ClearedBrilliance Dual Energy Option
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Philips Medical Systems (Cleveland), Inc. · JAK System, X-Ray, Tomography, Computed
Cleared on Jun 23, 2009 as substantially equivalent to K060937 (Philips Medical Systems (Cleveland), Inc., 2006) and 1 other predicate after a 120-day review. Its family tree reaches back 6 generations to 1993. 3 later devices descend from it.
- Decided
- Jun 23, 2009
- Review
- 120 days
- Class
- Class II
- Product code
- JAK
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 6 generations to K930090 (1993). 16 ancestors in all. 3 later devices descend from it, 1 citing it directly.
- Root · 6 generations backK930090 HelicatElscint, Inc. · 1993
- 5 generations backK961464 Select/SPElscint, Inc. · 1996 · Recalled
- 4 generations backK982060 Volumax CT Imaging SystemElscint, Inc. · 1998
- 3 generations backK012009 MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · Recalled
- 2 generations backK033326 Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc. · 2003 · Recalled
- 1 generation backK060937 Brilliance VolumePhilips Medical Systems (Cleveland), Inc. · 2006 · Recalled
- This deviceK090462 Brilliance Dual Energy OptionPhilips Medical Systems (Cleveland), Inc. · 2009
- Descendant · cites it directly · 2 of its ownK093703 3DIShina Systems, Ltd. · 2010
- Descendant · 2 generations on · 1 of its ownK112530 3DI Including CscoreShina Systems, Ltd. · 2011
- Descendant · 3 generations on · 0 of its ownK113442 3DIShina Systems, Ltd. · 2012
Most influential descendants
Showing 3 of 3 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K930090 | Helicat | Elscint, Inc. | 1993 | — |
| −5 | K961464 | Select/SP | Elscint, Inc. | 1996 | 3 |
| −4 | K982060 | Volumax CT Imaging System | Elscint, Inc. | 1998 | — |
| −3 | K012009 | MX8000 Idt CT System | Marconi Medical Systems, Inc. | 2001 | 61 |
| −2 | K033326 | Philips Plus Computed Tomography System | Philips Medical Systems, Inc. | 2003 | 131 |
| −1 | K060937 | Brilliance Volume | Philips Medical Systems (Cleveland), Inc. | 2006 | 61 |
| 0 (this device) | K090462 | Brilliance Dual Energy Option | Philips Medical Systems (Cleveland), Inc. | 2009 | — |
| +1 | K093703 | 3DI | Shina Systems, Ltd. | 2010 | — |
| +2 | K112530 | 3DI Including Cscore | Shina Systems, Ltd. | 2011 | — |
| +3 | K113442 | 3DI | Shina Systems, Ltd. | 2012 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 2 | 0 |
| 1995 | 1 | 0 |
| 1997 | 1 | 0 |
| 2001 | 2 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2006 | 1 | 0 |
| 2008 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 1 | 0 |
| 2011 | 1 | 0 |
| 2012 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K060937 | Brilliance VolumeSummary page 1…y option is of comparable type and substantially equivalent to the legally marketed devices currently in commercial distribution, namely: the Philips Brilliance Volume - K060937 and the GE Lightspeed CT750 HD - K081105. 4. Device Description Philips Healthcare offers a Dual Energy scanning option on t… | 2006 |
| * | K081105 | GE Lightspeed CT750 HD (Lightspeed 8.0)Summary page 1…ntially equivalent to the legally marketed devices currently in commercial distribution, namely: the Philips Brilliance Volume - K060937 and the GE Lightspeed CT750 HD - K081105. 4. Device Description Philips Healthcare offers a Dual Energy scanning option on the Brilliance CT Scanner. The Brilliance… | 2008 |
What descends from it? (3)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K093703 | 3DI | 2010 | 2 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 3.0 years on median.
- 10 of the 16 ancestors have a recall of any class.
- Of its descendants, K093703 (Shina Systems, Ltd., 2010) has gone furthest, with 2 descendants of its own.
- 7 other devices also cite its predicate K060937.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
The Brilliance CT is a Computed Tomography X-Ray System intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes. This device may include signal analysis and display equipment, patient, and equipment supports, components and accessories. The dual energy option allows the system to acquire two CT images of the same anatomical location using two distinct tube voltages…
Read the full statement (153 words)
The Brilliance CT is a Computed Tomography X-Ray System intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes. This device may include signal analysis and display equipment, patient, and equipment supports, components and accessories.
The dual energy option allows the system to acquire two CT images of the same anatomical location using two distinct tube voltages and/or tube currents during two tube rotations. The x-ray dose will be the sum of the doses of each tube rotation at its respective tube voltage and current. Information regarding the material composition of various organs, tissues, and contrast materials may be gained from the differences in x-ray attenuation between these distinct energies. This information may also be used to reconstruct images at multiple energies within the available spectrum, and to reconstruct basis images that allow the visualization and analysis of anatomical and pathological materials.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K090462 · printed Nov 5, 2026
Cite this page
510(k) Report. “K090462: Brilliance Dual Energy Option.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K090462