510(k) Report

510(k) · Cleared

Cleared

The Multimodality Advanced Vessel Analysis

K203216510(k) TraditionalCleared Nov 25, 202023-day reviewClass II21 CFR 892.1750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems Nederland B.V. · JAK System, X-Ray, Tomography, Computed

Cleared on Nov 25, 2020 as substantially equivalent to K060937 (Philips Medical Systems (Cleveland), Inc., 2006) and 2 other predicates after a 23-day review. Its family tree reaches back 11 generations to 1997. 3 of the 125 devices in its family, counting itself, have a Class I recall. 1 later device descends from it.

Decided
Nov 25, 2020
Review
23 days
Class
Class II
Product code
JAK
Recalls
None
Predicates
3

Its longest line of descent runs back 11 generations to K971684 (1997). 123 ancestors in all, the oldest K837107 (1983). 1 later device descends from it, 1 citing it directly. 3 of the 125 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2011: 3 other ancestors2006: 8 other ancestors2012: 1 other ancestor2009: 4 other ancestors2005: 8 other ancestors2003: 6 other ancestors2008: 3 other ancestors2007: 4 other ancestors2004: 7 other ancestors2002: 6 other ancestors2001: 14 other ancestors1983: 1 other ancestor2010: 1 other ancestor2000: 7 other ancestors1999: 4 other ancestors1998: 8 other ancestors1997: 6 other ancestors1996: 6 other ancestors1995: 3 other ancestors1994: 5 other ancestors1991: 2 other ancestors1993: 2 other ancestors1987: 1 other ancestor1988: 2 other ancestors2026: 1 descendant clearedK971684 · Magnetom Project 047 System (Numaris 3.5 Software) · Siemens Medical Solutions USA, Inc. · 1997 · recalledK032428 · Magnetom Avanto MR System · Siemens Medical Solutions USA, Inc. · 2003 · recalledK041112 · Magnetom Espree System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK052164 · Magnetom Systems with Software Syngo MR 2006A · Siemens Medical Solutions USA, Inc. · 2005K062454 · Magnetom Systems - I-Class and T-Class Releases · Siemens Medi Cal Solutions, Inc. · 2006K072237 · Magnetom Verio · Siemens Medical Solutions USA, Inc. · 2007 · Class I recallK082427 · Syngo MR B17 · Siemens Medical Solutions USA, Inc. · 2008K101347 · Magnetom Aera; Magnetom Skyra · Siemens Medical Solutions USA, Inc. · 2010 · Class I recallK111242 · Magnetom Aera and Magnetom Skyra · Siemens Medical Solutions USA, Inc. · 2011 · recalledK121434 · Software Syngo MR D13A for the Magnetom Systems Aera/Skyra/Avanto/Verio · Siemens Medi Cal Solutions, Inc. · 2012 · Class I recallK130749 · Syngo.MR General; Syngo.MR Cardiology; Syngo.MR Vascular · Siemens Medical Solutions USA, Inc. · 201319801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 6 other ancestors3 generations back: 14 other ancestors4 generations back: 28 other ancestors5 generations back: 28 other ancestors6 generations back: 24 other ancestors7 generations back: 7 other ancestors8 generations back: 3 other ancestors 1 generation forward: 1 descendant K130749 · Syngo.MR General; Syngo.MR Cardiology; Syngo.MR Vascular · Siemens Medical Solutions USA, Inc. · 2013K121434 · Software Syngo MR D13A for the Magnetom Systems Aera/Skyra/Avanto/Verio · Siemens Medi Cal Solutions, Inc. · 2012 · Class I recallK111242 · Magnetom Aera and Magnetom Skyra · Siemens Medical Solutions USA, Inc. · 2011 · recalledK101347 · Magnetom Aera; Magnetom Skyra · Siemens Medical Solutions USA, Inc. · 2010 · Class I recallK082427 · Syngo MR B17 · Siemens Medical Solutions USA, Inc. · 2008K072237 · Magnetom Verio · Siemens Medical Solutions USA, Inc. · 2007 · Class I recallK062454 · Magnetom Systems - I-Class and T-Class Releases · Siemens Medi Cal Solutions, Inc. · 2006K052164 · Magnetom Systems with Software Syngo MR 2006A · Siemens Medical Solutions USA, Inc. · 2005K041112 · Magnetom Espree System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK032428 · Magnetom Avanto MR System · Siemens Medical Solutions USA, Inc. · 2003 · recalledK971684 · Magnetom Project 047 System (Numaris 3.5 Software) · Siemens Medical Solutions USA, Inc. · 1997 · recalled−10−50
  1. Root · 11 generations backK971684 Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc. · 1997 · Recalled
  2. 7 generations between
  3. 3 generations backK111242 Magnetom Aera and Magnetom SkyraSiemens Medical Solutions USA, Inc. · 2011 · Recalled
  4. 2 generations backK121434 Software Syngo MR D13A for the Magnetom Systems…Siemens Medi Cal Solutions, Inc. · 2012 · Recalled (Class I)
  5. 1 generation backK130749 Syngo.MR General; Syngo.MR Cardiology; Syngo.MR VascularSiemens Medical Solutions USA, Inc. · 2013
  6. This deviceK203216 The Multimodality Advanced Vessel AnalysisPhilips Medical Systems Nederland B.V. · 2020
  7. Descendant · cites it directly · 0 of its ownK253735 AV VascularPhilips Medical Systems Nederland B.V. · 2026
Show all 11 generations
  1. Root · 11 generations backK971684 Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc. · 1997 · Recalled
  2. 10 generations backK032428 Magnetom Avanto MR SystemSiemens Medical Solutions USA, Inc. · 2003 · Recalled
  3. 9 generations backK041112 Magnetom Espree SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
  4. 8 generations backK052164 Magnetom Systems with Software Syngo MR 2006ASiemens Medical Solutions USA, Inc. · 2005
  5. 7 generations backK062454 Magnetom Systems - I-Class and T-Class ReleasesSiemens Medi Cal Solutions, Inc. · 2006
  6. 6 generations backK072237 Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · Recalled (Class I)
  7. 5 generations backK082427 Syngo MR B17Siemens Medical Solutions USA, Inc. · 2008
  8. 4 generations backK101347 Magnetom Aera; Magnetom SkyraSiemens Medical Solutions USA, Inc. · 2010 · Recalled (Class I)
  9. 3 generations backK111242 Magnetom Aera and Magnetom SkyraSiemens Medical Solutions USA, Inc. · 2011 · Recalled
  10. 2 generations backK121434 Software Syngo MR D13A for the Magnetom Systems…Siemens Medi Cal Solutions, Inc. · 2012 · Recalled (Class I)
  11. 1 generation backK130749 Syngo.MR General; Syngo.MR Cardiology; Syngo.MR VascularSiemens Medical Solutions USA, Inc. · 2013
  12. This deviceK203216 The Multimodality Advanced Vessel AnalysisPhilips Medical Systems Nederland B.V. · 2020

