510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

SIGNAPioneer

K160621510(k) SpecialCleared Mar 29, 201625-day reviewClass II21 CFR 892.1000Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

GE Healthcare · LNH System, Nuclear Magnetic Resonance Imaging

Cleared on Mar 29, 2016 as substantially equivalent to K143345 (Ge Healthcare Japan Corporation, 2015) after a 25-day review. Its family tree reaches back 14 generations to 1997. 5 of the 41 devices in its family, counting itself, have a Class I recall. 9 later devices descend from it. It has been recalled 5 times.

Decided
Mar 29, 2016
Review
25 days
Class
Class II
Product code
LNH
Recalls
5
Predicates
1

Its longest line of descent runs back 14 generations to K971684 (1997). 31 ancestors in all, the oldest K962061 (1996). 9 later devices descend from it, 2 citing it directly. 5 of the 41 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2013: 1 other ancestor2011: 1 other ancestor2005: 3 other ancestors2004: 1 other ancestor, 1 with a Class I recall12003: 1 other ancestor, 1 with a Class I recall12002: 2 other ancestors, 1 with a Class I recall12001: 4 other ancestors, 1 with a Class I recall11999: 2 other ancestors1998: 1 other ancestor1996: 1 other ancestor2016: 1 descendant cleared2022: 1 descendant cleared2019: 2 descendants cleared2023: 3 descendants cleared2024: 1 descendant cleared2025: 1 descendant clearedK971684 · Magnetom Project 047 System (Numaris 3.5 Software) · Siemens Medical Solutions USA, Inc. · 1997 · recalledK032428 · Magnetom Avanto MR System · Siemens Medical Solutions USA, Inc. · 2003 · recalledK041112 · Magnetom Espree System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK052164 · Magnetom Systems with Software Syngo MR 2006A · Siemens Medical Solutions USA, Inc. · 2005K062454 · Magnetom Systems - I-Class and T-Class Releases · Siemens Medi Cal Solutions, Inc. · 2006K072237 · Magnetom Verio · Siemens Medical Solutions USA, Inc. · 2007 · Class I recallK081028 · Signa 3.0T MR750 System · Ge Medical Systems, LLC · 2008 · recalledK083147 · Discovery MR450 · Ge Medical Systems, LLC · 2008 · recalledK091536 · Optima MR450W · Ge Medical Systems, LLC · 2009 · recalledK113490 · Optima MR450W · Ge Medical Systems, LLC · 2012 · recalledK123522 · Optima MR450W · Ge Healthcare (Ge Medical Systems, LLC) · 2013 · recalledK132376 · Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T, Optima MR450W 1.5T · Ge Healthcare (Ge Medical Systems, LLC) · 2013 · recalledK142085 · Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750 3.0T,Optima MR450W 1.5T · Ge Medical Systems, LLC · 2014 · recalledK143345 · SIGNA Pioneer · Ge Healthcare Japan Corporation · 2015 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 4 generations back: 1 other ancestor5 generations back: 1 other ancestor7 generations back: 1 other ancestor8 generations back: 2 other ancestors, 1 with a Class I recall19 generations back: 4 other ancestors, 2 with a Class I recall210 generations back: 4 other ancestors, 1 with a Class I recall111 generations back: 4 other ancestors 1 generation forward: 2 descendants2 generations forward: 4 descendants3 generations forward: 3 descendants K143345 · SIGNA Pioneer · Ge Healthcare Japan Corporation · 2015 · recalledK142085 · Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750 3.0T,Optima MR450W 1.5T · Ge Medical Systems, LLC · 2014 · recalledK132376 · Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T, Optima MR450W 1.5T · Ge Healthcare (Ge Medical Systems, LLC) · 2013 · recalledK123522 · Optima MR450W · Ge Healthcare (Ge Medical Systems, LLC) · 2013 · recalledK113490 · Optima MR450W · Ge Medical Systems, LLC · 2012 · recalledK091536 · Optima MR450W · Ge Medical Systems, LLC · 2009 · recalledK083147 · Discovery MR450 · Ge Medical Systems, LLC · 2008 · recalledK081028 · Signa 3.0T MR750 System · Ge Medical Systems, LLC · 2008 · recalledK072237 · Magnetom Verio · Siemens Medical Solutions USA, Inc. · 2007 · Class I recallK062454 · Magnetom Systems - I-Class and T-Class Releases · Siemens Medi Cal Solutions, Inc. · 2006K052164 · Magnetom Systems with Software Syngo MR 2006A · Siemens Medical Solutions USA, Inc. · 2005K041112 · Magnetom Espree System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK032428 · Magnetom Avanto MR System · Siemens Medical Solutions USA, Inc. · 2003 · recalledK971684 · Magnetom Project 047 System (Numaris 3.5 Software) · Siemens Medical Solutions USA, Inc. · 1997 · recalled−10−50
  1. Root · 14 generations backK971684 Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc. · 1997 · Recalled
  2. 10 generations between
  3. 3 generations backK132376 Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T…Ge Healthcare (Ge Medical Systems, LLC) · 2013 · Recalled
  4. 2 generations backK142085 Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750…Ge Medical Systems, LLC · 2014 · Recalled
  5. 1 generation backK143345 SIGNA PioneerGe Healthcare Japan Corporation · 2015 · Recalled
  6. This deviceK160621 SIGNAPioneerGE Healthcare · 2016
  7. Descendant · cites it directly · 4 of its ownK161567 SIGNA VoyagerGE Healthcare · 2016 · Recalled
  8. Descendant · cites it directly · 3 of its ownK213668 SIGNA HeroGe Healthcare (Ge Medical Systems, LLC) · 2022 · Recalled
  9. Descendant · 2 generations on · 1 of its ownK223523 Sonic DLGe Medical Systems,Llc (Ge Healthcare) · 2023
  10. Descendant · 2 generations on · 1 of its ownK192426 Signa Voyager, Signa Voyager QuantumGe Healthcare (Tianjin) Company Limited · 2019 · Recalled
  11. Descendant · 2 generations on · 1 of its ownK183621 EMMA 1.5T MRI SystemTime Medical Limited · 2019
Show all 14 generations
  1. Root · 14 generations backK971684 Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc. · 1997 · Recalled
  2. 13 generations backK032428 Magnetom Avanto MR SystemSiemens Medical Solutions USA, Inc. · 2003 · Recalled
  3. 12 generations backK041112 Magnetom Espree SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
  4. 11 generations backK052164 Magnetom Systems with Software Syngo MR 2006ASiemens Medical Solutions USA, Inc. · 2005
  5. 10 generations backK062454 Magnetom Systems - I-Class and T-Class ReleasesSiemens Medi Cal Solutions, Inc. · 2006
  6. 9 generations backK072237 Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · Recalled (Class I)
  7. 8 generations backK081028 Signa 3.0T MR750 SystemGe Medical Systems, LLC · 2008 · Recalled
  8. 7 generations backK083147 Discovery MR450Ge Medical Systems, LLC · 2008 · Recalled
  9. 6 generations backK091536 Optima MR450WGe Medical Systems, LLC · 2009 · Recalled
  10. 5 generations backK113490 Optima MR450WGe Medical Systems, LLC · 2012 · Recalled
  11. 4 generations backK123522 Optima MR450WGe Healthcare (Ge Medical Systems, LLC) · 2013 · Recalled
  12. 3 generations backK132376 Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T…Ge Healthcare (Ge Medical Systems, LLC) · 2013 · Recalled
  13. 2 generations backK142085 Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750…Ge Medical Systems, LLC · 2014 · Recalled
  14. 1 generation backK143345 SIGNA PioneerGe Healthcare Japan Corporation · 2015 · Recalled
  15. This deviceK160621 SIGNAPioneerGE Healthcare · 2016

