Recalled · Class II · 2025Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T, Optima MR450w 1.5T
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ge Medical Systems, LLC · LNH System, Nuclear Magnetic Resonance Imaging
Cleared on Jun 9, 2016 as substantially equivalent to K142085 (Ge Medical Systems, LLC, 2014) after a 98-day review. Its family tree reaches back 13 generations to 1997. 5 of the 47 devices in its family, counting itself, have a Class I recall. 16 later devices descend from it. It has been recalled 40 times.
- Decided
- Jun 9, 2016
- Review
- 98 days
- Class
- Class II
- Product code
- LNH
- Recalls
- 40
- Predicates
- 1
Its longest line of descent runs back 13 generations to K971684 (1997). 30 ancestors in all, the oldest K962061 (1996). 16 later devices descend from it, 1 citing it directly. 5 of the 47 devices in this family, counting this one, have a Class I recall.
- Root · 13 generations backK971684 Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc. · 1997 · Recalled
- 9 generations between
- 3 generations backK123522 Optima MR450WGe Healthcare (Ge Medical Systems, LLC) · 2013 · Recalled
- 2 generations backK132376 Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T…Ge Healthcare (Ge Medical Systems, LLC) · 2013 · Recalled
- 1 generation backK142085 Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750…Ge Medical Systems, LLC · 2014 · Recalled
- This deviceK160618 Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T…Ge Medical Systems, LLC · 2016
- Descendant · cites it directly · 15 of its ownK163331 Discovery MR750 3.0T; Discovery MR750w 3.0T;Discovery MR450 1.5T…Ge Medical Systems, LLC · 2017 · Recalled
- Descendant · 2 generations on · 11 of its ownK171128 SIGNA PremierGe Medical Systems, LLC · 2017 · Recalled
- Descendant · 3 generations on · 10 of its ownK183231 SIGNA PremierGe Medical Systems, LLC · 2019 · Recalled
- Descendant · 4 generations on · 9 of its ownK193282 SIGNA PremierGe Healthcare (Ge Medical Systems, LLC) · 2020 · Recalled
- Descendant · 5 generations on · 2 of its ownK213717 AIR Recon DLGe Medical Systems,Llc (Ge Healthcare) · 2022
Show all 13 generations
- Root · 13 generations backK971684 Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc. · 1997 · Recalled
- 12 generations backK032428 Magnetom Avanto MR SystemSiemens Medical Solutions USA, Inc. · 2003 · Recalled
- 11 generations backK041112 Magnetom Espree SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
- 10 generations backK052164 Magnetom Systems with Software Syngo MR 2006ASiemens Medical Solutions USA, Inc. · 2005
- 9 generations backK062454 Magnetom Systems - I-Class and T-Class ReleasesSiemens Medi Cal Solutions, Inc. · 2006
- 8 generations backK072237 Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · Recalled (Class I)
- 7 generations backK081028 Signa 3.0T MR750 SystemGe Medical Systems, LLC · 2008 · Recalled
- 6 generations backK083147 Discovery MR450Ge Medical Systems, LLC · 2008 · Recalled
- 5 generations backK091536 Optima MR450WGe Medical Systems, LLC · 2009 · Recalled
- 4 generations backK113490 Optima MR450WGe Medical Systems, LLC · 2012 · Recalled
- 3 generations backK123522 Optima MR450WGe Healthcare (Ge Medical Systems, LLC) · 2013 · Recalled
- 2 generations backK132376 Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T…Ge Healthcare (Ge Medical Systems, LLC) · 2013 · Recalled
- 1 generation backK142085 Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750…Ge Medical Systems, LLC · 2014 · Recalled
- This deviceK160618 Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T…Ge Medical Systems, LLC · 2016
Showing 5 of 16 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 16 · See all- K163331Discovery MR750 3.0T; Discovery MR750w 3.0T;Discovery MR450 1.5T; Discovery MR450w 1.5T…Ge Medical Systems, LLC · 2017 · cites it directly15descendants
- K171128SIGNA PremierGe Medical Systems, LLC · 2017 · 2 generations on11descendants
- K183231SIGNA PremierGe Medical Systems, LLC · 2019 · 3 generations on10descendants
- K193282SIGNA PremierGe Healthcare (Ge Medical Systems, LLC) · 2020 · 4 generations on9descendants
- K213717AIR Recon DLGe Medical Systems,Llc (Ge Healthcare) · 2022 · 5 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −13 | K971684 | Magnetom Project 047 System (Numaris 3.5 Software) | Siemens Medical Solutions USA, Inc. | 1997 | 4 |
| −12 | K032428 | Magnetom Avanto MR System | Siemens Medical Solutions USA, Inc. | 2003 | 4 |
| −11 | K041112 | Magnetom Espree System | Siemens Medical Solutions USA, Inc. | 2004 | 4 |
| −10 | K052164 | Magnetom Systems with Software Syngo MR 2006A | Siemens Medical Solutions USA, Inc. | 2005 | — |
| −9 | K062454 | Magnetom Systems - I-Class and T-Class Releases | Siemens Medi Cal Solutions, Inc. | 2006 | — |
| −8 | K072237 | Magnetom Verio | Siemens Medical Solutions USA, Inc. | 2007 | Class I |
| −7 | K081028 | Signa 3.0T MR750 System | Ge Medical Systems, LLC | 2008 | 11 |
| −6 | K083147 | Discovery MR450 | Ge Medical Systems, LLC | 2008 | 10 |
| −5 | K091536 | Optima MR450W | Ge Medical Systems, LLC | 2009 | 8 |
| −4 | K113490 | Optima MR450W | Ge Medical Systems, LLC | 2012 | 3 |
| −3 | K123522 | Optima MR450W | Ge Healthcare (Ge Medical Systems, LLC) | 2013 | 1 |
