510(k) Report

510(k) · Cleared

Recalled · Class II · 2025

RayStation

K190387510(k) TraditionalCleared Jun 19, 2019120-day reviewClass II21 CFR 892.5050Recalls 32

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

RaySearch Laboratories AB (PUBL) · MUJ System, Planning, Radiation Therapy Treatment

Cleared on Jun 19, 2019 as substantially equivalent to K180379 (RaySearch Laboratories AB (PUBL), 2018) after a 120-day review. Its family tree reaches back 14 generations to 2001. 11 later devices descend from it. It has been recalled 32 times.

Decided
Jun 19, 2019
Review
120 days
Class
Class II
Product code
MUJ
Recalls
32
Predicates
1

Its longest line of descent runs back 14 generations to K010975 (2001). 69 ancestors in all, the oldest K802809 (1981). 11 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2013: 1 other ancestor2012: 1 other ancestor2009: 2 other ancestors2002: 3 other ancestors2000: 5 other ancestors2011: 1 other ancestor2010: 1 other ancestor2008: 3 other ancestors2007: 1 other ancestor2003: 2 other ancestors2001: 5 other ancestors1999: 4 other ancestors1997: 2 other ancestors1996: 5 other ancestors2006: 2 other ancestors2005: 1 other ancestor2004: 2 other ancestors1992: 4 other ancestors1991: 1 other ancestor1994: 2 other ancestors1990: 2 other ancestors1989: 2 other ancestors1987: 1 other ancestor1986: 1 other ancestor1981: 1 other ancestor2020: 1 descendant cleared2021: 3 descendants cleared2022: 2 descendants cleared2023: 2 descendants cleared2026: 1 descendant cleared2025: 2 descendants clearedK010975 · Eclipse 6.5 · Varian Medical Systems, Inc. · 2001 · recalledK030981 · Eclipse · Varian Medical Systems, Inc. · 2003K041403 · Eclipse with Aaa · Varian Medical Systems · 2004K050296 · Eclipse Treatment Planning System · Varian Medical Systems · 2005×2: 2 generations cleared close together, K071873 (2007), K073020 (2007) K091492 · Modification to Eclipse Treatment Planning System · Varian Medical Systems, Inc. · 2009 · recalledK102216 · Xio RTP System · Computerized Medical Systems, Inc. · 2010 · recalled×2: 2 generations cleared close together, K140187 (2014), K141860 (2014) K160093 · RayStation · RaySearch Laboratories AB (PUBL) · 2016 · recalled×2: 2 generations cleared close together, K170355 (2017), K171536 (2017) K180379 · RayStation 7 · RaySearch Laboratories AB (PUBL) · 2018 · recalled19801990200020102020
Other ancestors, by generationDescendants, by generation 7 generations back: 1 other ancestor8 generations back: 4 other ancestors9 generations back: 7 other ancestors10 generations back: 11 other ancestors11 generations back: 14 other ancestors12 generations back: 14 other ancestors13 generations back: 4 other ancestors 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 2 descendants4 generations forward: 2 descendants5 generations forward: 1 descendant6 generations forward: 1 descendant7 generations forward: 1 descendant K180379 · RayStation 7 · RaySearch Laboratories AB (PUBL) · 2018 · recalledK171536 · RayStation · RaySearch Laboratories AB (PUBL) · 2017 · recalledK170355 · RayStation 6 · RaySearch Laboratories AB (PUBL) · 2017 · recalledK160093 · RayStation · RaySearch Laboratories AB (PUBL) · 2016 · recalledK141860 · Raystation · Raysearch Laboratories AB · 2014 · recalledK140187 · Ray Station · Raysearch Laboratories AB · 2014 · recalledK102216 · Xio RTP System · Computerized Medical Systems, Inc. · 2010 · recalledK091492 · Modification to Eclipse Treatment Planning System · Varian Medical Systems, Inc. · 2009 · recalledK073020 · Eclipse Treatment Planning System · Varian Medical Systems, Inc. · 2007 · recalledK071873 · Modification to Eclipse Treatment Planning System · Varian Medical Systems, Inc. · 2007 · recalledK050296 · Eclipse Treatment Planning System · Varian Medical Systems · 2005K041403 · Eclipse with Aaa · Varian Medical Systems · 2004K030981 · Eclipse · Varian Medical Systems, Inc. · 2003K010975 · Eclipse 6.5 · Varian Medical Systems, Inc. · 2001 · recalled−10−50+5
  1. Root · 14 generations backK010975 Eclipse 6.5Varian Medical Systems, Inc. · 2001 · Recalled
  2. 10 generations between
  3. 3 generations backK170355 RayStation 6RaySearch Laboratories AB (PUBL) · 2017 · Recalled
  4. 2 generations backK171536 RayStationRaySearch Laboratories AB (PUBL) · 2017 · Recalled
  5. 1 generation backK180379 RayStation 7RaySearch Laboratories AB (PUBL) · 2018 · Recalled
  6. This deviceK190387 RayStationRaySearch Laboratories AB (PUBL) · 2019
  7. Descendant · cites it directly · 6 of its ownK200569 RayStationRaySearch Laboratories AB (PUBL) · 2020 · Recalled
  8. Descendant · 2 generations on · 5 of its ownK210645 RayStation 10.1RaySearch Laboratories AB (PUBL) · 2021 · Recalled
  9. Descendant · 3 generations on · 4 of its ownK211867 RayStation 11.0RaySearch Laboratories AB (PUBL) · 2021 · Recalled
  10. Descendant · 4 generations on · 3 of its ownK220141 RayStation 11BRaySearch Laboratories AB (PUBL) · 2022 · Recalled
  11. Descendant · cites it directly · 3 of its ownK202789 Monaco Rtp SystemElekta Solutions AB · 2021
Show all 14 generations
  1. Root · 14 generations backK010975 Eclipse 6.5Varian Medical Systems, Inc. · 2001 · Recalled
  2. 13 generations backK030981 EclipseVarian Medical Systems, Inc. · 2003
  3. 12 generations backK041403 Eclipse with AaaVarian Medical Systems · 2004
  4. 11 generations backK050296 Eclipse Treatment Planning SystemVarian Medical Systems · 2005
  5. 10 generations backK071873 Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc. · 2007 · Recalled
  6. 9 generations backK073020 Eclipse Treatment Planning SystemVarian Medical Systems, Inc. · 2007 · Recalled
  7. 8 generations backK091492 Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc. · 2009 · Recalled
  8. 7 generations backK102216 Xio RTP SystemComputerized Medical Systems, Inc. · 2010 · Recalled
  9. 6 generations backK140187 Ray StationRaysearch Laboratories AB · 2014 · Recalled
  10. 5 generations backK141860 RaystationRaysearch Laboratories AB · 2014 · Recalled
  11. 4 generations backK160093 RayStationRaySearch Laboratories AB (PUBL) · 2016 · Recalled
  12. 3 generations backK170355 RayStation 6RaySearch Laboratories AB (PUBL) · 2017 · Recalled
  13. 2 generations backK171536 RayStationRaySearch Laboratories AB (PUBL) · 2017 · Recalled
  14. 1 generation backK180379 RayStation 7RaySearch Laboratories AB (PUBL) · 2018 · Recalled
  15. This deviceK190387 RayStationRaySearch Laboratories AB (PUBL) · 2019