Showing 5 of 9 descendants. See all descendants

Descendants cleared per year

2016: 12019: 22022: 12023: 32024: 12025: 1
2016high 3 (2023) · low 0 (2017)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 9 · See all
  • K161567SIGNA VoyagerGE Healthcare · 2016 · cites it directly4descendants
  • K213668SIGNA HeroGe Healthcare (Ge Medical Systems, LLC) · 2022 · cites it directly3descendants
  • K223523Sonic DLGe Medical Systems,Llc (Ge Healthcare) · 2023 · 2 generations on1descendant
  • K192426Signa Voyager, Signa Voyager QuantumGe Healthcare (Tianjin) Company Limited · 2019 · 2 generations on1descendant
  • K183621EMMA 1.5T MRI SystemTime Medical Limited · 2019 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K971684Magnetom Project 047 System (Numaris 3.5 Software)Siemens Medical Solutions USA, Inc.19974
−13K032428Magnetom Avanto MR SystemSiemens Medical Solutions USA, Inc.20034
−12K041112Magnetom Espree SystemSiemens Medical Solutions USA, Inc.20044
−11K052164Magnetom Systems with Software Syngo MR 2006ASiemens Medical Solutions USA, Inc.2005—
−10K062454Magnetom Systems - I-Class and T-Class ReleasesSiemens Medi Cal Solutions, Inc.2006—
−9K072237Magnetom VerioSiemens Medical Solutions USA, Inc.2007Class I
−8K081028Signa 3.0T MR750 SystemGe Medical Systems, LLC200811
−7K083147Discovery MR450Ge Medical Systems, LLC200810
−6K091536Optima MR450WGe Medical Systems, LLC20098
−5K113490Optima MR450WGe Medical Systems, LLC20123
−4K123522Optima MR450WGe Healthcare (Ge Medical Systems, LLC)20131
−3K132376Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750W 3.0T, Optima…Ge Healthcare (Ge Medical Systems, LLC)201315
−2K142085Discovery MR750 3.0T ,Discovery MR450 1.5T, Discovery MR750 3.0T,Optima MR450W…Ge Medical Systems, LLC201427
−1K143345SIGNA PioneerGe Healthcare Japan Corporation20156
0 (this device)K160621SIGNAPioneerGE Healthcare2016—
+1K161567SIGNA VoyagerGE Healthcare20164
+1K213668SIGNA HeroGe Healthcare (Ge Medical Systems, LLC)20222
+2K223523Sonic DLGe Medical Systems,Llc (Ge Healthcare)2023—
+2K192426Signa Voyager, Signa Voyager QuantumGe Healthcare (Tianjin) Company Limited20194
+2K183621EMMA 1.5T MRI SystemTime Medical Limited2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
199810
199920
200141
200221
200311
200411
200530
201110
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201920
202210
202330
202410
202510
FIG. 1 — Lineage of K160621, 1997–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

