510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Artis Zee/Zeego SW VC21

K141574510(k) SpecialCleared Sep 5, 201485-day reviewClass II21 CFR 892.1650Recalls 12

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Medical Solutions USA, Inc. · OWB Interventional Fluoroscopic X-Ray System

Cleared on Sep 5, 2014 as substantially equivalent to K122644 (Siemens Medical Solutions USA, Inc., 2013) and 1 other predicate after an 85-day review. Its family tree reaches back 9 generations to 1980. 14 later devices descend from it. It has been recalled 12 times.

Decided
Sep 5, 2014
Review
85 days
Class
Class II
Product code
OWB
Recalls
12
Predicates
2

Its longest line of descent runs back 9 generations to K801623 (1980). 44 ancestors in all. 14 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2013: 1 other ancestor2002: 3 other ancestors2004: 2 other ancestors2001: 1 other ancestor2000: 3 other ancestors1995: 10 other ancestors1993: 2 other ancestors1989: 1 other ancestor1999: 1 other ancestor1997: 2 other ancestors1996: 3 other ancestors1994: 1 other ancestor1991: 3 other ancestors1992: 1 other ancestor1988: 1 other ancestor2018: 1 descendant cleared2024: 2 descendants cleared2022: 3 descendants cleared2020: 3 descendants cleared2019: 1 descendant cleared2026: 2 descendants cleared2023: 2 descendants clearedK801623 · Cavitron Ultrasonic Surg. Aspir. Cusa · Cavitron Corp. · 1980K962952 · Olympus Ultrasonic Surgical System (Usu) · Olympus Optical, Co. · 1996×2: 2 generations cleared close together, K972114 (1998), K981993 (1998) K994231 · Siemens Integrated Operating System (Sios) · Siemens Medical Corp. · 2000K052202 · Axiom Artis - Modular Angiographic System · Siemens Medical Solutions USA, Inc. · 2006 · recalledK073290 · Artis Zee and Zeego · Siemens Medical Solutions USA, Inc. · 2008 · recalledK090745 · Artis Zee / Zeegos with SW VC14 · Siemens Medical Solutions USA, Inc. · 2009 · recalledK123529 · Artis Q and Q.Zen- Modular Angiographic System · Siemens Medical Solutions USA, Inc. · 2013 · recalled19801990200020102020
  1. Root · 9 generations backK801623 Cavitron Ultrasonic Surg. Aspir. CusaCavitron Corp. · 1980
  2. 5 generations between
  3. 3 generations backK073290 Artis Zee and ZeegoSiemens Medical Solutions USA, Inc. · 2008 · Recalled
  4. 2 generations backK090745 Artis Zee / Zeegos with SW VC14Siemens Medical Solutions USA, Inc. · 2009 · Recalled
  5. 1 generation backK123529 Artis Q and Q.Zen- Modular Angiographic SystemSiemens Medical Solutions USA, Inc. · 2013 · Recalled
  6. This deviceK141574 Artis Zee/Zeego SW VC21Siemens Medical Solutions USA, Inc. · 2014
  7. Descendant · cites it directly · 13 of its ownK181407 Artis zee/zeego & Artis Q/Q.zenSiemens Medical Solution USA, Inc. · 2018 · Recalled
  8. Descendant · 2 generations on · 10 of its ownK190768 ARTIS iconoSiemens Medical Solutions USA, Inc. · 2019 · Recalled
  9. Descendant · 2 generations on · 5 of its ownK201156 ARTIS pheno (VE2)Siemens Medical Solution USA, Inc. · 2020 · Recalled
  10. Descendant · 3 generations on · 4 of its ownK220432 ARTIS icono (VE21) SystemSiemens Medical Solutions USA, Inc. · 2022 · Recalled
  11. Descendant · 3 generations on · 4 of its ownK220409 ARTIS pheno (VE21) SystemSiemens Medical Solutions USA, Inc. · 2022 · Recalled
Show all 9 generations
  1. Root · 9 generations backK801623 Cavitron Ultrasonic Surg. Aspir. CusaCavitron Corp. · 1980
  2. 8 generations backK962952 Olympus Ultrasonic Surgical System (Usu)Olympus Optical, Co. · 1996
  3. 7 generations backK972114 Olympus Sonosurg SystemThe Olympus Optical Co. · 1998
  4. 6 generations backK981993 Olympus Integrated Endosurgery System EndoalphaThe Olympus Optical Co. · 1998
  5. 5 generations backK994231 Siemens Integrated Operating System (Sios)Siemens Medical Corp. · 2000
  6. 4 generations backK052202 Axiom Artis - Modular Angiographic SystemSiemens Medical Solutions USA, Inc. · 2006 · Recalled
  7. 3 generations backK073290 Artis Zee and ZeegoSiemens Medical Solutions USA, Inc. · 2008 · Recalled
  8. 2 generations backK090745 Artis Zee / Zeegos with SW VC14Siemens Medical Solutions USA, Inc. · 2009 · Recalled
  9. 1 generation backK123529 Artis Q and Q.Zen- Modular Angiographic SystemSiemens Medical Solutions USA, Inc. · 2013 · Recalled
  10. This deviceK141574 Artis Zee/Zeego SW VC21Siemens Medical Solutions USA, Inc. · 2014