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

2020: 12021: 32022: 22023: 22025: 22026: 1
2020high 3 (2021) · low 0 (2024)2026

Most influential descendants

Showing 5 of 11 · See all
  • K200569RayStationRaySearch Laboratories AB (PUBL) · 2020 · cites it directly6descendants
  • K210645RayStation 10.1RaySearch Laboratories AB (PUBL) · 2021 · 2 generations on5descendants
  • K211867RayStation 11.0RaySearch Laboratories AB (PUBL) · 2021 · 3 generations on4descendants
  • K220141RayStation 11BRaySearch Laboratories AB (PUBL) · 2022 · 4 generations on3descendants
  • K202789Monaco Rtp SystemElekta Solutions AB · 2021 · cites it directly3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K010975Eclipse 6.5Varian Medical Systems, Inc.20013
−13K030981EclipseVarian Medical Systems, Inc.2003—
−12K041403Eclipse with AaaVarian Medical Systems2004—
−11K050296Eclipse Treatment Planning SystemVarian Medical Systems2005—
−10K071873Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc.20075
−9K073020Eclipse Treatment Planning SystemVarian Medical Systems, Inc.20076
−8K091492Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc.20092
−7K102216Xio RTP SystemComputerized Medical Systems, Inc.20107
−6K140187Ray StationRaysearch Laboratories AB20141
−5K141860RaystationRaysearch Laboratories AB20145
−4K160093RayStationRaySearch Laboratories AB (PUBL)20167
−3K170355RayStation 6RaySearch Laboratories AB (PUBL)20171
−2K171536RayStationRaySearch Laboratories AB (PUBL)20176
−1K180379RayStation 7RaySearch Laboratories AB (PUBL)20187
0 (this device)K190387RayStationRaySearch Laboratories AB (PUBL)2019—
+1K200569RayStationRaySearch Laboratories AB (PUBL)202014
+2K210645RayStation 10.1RaySearch Laboratories AB (PUBL)20216
+3K211867RayStation 11.0RaySearch Laboratories AB (PUBL)20218
+4K220141RayStation 11BRaySearch Laboratories AB (PUBL)20226
+1K202789Monaco Rtp SystemElekta Solutions AB2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198610
198710
198920
199020
199110
199240
199420
199650
199720
199940
200050
200150
200230
200320
200420
200510
200620
200710
200830
200920
201010
201110
201210
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
202130
202220
202320
202520
202610
FIG. 1 — Lineage of K190387, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUJ device

  1. #1 K232799 syngo.via RT Image Suitescore 18.6 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K180379RayStation 7
Summary page 4
…assification name Medical charged-particle radiation therapy system (21 CFR 892.5050, Product Code MUJ) 5.7 Predicate device RayStation 7.0 K180379 5.8 Device description RayStation 8.1 is a radiation therapy treatment planning system, i.e. a software program for pla…
RaySearch Laboratories AB (PUBL)20187

What descends from it? (11)

See all 11

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K200569RayStationRaySearch Laboratories AB (PUBL)20206
K202789Monaco Rtp SystemElekta Solutions AB20213

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 8, 2025Class IIZ-2488-2025Under Investigation by firmDICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique.
Jan 16, 2025Class IIZ-1186-2025Under Investigation by firmInconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in…
Mar 28, 2024Class IIZ-1744-2024Software designPotential for reported SSD to be too high.
Mar 28, 2024Class IIZ-1743-2024Software designPotential for reported SSD to be too high.
Feb 23, 2024Class IIZ-1482-2024Under Investigation by firmA use error that has occurred with RayStation/RayPlan, where material override using Silicon, Si, was incorrectly selected for a silicone gel polymer implant.
Feb 17, 2023Class IIZ-1281-2023Under Investigation by firmIt is possible to set a non-zero collimator angle in the Virtual Simulation module. The angle will be correct in the user interface but if the plan is DICOM exported by using the VSIM Export button, the angle will not be correct in the…
May 26, 2020Class IIZ-2426-2020Under Investigation by firmIt is not obvious that the manual import of a treatment record into RayCare PACS does not automatically import the same data into RayTreat. In addition, there is an issue found with the display of planned and recorded Gantry Angle in the…
