Alaris PC Unit, Models 8000 and 8015

K091308510(k) TraditionalCleared Jul 9, 200966-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cardinal Health 303,Inc. · FRN Pump, Infusion

Cleared on Jul 9, 2009 as substantially equivalent to K051641 (Cardinal Health, Alaris Products, 2005) after a 66-day review. Its family tree reaches back 2 generations to 1995. 4 of the 8 devices in its family, counting itself, have a Class I recall. 5 later devices descend from it.

Decided
Jul 9, 2009
Review
66 days
Class
Class II
Product code
FRN
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K950419 (1995). 5 later devices descend from it, 2 citing it directly. 4 of the 8 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2012: 1 descendant cleared2014: 1 descendant cleared, 1 with a Class I recall12022: 1 descendant cleared2023: 1 descendant cleared, 1 with a Class I recall12025: 1 descendant clearedK950419 · The Imed Orion Infusion Pump and Administration Sets · Imed Corp. · 1995 · Class I recallK051641 · Alaris System PC Unit, Model 8001 · Cardinal Health, Alaris Products · 2005 · Class I recall1995200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants, 1 with a Class I recall12 generations forward: 2 descendants, 1 with a Class I recall13 generations forward: 1 descendant K051641 · Alaris System PC Unit, Model 8001 · Cardinal Health, Alaris Products · 2005 · Class I recallK950419 · The Imed Orion Infusion Pump and Administration Sets · Imed Corp. · 1995 · Class I recall0
  1. Root · 2 generations backK950419 The Imed Orion Infusion Pump and Administration SetsImed Corp. · 1995 · Recalled (Class I)
  2. 1 generation backK051641 Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products · 2005 · Recalled (Class I)
  3. This deviceK091308 Alaris PC Unit, Models 8000 and 8015Cardinal Health 303,Inc. · 2009
  4. Descendant · cites it directly · 3 of its ownK133532 Alaris System with Guardrails Suite MXCarefusion 303, Inc. · 2014 · Recalled (Class I)
  5. Descendant · 2 generations on · 1 of its ownK211218 BD Alaris System with Guardrails Suite MX v12.1.2Carefusion 303, Inc. · 2023 · Recalled (Class I)
  6. Descendant · 3 generations on · 0 of its ownK243855 BD Alaris Infusion System with Guardrails Suite MXCarefusion 303, Inc. · 2025
  7. Descendant · 2 generations on · 0 of its ownK210074 Agilia SP Infusion System, Agilia SP MC WIFI Infusion Pump, Agilia…Fresenius Kabi AG · 2022
  8. Descendant · cites it directly · 0 of its ownK110535 Alaris PC Unit Module 8000 with Software CorrectionCarefusion 303, Inc. · 2012

Class I recalls in this family

Most influential descendants

Showing 5 of 5 · See all
  • K133532Alaris System with Guardrails Suite MXCarefusion 303, Inc. · 2014 · cites it directly3descendants
  • K211218BD Alaris System with Guardrails Suite MX v12.1.2Carefusion 303, Inc. · 2023 · 2 generations on1descendant
  • K243855BD Alaris Infusion System with Guardrails Suite MXCarefusion 303, Inc. · 2025 · 3 generations on0descendants
  • K210074Agilia SP Infusion System, Agilia SP MC WIFI Infusion Pump, Agilia Link, Agilia Duo…Fresenius Kabi AG · 2022 · 2 generations on0descendants
  • K110535Alaris PC Unit Module 8000 with Software CorrectionCarefusion 303, Inc. · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K950419The Imed Orion Infusion Pump and Administration SetsImed Corp.1995Class I
−1K051641Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products2005Class I
0 (this device)K091308Alaris PC Unit, Models 8000 and 8015Cardinal Health 303,Inc.2009—
+1K133532Alaris System with Guardrails Suite MXCarefusion 303, Inc.2014Class I
+2K211218BD Alaris System with Guardrails Suite MX v12.1.2Carefusion 303, Inc.2023Class I
+3K243855BD Alaris Infusion System with Guardrails Suite MXCarefusion 303, Inc.2025—
+2K210074Agilia SP Infusion System, Agilia SP MC WIFI Infusion Pump, Agilia Link…Fresenius Kabi AG2022—
+1K110535Alaris PC Unit Module 8000 with Software CorrectionCarefusion 303, Inc.2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
201411
202210
202311
202510
FIG. 1 — Lineage of K091308, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

4 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K051641Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products2005Class I

Also cleared against K051641: 1 other device →

What descends from it? (5)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133532Alaris System with Guardrails Suite MX Class ICarefusion 303, Inc.20143
K110535Alaris PC Unit Module 8000 with Software CorrectionCarefusion 303, Inc.20120

Has anything in its family been recalled? (4 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K051641Alaris System PC Unit, Model 8001Cardinal Health, Alaris Products · 2005 · Direct predicate · ◆ on the line of descent in FIG. 110 Class I recalls
  • K950419The Imed Orion Infusion Pump and Administration SetsImed Corp. · 1995 · 2 generations back · ◆ on the line of descent in FIG. 14 Class I recalls
  • K133532Alaris System with Guardrails Suite MXCarefusion 303, Inc. · 2014 · Cites it directly · ◆ in the 2014 descendants bar of FIG. 128 Class I recalls
  • K211218BD Alaris System with Guardrails Suite MX v12.1.2Carefusion 303, Inc. · 2023 · 2 generations on · ◆ in the 2023 descendants bar of FIG. 17 Class I recalls

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 10.3 years on median.
  • 2 of the 2 ancestors have a recall of any class; 2 have a Class I recall.
  • Of its descendants, K133532 (Carefusion 303, Inc., 2014) has gone furthest, with 3 descendants of its own.
  • 1 other device also cites its predicate K051641.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The Alaris® PC Unit is the main user interface unit and power supply of the Alaris® System, a modular system to be used with Alaris® System modules (aka Medley TM System modules) intended for use in today's growing professional healthcare environment for facilities that utilize infusion and/or monitoring devices. The specific intended use for each Alaris® System module is specified in its respective submission.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K091308: Alaris PC Unit, Models 8000 and 8015.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K091308

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026