| −2 | K132376 | Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T, Optima… | Ge Healthcare (Ge Medical Systems, LLC) | 2013 | 15 |
| −1 | K142085 | Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750 3.0T,Optima MR450W… | Ge Medical Systems, LLC | 2014 | 27 |
| 0 (this device) | K160618 | Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T, Optima… | Ge Medical Systems, LLC | 2016 | — |
| +1 | K163331 | Discovery MR750 3.0T; Discovery MR750w 3.0T;Discovery MR450 1.5T; Discovery… | Ge Medical Systems, LLC | 2017 | 36 |
| +2 | K171128 | SIGNA Premier | Ge Medical Systems, LLC | 2017 | 8 |
| +3 | K183231 | SIGNA Premier | Ge Medical Systems, LLC | 2019 | 7 |
| +4 | K193282 | SIGNA Premier | Ge Healthcare (Ge Medical Systems, LLC) | 2020 | 7 |
| +5 | K213717 | AIR Recon DL | Ge Medical Systems,Llc (Ge Healthcare) | 2022 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 1 | 0 |
| 1998 | 1 | 0 |
| 1999 | 2 | 0 |
| 2001 | 4 | 1 |
| 2002 | 2 | 1 |
| 2003 | 1 | 1 |
| 2004 | 1 | 1 |
| 2005 | 3 | 0 |
| 2011 | 1 | 0 |
| 2013 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 2 | 0 |
| 2019 | 1 | 0 |
| 2020 | 4 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2024 | 1 | 0 |
| 2025 | 2 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
5 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LNH device
- #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K142085 | Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750 3.0T,Optima MR450W 1.5TSummary page 4…oduct Code: LNH Predicate Device(s): Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T, and Optima MR450w 1.5T [K142085] Device Description: The Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.… | 2014 |
What descends from it? (16)
See all 161 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K163331 | Discovery MR750 3.0T; Discovery MR750w 3.0T;Discovery MR450 1.5T; Discovery MR450w 1.5T… | 2017 | 15 |
Has anything in its family been recalled? (5 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jun 20, 2025 | Class II | Z-2306-2025 | Equipment maintenance | GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA… |
| Jun 20, 2025 | Class II | Z-2299-2025 | Equipment maintenance | GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA… |
| Jun 20, 2025 | Class II | Z-2302-2025 | Equipment maintenance | GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA… |
| Jun 20, 2025 | Class II | Z-2303-2025 | Equipment maintenance | GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA… |
| Jun 20, 2025 | Class II | Z-2301-2025 | Equipment maintenance | GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA… |
| May 23, 2025 | Class II | Z-2130-2025 | Device Design | GE HealthCare has become aware that gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. As a result, acoustic levels can exceed… |
| Oct 28, 2024 | Class II | Z-0517-2025 | Device Design | Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. |
| Oct 28, 2024 | Class II | Z-0518-2025 | Device Design | Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. |
| Oct 28, 2024 | Class II | Z-0519-2025 | Device Design | Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. |
| Jun 14, 2024 | Class II | Z-2464-2024 | Device Design | GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2… |
| Jun 14, 2024 | Class II | Z-2467-2024 | Device Design | GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2… |
| Jun 14, 2024 | Class II | Z-2465-2024 | Device Design | GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2… |
| Jun 14, 2024 | Class II | Z-2468-2024 | Device Design | GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2… |
| Jun 14, 2024 | Class II | Z-2469-2024 | Device Design | GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2… |
| Jun 14, 2024 | Class II | Z-2459-2024 | Device Design | GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2… |
| Dec 23, 2021 | Class II | Z-0600-2022 | Process control | The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. |
| Dec 23, 2021 | Class II | Z-0601-2022 | Process control | The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. |
| Dec 23, 2021 | Class II | Z-0591-2022 | Process control | The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. |
| Dec 23, 2021 | Class II | Z-0593-2022 | Process control | The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. |
| Dec 23, 2021 | Class II | Z-0594-2022 | Process control | The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. |
| Dec 23, 2021 | Class II | Z-0602-2022 | Process control | The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. |
| Aug 26, 2021 | Class II | Z-0135-2022 | Software design | Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images. |
| Aug 26, 2021 | Class II | Z-0136-2022 | Software design | Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images. |
| Aug 26, 2021 | Class II | Z-0133-2022 | Software design | Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images. |
| Aug 26, 2021 | Class II | Z-0139-2022 | Software design | Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images. |
| Aug 26, 2021 | Class II | Z-0140-2022 | Software design | Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images. |
| Jun 4, 2021 | Class II | Z-2061-2021 | Software design | GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed… |