May 18, 2020Class IIZ-2343-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2351-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2341-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2352-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2342-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2344-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2348-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2349-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2340-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2350-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2353-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2347-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2346-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2339-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
May 18, 2020Class IIZ-2345-2020Software designSoftware error was identified in the Pencil Beam Scanning (PBS) and Line Scanning (LS) dose calculation algorithms that could result in a local underestimation of expected dose.
Mar 4, 2020Class IIZ-1598-2020Under Investigation by firmDue to physical limitations of the treatment machine, the maximum field opening for Siemens Virtual Wedge fields recommended by the LINAC vendor will be more restricted in the wedged direction than the maximum field opening without a…
Feb 20, 2020Class IIZ-1462-2020Under Investigation by firmThere is a potential for erroneous propagation of the current tabletop positions when applying pitch or roll correction. Even though pitch and roll correction is never propagated, non-zero pitch or roll causes the lateral, longitudinal…
Feb 20, 2020Class IIZ-1468-2020Under Investigation by firmThere is a potential for erroneous propagation of the current tabletop positions when applying pitch or roll correction. Even though pitch and roll correction is never propagated, non-zero pitch or roll causes the lateral, longitudinal…
Feb 20, 2020Class IIZ-1467-2020Under Investigation by firmThere is a potential for erroneous propagation of the current tabletop positions when applying pitch or roll correction. Even though pitch and roll correction is never propagated, non-zero pitch or roll causes the lateral, longitudinal…
Feb 20, 2020Class IIZ-1463-2020Under Investigation by firmThere is a potential for erroneous propagation of the current tabletop positions when applying pitch or roll correction. Even though pitch and roll correction is never propagated, non-zero pitch or roll causes the lateral, longitudinal…
Feb 20, 2020Class IIZ-1465-2020Under Investigation by firmThere is a potential for erroneous propagation of the current tabletop positions when applying pitch or roll correction. Even though pitch and roll correction is never propagated, non-zero pitch or roll causes the lateral, longitudinal…
Feb 20, 2020Class IIZ-1466-2020Under Investigation by firmThere is a potential for erroneous propagation of the current tabletop positions when applying pitch or roll correction. Even though pitch and roll correction is never propagated, non-zero pitch or roll causes the lateral, longitudinal…
Feb 20, 2020Class IIZ-1464-2020Under Investigation by firmThere is a potential for erroneous propagation of the current tabletop positions when applying pitch or roll correction. Even though pitch and roll correction is never propagated, non-zero pitch or roll causes the lateral, longitudinal…
Dec 19, 2019Class IIZ-0866-2020Software designThree issues found: i) The Map ROI options in the ROI list in the Structure Definition module may generate unintended ROI geometries ii) Elekta guard leaf behavior. There is an interoperability issue with Elekta regarding setting of guard…
Nov 18, 2019Class IIZ-0736-2020Software designEditing a static arc beam may unexpectedly set the MU of the beam to its initial default value of 200 MU. If the bug is triggered, the dose is invalidated and needs to be recalculated before the plan can be approved or exported.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 1.3 years on median.
  • 24 of the 69 ancestors have a recall of any class.
  • Of its descendants, K200569 (RaySearch Laboratories AB (PUBL), 2020) has gone furthest, with 6 descendants of its own.

