510(k) Report

510(k) · Cleared

Cleared

Savina

K003068510(k) TraditionalCleared Jun 25, 2001266-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Drager Medizintechnik GmbH · CBK Ventilator, Continuous, Facility Use

Cleared on Jun 25, 2001 after a 266-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 42 of the 135 devices in its family, counting itself, have a Class I recall. 134 later devices descend from it.

Decided
Jun 25, 2001
Review
266 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
0

134 later devices descend from it, 5 citing it directly. 42 of the 135 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2014: 4 descendants cleared, 1 with a Class I recall12006: 6 descendants cleared, 2 with a Class I recall22002: 1 descendant cleared2003: 1 descendant cleared2004: 7 descendants cleared, 2 with a Class I recall22010: 5 descendants cleared, 1 with a Class I recall12008: 11 descendants cleared, 4 with a Class I recall42009: 4 descendants cleared, 1 with a Class I recall12011: 12 descendants cleared, 7 with a Class I recall72015: 7 descendants cleared, 2 with a Class I recall22012: 12 descendants cleared, 4 with a Class I recall42019: 7 descendants cleared, 2 with a Class I recall22005: 2 descendants cleared2007: 4 descendants cleared2016: 4 descendants cleared, 2 with a Class I recall22023: 5 descendants cleared, 1 with a Class I recall12021: 7 descendants cleared, 3 with a Class I recall32026: 5 descendants cleared2013: 8 descendants cleared, 4 with a Class I recall42017: 7 descendants cleared, 3 with a Class I recall32022: 1 descendant cleared2024: 4 descendants cleared2025: 5 descendants cleared2020: 4 descendants cleared, 3 with a Class I recall32018: 1 descendant cleared200020052010201520202025
  1. This deviceK003068 SavinaDrager Medizintechnik GmbH · 2001
  2. Descendant · cites it directly · 102 of its ownK022132 Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc. · 2002
  3. Descendant · 2 generations on · 75 of its ownK040221 Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · Recalled
  4. Descendant · 3 generations on · 73 of its ownK041223 Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · Recalled (Class I)
  5. Descendant · 4 generations on · 61 of its ownK063404 Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007
  6. Descendant · 2 generations on · 53 of its ownK040574 Galileo GoldHamilton Medical, Inc. · 2004

Showing 5 of 134 descendants. See all descendants

Descendants cleared per year

2002: 12003: 12004: 72005: 22006: 62007: 42008: 112009: 42010: 52011: 122012: 122013: 82014: 42015: 72016: 42017: 72018: 12019: 72020: 42021: 72022: 12023: 52024: 42025: 52026: 5
2002high 12 (2011) · low 1 (2002)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 134 · See all
  • K022132Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc. · 2002 · cites it directly102descendants
  • K040221Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · 2 generations on75descendants
  • K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · 3 generations on73descendants
  • K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007 · 4 generations on61descendants
  • K040574Galileo GoldHamilton Medical, Inc. · 2004 · 2 generations on53descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K003068SavinaDrager Medizintechnik GmbH2001—
+1K022132Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc.2002—
+2K040221Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB20041
+3K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB2004Class I
+4K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB2007—
+2K040574Galileo GoldHamilton Medical, Inc.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200472
200520
200662
200740
2008114
200941
201051
2011127
2012124
201384
201441
201572
201642
201773
201810
201972
202043
202173
202210
202351
202440
202550
202650
FIG. 1 — Lineage of K003068, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

42 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (134)

See all 134

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K022132Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc.2002102
K060705Carina HomeDraeger Medical B.V.200622
K062267Oxylog 3000 Class IDrager Medical B.V.200620
K023289Option Niv, Model 8414115, Upgrade Kit Niv, Model 8414072Drager Medizintechnik GmbH200317
K121886Savina 300 Savina 300, Country VariantsDraeger Medical GmbH20141

Has anything in its family been recalled? (42 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K062267Oxylog 3000Drager Medical B.V. · 2006 · Cites it directly · ◆ in the 2006 descendants bar of FIG. 13 Class I recalls
  • K034040Esprit Ventilator, Model V1000Respironics, Inc. · 2004 · 2 generations on · ◆ in the 2004 descendants bar of FIG. 11 Class I recall
  • K073069Modification to Avea VentilatorViasys Respiratory Care, Inc. · 2008 · 2 generations on · ◆ in the 2008 descendants bar of FIG. 113 Class I recalls
  • K072885Carina System, Model 8419350; Carina Basic Device, Model 5704110Draeger Medical AG & Co. KG · 2008 · 2 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
  • K082600Oxylog 2000 Plus System (Model 5705080), Oxylog 2000 Plus Basic Device (Model 5705082)Draeger Medical B.V. · 2008 · 2 generations on · ◆ in the 2008 descendants bar of FIG. 12 Class I recalls
  • K103625Oxylog 3000 Plus Workstation, Oxylog 3000 Plus Basic DeviceDraeger Medical Systems, Inc. · 2011 · 2 generations on · ◆ in the 2011 descendants bar of FIG. 14 Class I recalls
  • K141595O-Two E700,O-Two E600,O-Two E500O-Two Medical Technologies, Inc. · 2015 · 2 generations on · ◆ in the 2015 descendants bar of FIG. 13 Class I recalls
  • K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · 3 generations on · ◆ in the 2004 descendants bar of FIG. 11 Class I recall
  • K113053Bipap a 30 Ventilatory Support SystemRespironics, Inc. · 2012 · 3 generations on · ◆ in the 2012 descendants bar of FIG. 15 Class I recalls
  • K120670Hamilton-T1Hamilton Medical AG · 2012 · 3 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K181216Hamilton-T1, Hamilton-C1Hamilton Medical AG · 2019 · 3 generations on · ◆ in the 2019 descendants bar of FIG. 15 Class I recalls
  • K153046Hamilton-MR1Hamilton Medical AG · 2016 · 3 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall

Nearest 12 of 42 shown.

What does this lineage say?

  • Of its descendants, K022132 (Siemens Medical Solutions USA, Inc., 2002) has gone furthest, with 102 descendants of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—
Cite this page

510(k) Report. “K003068: Savina.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K003068

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026