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K253735AV VascularPhilips Medical Systems Nederland B.V. · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K971684Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc.19974
−10K032428Magnetom Avanto MR SystemSiemens Medical Solutions USA, Inc.20034
−9K041112Magnetom Espree SystemSiemens Medical Solutions USA, Inc.20044
−8K052164Magnetom Systems with Software Syngo MR 2006ASiemens Medical Solutions USA, Inc.2005—
−7K062454Magnetom Systems - I-Class and T-Class ReleasesSiemens Medi Cal Solutions, Inc.2006—
−6K072237Magnetom VerioSiemens Medical Solutions USA, Inc.2007Class I
−5K082427Syngo MR B17Siemens Medical Solutions USA, Inc.2008—
−4K101347Magnetom Aera; Magnetom SkyraSiemens Medical Solutions USA, Inc.2010Class I
−3K111242Magnetom Aera and Magnetom SkyraSiemens Medical Solutions USA, Inc.20113
−2K121434Software Syngo MR D13A for the Magnetom Systems Aera/Skyra/Avanto/VerioSiemens Medi Cal Solutions, Inc.2012Class I
−1K130749Syngo.MR General; Syngo.MR Cardiology; Syngo.MR VascularSiemens Medical Solutions USA, Inc.2013—
0 (this device)K203216The Multimodality Advanced Vessel AnalysisPhilips Medical Systems Nederland B.V.2020—
+1K253735AV VascularPhilips Medical Systems Nederland B.V.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198310
198710
198820
199120
199320
199450
199530
199660
199760
199880
199940
200070
2001140
200260
200360
200470
200580
200680
200740
200830
200940
201010
201130
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202610
FIG. 1 — Lineage of K203216, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K060937Brilliance Volume
Summary page 6
…Device Name Manufacturer 510k No Primary Predicate Brilliance Volume Philips Medical Systems (Cleveland), K060937 Inc. Secondary Predicate syngo.CT Vascular Siemens Medical Soluti…
Philips Medical Systems (Cleveland), Inc.200661
*K112020Syngo.CT Vascular Analysis
Summary page 6
…ems (Cleveland), K060937 Inc. Secondary Predicate syngo.CT Vascular Siemens Medical Solutions, Inc. K112020 Analysis Secondary Predicate syngo.MR Vascular Siemens Medical Solutions, Inc. K1307…
Siemens Medi Cal Solutions, Inc.2011—
*K130749Syngo.MR General; Syngo.MR Cardiology; Syngo.MR Vascular
Summary page 6
…Siemens Medical Solutions, Inc. K112020 Analysis Secondary Predicate syngo.MR Vascular Siemens Medical Solutions, Inc. K130749 The proposed Philips Medical Systems Multimodality Advanced Vessels Analysis (MM AVA) application and its predicate devices,…
Siemens Medical Solutions USA, Inc.2013—

Also cleared against K060937: 7 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K253735AV VascularPhilips Medical Systems Nederland B.V.20260

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K121434Software Syngo MR D13A for the Magnetom Systems Aera/Skyra/Avanto/VerioSiemens Medi Cal Solutions, Inc. · 2012 · 2 generations back · ◆ on the line of descent in FIG. 12 Class I recalls
  • K101347Magnetom Aera; Magnetom SkyraSiemens Medical Solutions USA, Inc. · 2010 · 4 generations back · ◆ on the line of descent in FIG. 12 Class I recalls
  • K072237Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · 4 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 23 years and passes through 3 companies; a new generation was cleared every 1.1 years on median.
  • 32 of the 123 ancestors have a recall of any class; 3 have a Class I recall.
  • Of its descendants, K253735 (Philips Medical Systems Nederland B.V., 2026) has gone furthest, with 0 descendants of its own.
  • 7 other devices also cite its predicate K060937.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The Multimodality Advanced Vessels Analysis (MM AVA) application is intended for visualization, assessment and quantification of vascular datasets.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K203216: The Multimodality Advanced Vessel Analysis.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K203216

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026