5 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LNH device

  1. #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143345SIGNA Pioneer
Summary page 5
…Device Classification Names: Magnetic Resonance Diagnostic Device per 21 CFR 892.1000 Product Code: LNH Predicate Device: SIGNA Pioneer (K143345) Device Description: The SIGNA Pioneer features a 3.0T superconducting magnet with a 70cm…
Ge Healthcare Japan Corporation20156

Also cleared against K143345: 2 other devices →

What descends from it? (9)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K161567SIGNA VoyagerGE Healthcare20164
K213668SIGNA HeroGe Healthcare (Ge Medical Systems, LLC)20223

Has anything in its family been recalled? (5 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 14, 2024Class IIZ-2460-2024Device DesignGE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2…
Dec 23, 2021Class IIZ-0592-2022Process controlThe magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.
Aug 26, 2021Class IIZ-0134-2022Software designUnder certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images.
Jun 4, 2021Class IIZ-2054-2021Software designGE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed…
Dec 23, 2019Class IIZ-0876-2020Software designIt was identified that due to a potential installation workflow issue, the MR system date could be set incorrectly. The system's date and time setting are used to populate the DICOM header information on images. This could result is an…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K072237Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · 7 generations back · ◆ on the line of descent in FIG. 11 Class I recall
  • K041476GE Signa Excite 1.5T MR System, GE Signa Excite 3.0T MR SystemGe Medical Systems, LLC · 2004 · 8 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
  • K030874GE 3.0T Signa Infinity Twinspeed with Excite MR SystemGeneral Electric Co. · 2003 · 9 generations back · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall
  • K013636Signa Infinity MR System with Excite TechnologyGE Medical Systems · 2002 · 9 generations back · ◆ in the 2002 ancestors bar of FIG. 11 Class I recall
  • K0122001.5T Infinity Twinspeed MR SystemGE Medical Systems · 2001 · 10 generations back · ◆ in the 2001 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 19 years and passes through 6 companies; a new generation was cleared every 10 months on median.
  • 24 of the 31 ancestors have a recall of any class; 5 have a Class I recall.
  • Of its descendants, K161567 (GE Healthcare, 2016) has gone furthest, with 4 descendants of its own.
  • 2 other devices also cite its predicate K143345.

How does its category compare?

All LNH devices

LNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · LNH

26in 2025

2007: 122008: 192009: 172010: 122011: 162012: 222013: 192014: 172015: 192016: 202017: 182018: 292019: 262020: 322021: 272022: 302023: 302024: 262025: 262026 (partial year): 24
2007high 32 (2020) · low 12 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LNH

122in 2025

2007: 35 days median2008: 53 days median2009: 70 days median2010: 94 days median2011: 81 days median2012: 89 days median2013: 108 days median2014: 108 days median2015: 140 days median2016: 108 days median2017: 98 days median2018: 128 days median2019: 62 days median2020: 121 days median2021: 87 days median2022: 74 days median2023: 124 days median2024: 104 days median2025: 122 days median2026 (partial year): 126 days median
2007high 140 (2015) · low 35 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LNH

8in 2025

2007: 252008: 122009: 72010: 172011: 112012: 52013: 22014: 132015: 12, 2 Class I2016: 12018: 712019: 52020: 42021: 412022: 132023: 10, 1 Class I2024: 42025: 8, 5 Class I2026 (partial year): 43
2007high 71 (2018) · low 0 (2017)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · LNH

1,263in 2025

2007: 1142008: 1672009: 1942010: 1652011: 1822012: 1702013: 1072014: 1192015: 1132016: 1352017: 1212018: 1582019: 1582020: 982021: 842022: 1382023: 1592024: 2812025: 1,263
2007high 1,263 (2025) · low 84 (2021)2025

MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123525114
2008195312167
200917707194
2010129417165
2011168111182
201222895170
2013191082107
20141710813119
20151914012 (2)113
2016201081135
201718980121
20182912871158
201926625158
202032121498
202127874184
2022307413138
20233012410 (1)159
2024261044281
2025261228 (5)1,263
20262412643—

What is it indicated for?

The SIGNA Pioneer is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and/or functions of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart…

Read the full statement (129 words)

The SIGNA Pioneer is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times.

It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and/or functions of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body.

Depending on the region of interest being imaged, contrast agents may be used.

The images produced by the SIGNA Pioneer reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K160621: SIGNAPioneer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K160621

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026