| Jun 4, 2021 | Class II | Z-2056-2021 | Software design | GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed… |
| Jun 4, 2021 | Class II | Z-2053-2021 | Software design | GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed… |
| Jun 4, 2021 | Class II | Z-2055-2021 | Software design | GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed… |
| Jun 4, 2021 | Class II | Z-2063-2021 | Software design | GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed… |
| Jun 4, 2021 | Class II | Z-2064-2021 | Software design | GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed… |
| Sep 8, 2020 | Class II | Z-0129-2021 | Process change control | Potential electrical arc flash within the Power Gradient & RF (PGR) Cabinet. |
| Sep 8, 2020 | Class II | Z-0130-2021 | Process change control | Potential electrical arc flash within the Power Gradient & RF (PGR) Cabinet. |
| Oct 3, 2018 | Class II | Z-0236-2019 | Device Design | A small area on the bore surface, which is normally accessible to the patient, can get warm enough to cause a serious burn in the event the patient touches the bore and proper padding is not used. |
| May 11, 2017 | Class II | Z-3024-2017 | Mixed-up of materials/components | Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard. |
| May 11, 2017 | Class II | Z-3025-2017 | Mixed-up of materials/components | Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard. |
| May 11, 2017 | Class II | Z-3022-2017 | Mixed-up of materials/components | Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard. |
| May 11, 2017 | Class II | Z-3023-2017 | Mixed-up of materials/components | Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard. |
| Jan 20, 2017 | Class II | Z-1188-2017 | Device Design | Potential safety issue with the patient bore heating on the Discovery MR450 narrow bore 1.5T MRI. In the event of a RF component failure, typically happening after extended system use, a small area on the bore surface may become warmer… |
The 5 latest of 40 recalls; the web page lists all.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K072237Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · 6 generations back · ◆ on the line of descent in FIG. 11 Class I recall
- K041476GE Signa Excite 1.5T MR System, GE Signa Excite 3.0T MR SystemGe Medical Systems, LLC · 2004 · 7 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
- K030874GE 3.0T Signa Infinity Twinspeed with Excite MR SystemGeneral Electric Co. · 2003 · 8 generations back · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall
- K013636Signa Infinity MR System with Excite TechnologyGE Medical Systems · 2002 · 8 generations back · ◆ in the 2002 ancestors bar of FIG. 11 Class I recall
- K0122001.5T Infinity Twinspeed MR SystemGE Medical Systems · 2001 · 9 generations back · ◆ in the 2001 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 11 months on median.
- 23 of the 30 ancestors have a recall of any class; 5 have a Class I recall.
- Of its descendants, K163331 (Ge Medical Systems, LLC, 2017) has gone furthest, with 15 descendants of its own.
- 5 other devices also cite its predicate K142085.
How does its category compare?
All LNH devicesLNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · LNH
26in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LNH
122in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LNH
8in 2025
Class I (8 since 2007) Class II/III not classified
Adverse event reports per year · LNH
1,263in 2025
MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 35 | 25 | 114 |
| 2008 | 19 | 53 | 12 | 167 |
| 2009 | 17 | 70 | 7 | 194 |
| 2010 | 12 | 94 | 17 | 165 |
| 2011 | 16 | 81 | 11 | 182 |
| 2012 | 22 | 89 | 5 | 170 |
| 2013 | 19 | 108 | 2 | 107 |
| 2014 | 17 | 108 | 13 | 119 |
| 2015 | 19 | 140 | 12 (2) | 113 |
| 2016 | 20 | 108 | 1 | 135 |
| 2017 | 18 | 98 | 0 | 121 |
| 2018 | 29 | 128 | 71 | 158 |
| 2019 | 26 | 62 | 5 | 158 |
| 2020 | 32 | 121 | 4 | 98 |
| 2021 | 27 | 87 | 41 | 84 |
| 2022 | 30 | 74 | 13 | 138 |
| 2023 | 30 | 124 | 10 (1) | 159 |
| 2024 | 26 | 104 | 4 | 281 |
| 2025 | 26 | 122 | 8 (5) | 1,263 |
| 2026 | 24 | 126 | 43 | — |
What is it indicated for?
The Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T and the Optima MR450w 1.5T systems are whole body magnetic resonance scanners designed to support high resolution, high signal-to-noise ratio, and short scan times. It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and/or functions of the…
Read the full statement (154 words)
The Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T and the Optima MR450w 1.5T systems are whole body magnetic resonance scanners designed to support high resolution, high signal-to-noise ratio, and short scan times. It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and/or functions of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. Depending on the region of interest being imaged, contrast agents may be used.
The images produced by the Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T and the Optima MR450w 1.5T systems reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K160618 · printed Nov 5, 2026
Cite this page
510(k) Report. “K160618: Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T, Optima MR450w 1.5T.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K160618
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026