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2018: 12019: 12020: 32022: 32023: 22024: 22026: 2
2018high 3 (2020) · low 0 (2021)2026

Most influential descendants

Showing 5 of 14 · See all
  • K181407Artis zee/zeego & Artis Q/Q.zenSiemens Medical Solution USA, Inc. · 2018 · cites it directly13descendants
  • K190768ARTIS iconoSiemens Medical Solutions USA, Inc. · 2019 · 2 generations on10descendants
  • K201156ARTIS pheno (VE2)Siemens Medical Solution USA, Inc. · 2020 · 2 generations on5descendants
  • K220432ARTIS icono (VE21) SystemSiemens Medical Solutions USA, Inc. · 2022 · 3 generations on4descendants
  • K220409ARTIS pheno (VE21) SystemSiemens Medical Solutions USA, Inc. · 2022 · 3 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K801623Cavitron Ultrasonic Surg. Aspir. CusaCavitron Corp.1980—
−8K962952Olympus Ultrasonic Surgical System (Usu)Olympus Optical, Co.1996—
−7K972114Olympus Sonosurg SystemThe Olympus Optical Co.1998—
−6K981993Olympus Integrated Endosurgery System EndoalphaThe Olympus Optical Co.1998—
−5K994231Siemens Integrated Operating System (Sios)Siemens Medical Corp.2000—
−4K052202Axiom Artis - Modular Angiographic SystemSiemens Medical Solutions USA, Inc.200629
−3K073290Artis Zee and ZeegoSiemens Medical Solutions USA, Inc.200839
−2K090745Artis Zee / Zeegos with SW VC14Siemens Medical Solutions USA, Inc.20097
−1K123529Artis Q and Q.Zen- Modular Angiographic SystemSiemens Medical Solutions USA, Inc.201331
0 (this device)K141574Artis Zee/Zeego SW VC21Siemens Medical Solutions USA, Inc.2014—
+1K181407Artis zee/zeego & Artis Q/Q.zenSiemens Medical Solution USA, Inc.201859
+2K190768ARTIS iconoSiemens Medical Solutions USA, Inc.20194
+2K201156ARTIS pheno (VE2)Siemens Medical Solution USA, Inc.20206
+3K220432ARTIS icono (VE21) SystemSiemens Medical Solutions USA, Inc.20224
+3K220409ARTIS pheno (VE21) SystemSiemens Medical Solutions USA, Inc.20222

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
198910
199130
199210
199320
199410
1995100
199630
199720
199910
200030
200110
200230
200420
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
201910
202030
202230
202320
202420
202620
FIG. 1 — Lineage of K141574, 1980–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.3 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K122644Artis Zee/Zeego with CSX-10 Detector SW VC21
Summary page 5
…Response 2. Legally Marketed Primary Predicate Device Trade Name: Artis zee/zeego with CSX-10 Detector VC21 510(k) Clearance K122644 Clearance Date May 16, 2013 Classification Name: Image-Intensified Fluoroscopic X-ray System…
Siemens Medical Solutions USA, Inc.20131
*K123529Artis Q and Q.Zen- Modular Angiographic System
Summary page 5
…ry Predicate Device Trade Name: Artis Q and Q.zen – Modular Angiographic System 510(k) Clearance K123529 Clearance Date February 26, 2013 Classification Name: Image-Intensified Fluoroscopic X-ray System…
Siemens Medical Solutions USA, Inc.201331