How does its category compare?

All MUJ devices

MUJ System, Planning, Radiation Therapy Treatment: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · MUJ

10in 2025

2007: 42008: 92009: 162010: 112011: 92012: 82013: 52014: 92015: 132016: 52017: 72018: 72019: 92020: 92021: 112022: 82023: 102024: 92025: 102026 (partial year): 9
2007high 16 (2009) · low 4 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUJ

186in 2025

2007: 67 days median2008: 63 days median2009: 84 days median2010: 56 days median2011: 103 days median2012: 59 days median2013: 64 days median2014: 108 days median2015: 78 days median2016: 80 days median2017: 30 days median2018: 53 days median2019: 56 days median2020: 104 days median2021: 87 days median2022: 168 days median2023: 140 days median2024: 122 days median2025: 186 days median2026 (partial year): 233 days median
2007high 233 (2026) · low 30 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUJ

2in 2023

2007: 42008: 102009: 112010: 232011: 172012: 42013: 62014: 22015: 72016: 132017: 42018: 32019: 42020: 22021: 42022: 32023: 22026 (partial year): 2
2007high 23 (2010) · low 0 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUJ

21in 2025

2007: 242008: 512009: 242010: 782011: 732012: 392013: 332014: 352015: 302016: 272017: 162018: 252019: 252020: 262021: 152022: 222023: 762024: 92025: 21
2007high 78 (2010) · low 9 (2024)2025

MAUDE reports naming product code MUJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007467424
20089631051
200916841124
201011562378
201191031773
2012859439
2013564633
20149108235
20151378730
20165801327
2017730416
2018753325
2019956425
20209104226
20211187415
20228168322
202310140276
2024912209
202510186021
202692332—

What is it indicated for?

RayStation is a software system designed for treatment planning and analysis of radiation therapy. The treatment plans provide treatment unit set-up parameters and estimates of dose distributions expected during the proposed treatment, and may be used to administer treatments after review and approval by the intended user.

The system functionality can be configured based on user needs.

The intended users of RayStation shall be clinically qualified radiation therapy staff trained in using the system.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K190387: RayStation.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K190387

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026