · Recalled (Class I)
  6. 5 generations backK032451 Bird Tbird Vela VentilatorBird Products Corp. · 2004 · Recalled
  7. 4 generations backK052554 Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005
  8. 3 generations backK053270 IVENT 201Versamed Medical Systems, Inc. · 2006
  9. 2 generations backK061627 Modification to I Vent 201Versamed Medical Systems, Inc. · 2006
  10. 1 generation backK111610 Trilogy Series Ventilator with OximetryRespironics, Inc. · 2011 · Recalled (Class I)
  11. This deviceK122715 Stellar 150Resmed Germany, Inc. · 2013

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K902859Servo Ventilator 300Siemens Life Support Systems19913
−9K960010Servo Ventilator 300 Computer InterfaceSiemens Elema AB1996—
−8K970839Servo Ventilator 300ASiemens Elema AB19974
−7K992788Bear Cub 750 PSVBear Medical Systems, Inc.1999—
−6K013642AVEABird Products Corp.2002Class I
−5K032451Bird Tbird Vela VentilatorBird Products Corp.20041
−4K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2005—
−3K053270IVENT 201Versamed Medical Systems, Inc.2006—
−2K061627Modification to I Vent 201Versamed Medical Systems, Inc.2006—
−1K111610Trilogy Series Ventilator with OximetryRespironics, Inc.2011Class I
0 (this device)K122715Stellar 150Resmed Germany, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198420
198810
199040
199140
199220
199310
199470
199530
199640
199740
1998132
199950
200050
2001100
200250
200361
200450
200510
200630
200710
200810
200921
201022
201110
201210
FIG. 1 — Lineage of K122715, 1991–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

9 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MNT device

  1. #1 K233643 F&P Airvo 3 NIV (PT311US)score 13.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K113640Stellar 150
Summary page 1
…ax: +1858-836-5522 Stellar 150 Continuous ventilator 21 CFR 868.5895 - Product code MNT Ventilator, continuous, minimal ventilatory support, facility use Stellar 150 (K113640) Respironics Trilogy series Remote Alarm (K111610) New Remote Alarm accessory August 31, 2012 Stellar 150 510[k] Page 24 ===…
Resmed Germany, Inc.2012—
*K111610Trilogy Series Ventilator with Oximetry
Summary page 1
…tor 21 CFR 868.5895 - Product code MNT Ventilator, continuous, minimal ventilatory support, facility use Stellar 150 (K113640) Respironics Trilogy series Remote Alarm (K111610) New Remote Alarm accessory August 31, 2012 Stellar 150 510[k] Page 24 RESMED Stellar 150 Traditional 510(k) P…
Respironics, Inc.2011Class I

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (9 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 12, 2019Class IZ-0915-2020Device DesignCombination of software and a component failure may cause audible alarms not to operate properly, the alarm buzzer not work, for ventilators that have a failed electronic component and, that are stored without AC power connected for more…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K111610Trilogy Series Ventilator with OximetryRespironics, Inc. · 2011 · Direct predicate · ◆ on the line of descent in FIG. 12 Class I recalls
  • K093905Trilogy 202 VentilatorRespironics, Inc. · 2010 · 2 generations back · ◆ in the 2010 ancestors bar of FIG. 12 Class I recalls
  • K093416Trilogy 200 VentilatorRespironics, Inc. · 2010 · 2 generations back · ◆ in the 2010 ancestors bar of FIG. 14 Class I recalls
  • K083526Trilogy 100 VentilatorRespironics Inc., Sleep & Home Respiratory Group · 2009 · 2 generations back · ◆ in the 2009 ancestors bar of FIG. 15 Class I recalls
  • K981072Esprit VentilatorRespironics, Inc. · 1998 · 4 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K023366Datex-Ohmeda 7900 Ventilator EnhancementsDatex-Ohmeda, Inc. · 2003 · 5 generations back · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall
  • K013642AVEABird Products Corp. · 2002 · 5 generations back · ◆ on the line of descent in FIG. 113 Class I recalls
  • K970460Nellcor Puritan Bennett, 840 Ventilator System (Model 840)Puritan Bennett Corp. · 1998 · 6 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 22 years and passes through 7 companies; a new generation was cleared every 1.8 years on median.
  • 31 of the 103 ancestors have a recall of any class; 8 have a Class I recall.

How does its category compare?

All MNT devices

MNT Continuous, Minimal Ventilatory Support, Facility Use Ventilator: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · MNT

1in 2025

2008: 12009: 22011: 22012: 22013: 12017: 12020: 12022: 12023: 12024: 22025: 12026 (partial year): 1
2007high 2 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MNT

Too few MNT 510(k)s in any year since 2007 to give a median.

Recalls per year · MNT

5in 2022

2007: 12009: 12010: 12019: 1, 1 Class I2020: 332022: 5, 5 Class I
2007high 33 (2020) · low 0 (2008)2026

Class I (6 since 2007) Class II/III not classified

Adverse event reports per year · MNT

3,545in 2025

2007: 592008: 762009: 292010: 632011: 1702012: 2572013: 3222014: 8872015: 1,6572016: 2,5152017: 2,8782018: 2,2032019: 9,3502020: 4,1702021: 3,7902022: 3,2772023: 4,5652024: 4,8082025: 3,545
2007high 9,350 (2019) · low 29 (2009)2025

MAUDE reports naming product code MNT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—159
20081—076
20092—129
20100—163
20112—0170
20122—0257
20131—0322
20140—0887
20150—01,657
20160—02,515
20171—02,878
20180—02,203
20190—1 (1)9,350
20201—334,170
20210—03,790
20221—5 (5)3,277
20231—04,565
20242—04,808
20251—03,545
20261—0—

What is it indicated for?

The device is intended to provide ventilation for non-dependent, spontaneously breathing adult and pediatric patients (30 lb / 13 kg and above) with respiratory insufficiency or respiratory failure, with or without obstructive sleep apnea. The device is for non-invasive use, or invasive use (with the use of the ResMed Leak Valve). Operation of the device includes both stationary, such as in hospital or home, or mobile, such as wheelchair usage.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K122715: Stellar 150.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122715

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026