Also cleared against K122644: 3 other devices →

What descends from it? (14)

See all 14

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K181407Artis zee/zeego & Artis Q/Q.zenSiemens Medical Solution USA, Inc.201813

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 25, 2018Class IIZ-2526-2018Process controlDue to a defective sealing, coolant may inflow into the electrical parts of the system cabinet, which could cause a short circuit and cause the system to shut down suddenly during an ongoing procedure
May 1, 2018Class IIZ-2311-2018Device DesignAfter the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure. If the problem…
May 1, 2018Class IIZ-2310-2018Device DesignAfter the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure. If the problem…
May 1, 2018Class IIZ-2314-2018Device DesignAfter the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure. If the problem…
May 1, 2018Class IIZ-2308-2018Device DesignAfter the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure. If the problem…
May 1, 2018Class IIZ-2309-2018Device DesignAfter the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure. If the problem…
May 1, 2018Class IIZ-2312-2018Device DesignAfter the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure. If the problem…
May 1, 2018Class IIZ-2313-2018Device DesignAfter the Large Display returns from power save mode, it may not show an image, and stay black without showing an error message although X-ray is still possible. The problem does not occur during an ongoing procedure. If the problem…
Sep 28, 2017Class IIZ-0710-2018Device DesignThe possibility exists for the wireless foot switch to fail due to impacts by external factors, such as electrostatic discharge that exceed a certain intensity. If the foot switch fails, it will no longer be able to be used to release…
Dec 8, 2016Class IIZ-0971-2017Software in the Use EnvironmentSiemens initiated a corrective action to address two possible, mutually independent causes of a system defect related to the following: - In Artis Systems with A100 Plus or A100G generators, an attempt to resume operation following…
Nov 1, 2016Class IIZ-0602-2017Software in the Use EnvironmentThe possibility exists that the semi-automatic focus switch may not work as intended when pressing the footswitch multiple times.
May 22, 2015Class IIZ-1846-2015Software designThere exists a possible position sensor fault in the swivel base axis not being detected by the system software. When moving, the system could potentially exceed its usual speed, resulting in a collision. No injuries reported.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 5 companies; a new generation was cleared every 1.9 years on median.
  • 10 of the 44 ancestors have a recall of any class.
  • Of its descendants, K181407 (Siemens Medical Solution USA, Inc., 2018) has gone furthest, with 13 descendants of its own.
  • 3 other devices also cite its predicate K122644.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

Artis zee / zeego is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Procedures that can be performed with the Artis zee / zeego family include cardiac angiography. neuro-angiography., general angiography, rotational angiography, multipurpose angiography and whole body radiographic/fluoroscopic procedures as well as…

Read the full statement (205 words)

Artis zee / zeego is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients.

Procedures that can be performed with the Artis zee / zeego family include cardiac angiography. neuro-angiography., general angiography, rotational angiography, multipurpose angiography and whole body radiographic/fluoroscopic procedures as well as procedures next to the table for i.e. patient extremities.

Additional procedures that can be performed include angiography in the operating room, image guided surgery by X-ray, by image fusion, and by navigation systems. The examination table as an integrated part of the system can be used for X-ray imaging, surgery and interventions.

Artis zee / zeego can also support the acquisition of position triggered imaging for spatial data synthesis.

The Artis zee and Artis zeego include also the software option DynaCT which identifies the Artis as a system with a C-arm CBCT functionality.

DynaCT is an x-ray imaging software option, which allows the reconstruction of two-dimensional images acquired with a standard angiographic C-arm device into a three-dimensional image format.

DynaCT is intended for imaging both hard and soft tissucs as well as other internal body structures for diagnosis, surgical planning, interventional procedures and treatment follow-up.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K141574: Artis Zee/Zeego SW VC21.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141574

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026