510(k) Report

510(k) · Cleared

Recalled · Class I · 2025

Novum IQ Large Volume Pump

K211122510(k) TraditionalCleared Mar 29, 20241,079-day reviewClass II21 CFR 880.5725Recalls 3 (3 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corporation · FRN Pump, Infusion

Cleared on Mar 29, 2024 as substantially equivalent to K173084 (Baxter Healthcare Corporation, 2018) after a 1,079-day review. Its family tree reaches back 6 generations to 1990. 6 of the 11 devices in its family, counting itself, have a Class I recall. It has been recalled 3 times, including 3 Class I recalls.

Decided
Mar 29, 2024
Review
1,079 days
Class
Class II
Product code
FRN
Recalls
3 (3 Class I)
Predicates
1

Its longest line of descent runs back 6 generations to K904518 (1990). 10 ancestors in all. No later device cites it as a predicate yet. 6 of the 11 devices in this family, counting this one, have a Class I recall.

  1. Root · 6 generations backK904518 Volumetric Infusion PumpKendall Mcgaw Laboratories, Inc. · 1990 · Recalled
  2. 5 generations backK994375 Horizon LightB.Braun Medical, Inc. · 2000 · Recalled (Class I)
  3. 4 generations backK011975 Horizon Outlook with DosecomB.Braun Medical, Inc. · 2001 · Recalled (Class I)
  4. 3 generations backK042121 Spectrum and Spectrum with Master Drug LibrarySigma Intl. · 2004 · Recalled (Class I)
  5. 2 generations backK133801 Baxter Sigma Spectrum Infusion Pump with Master Drug LibraryBaxter Healthcare Corporation · 2014 · Recalled (Class I)
  6. 1 generation backK173084 Spectrum IQ Infusion System, Dose IQ Safety SoftwareBaxter Healthcare Corporation · 2018 · Recalled (Class I)
  7. This deviceK211122 Novum IQ Large Volume PumpBaxter Healthcare Corporation · 2024

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K904518Volumetric Infusion PumpKendall Mcgaw Laboratories, Inc.199037
−5K994375Horizon LightB.Braun Medical, Inc.2000Class I
−4K011975Horizon Outlook with DosecomB.Braun Medical, Inc.2001Class I
−3K042121Spectrum and Spectrum with Master Drug LibrarySigma Intl.2004Class I
−2K133801Baxter Sigma Spectrum Infusion Pump with Master Drug LibraryBaxter Healthcare Corporation2014Class I
−1K173084Spectrum IQ Infusion System, Dose IQ Safety SoftwareBaxter Healthcare Corporation2018Class I
0 (this device)K211122Novum IQ Large Volume PumpBaxter Healthcare Corporation2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199510
200010
200310
FIG. 1 — Lineage of K211122, 1990–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

6 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K173084Spectrum IQ Infusion System, Dose IQ Safety Software
Summary page 5
…21 CFR 880.5725 Regulation Name: Infusion Pump Regulatory Class: Class II Product Code: FRN PREDICATE DEVICE: Spectrum IQ Infusion System with Dose IQ Safety Software (K173084) DESCRIPTION OF THE DEVICE: The Novum IQ Large Volume Pump (LVP) is a large volumetric smart pump within the Novum IQ infusion p…
Baxter Healthcare Corporation2018Class I

Also cleared against K173084: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (6 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 4, 2025Class IZ-2332-2025Software design (manufacturing process)Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false…
Jul 14, 2025Class IZ-2173-2025Device DesignBaxter is issuing an Urgent Medical Device Correction for the Novum IQ large volume pump (LVP) due to the potential for underinfusion when transitioning from a flow rate to a higher flow rate that is more than double. (e.g., rate change…
Apr 24, 2025Class IZ-1767-2025Device DesignThere is a potential for the Novum IQ LVP due to the potential for underinfusion following use of the "standby mode" feature or if the device is powered off with the set loaded.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K173084Spectrum IQ Infusion System, Dose IQ Safety SoftwareBaxter Healthcare Corporation · 2018 · Direct predicate · ◆ on the line of descent in FIG. 14 Class I recalls
  • K133801Baxter Sigma Spectrum Infusion Pump with Master Drug LibraryBaxter Healthcare Corporation · 2014 · 2 generations back · ◆ on the line of descent in FIG. 15 Class I recalls
  • K042121Spectrum and Spectrum with Master Drug LibrarySigma Intl. · 2004 · 3 generations back · ◆ on the line of descent in FIG. 13 Class I recalls
  • K011975Horizon Outlook with DosecomB.Braun Medical, Inc. · 2001 · 4 generations back · ◆ on the line of descent in FIG. 11 Class I recall
  • K994375Horizon LightB.Braun Medical, Inc. · 2000 · 5 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 34 years and passes through 4 companies; a new generation was cleared every 5.9 years on median.
  • 7 of the 10 ancestors have a recall of any class; 5 have a Class I recall.
  • 4 other devices also cite its predicate K173084.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The Novum IQ Large Volume Pump (LVP) is intended for use on adults and pediatric subpopulations, except for neonates, for the controlled administration of fluids, pharmaceutical drugs, parenteral nutrition, blood and blood products through the following clinically accepted routes of administration: intravenous, arterial, subcutaneous and epidural. The Novum IQ LVP is intended for use on neonates, for the controlled administration of fluids and parenteral…

Read the full statement (182 words)

The Novum IQ Large Volume Pump (LVP) is intended for use on adults and pediatric subpopulations, except for

neonates, for the controlled administration of fluids, pharmaceutical drugs, parenteral nutrition, blood and blood products

through the following clinically accepted routes of administration: intravenous, arterial, subcutaneous and epidural.

The Novum IQ LVP is intended for use on neonates, for the controlled administration of fluids and parenteral nutrition

through the following clinically accepted routes of administration: intravenous and arterial.

The Novum IQ LVP is intended to be used in conjunction with legally marketed and compatible administration sets, and

medications provided by the user.

The Novum IQ LVP is suitable for patient care in hospitals and outpatient health care facilities.

The Novum IQ LVP is intended to aid in the reduction of operator interaction through guided programming, including a

way to automate the programming of infusion parameters and documentation of infusion therapies when integrated with

an Electronic Medical Record (EMR) system. This automation is intended to aid in the reduction of programming errors.

The Novum IQ LVP is intended to be used by trained healthcare professionals.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K211122: Novum IQ Large Volume Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K211122

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026