510(k) Report

510(k) · Cleared

Cleared

Biore CP-100 Cardiopulmonary Monitor

K900696510(k) TraditionalCleared Nov 29, 1990289-day reviewClass II21 CFR 868.1880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bicore Monitoring Systems · BZC Calculator, Pulmonary Function Data

Cleared on Nov 29, 1990 after a 289-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 41 of the 141 devices in its family, counting itself, have a Class I recall. 140 later devices descend from it.

Decided
Nov 29, 1990
Review
289 days
Class
Class II
Product code
BZC
Recalls
None
Predicates
0

140 later devices descend from it, 2 citing it directly. 41 of the 141 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2011: 13 descendants cleared, 7 with a Class I recall71998: 1 descendant cleared2023: 3 descendants cleared, 1 with a Class I recall12019: 8 descendants cleared, 3 with a Class I recall32002: 2 descendants cleared, 1 with a Class I recall12008: 8 descendants cleared, 1 with a Class I recall12012: 11 descendants cleared, 4 with a Class I recall42004: 2 descendants cleared2007: 3 descendants cleared, 1 with a Class I recall12025: 6 descendants cleared2006: 4 descendants cleared2005: 1 descendant cleared2014: 6 descendants cleared, 1 with a Class I recall12010: 5 descendants cleared, 1 with a Class I recall12009: 5 descendants cleared, 1 with a Class I recall12021: 7 descendants cleared, 3 with a Class I recall32015: 8 descendants cleared, 1 with a Class I recall12017: 11 descendants cleared, 5 with a Class I recall52013: 10 descendants cleared, 4 with a Class I recall42016: 8 descendants cleared, 3 with a Class I recall32024: 5 descendants cleared2018: 3 descendants cleared, 1 with a Class I recall12026: 5 descendants cleared2020: 4 descendants cleared, 3 with a Class I recall32022: 1 descendant cleared1990200020102020
  1. This deviceK900696 Biore CP-100 Cardiopulmonary MonitorBicore Monitoring Systems · 1990
  2. Descendant · cites it directly · 134 of its ownK983981 Bear 1000, Veolar W Leonardo Graphics, Bicore CP-2000, Bicore…Bear Medical Systems, Inc. · 1998
  3. Descendant · 2 generations on · 133 of its ownK013642 AVEABird Products Corp. · 2002 · Recalled (Class I)
  4. Descendant · 3 generations on · 114 of its ownK032451 Bird Tbird Vela VentilatorBird Products Corp. · 2004 · Recalled
  5. Descendant · 4 generations on · 112 of its ownK052554 Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005
  6. Descendant · 4 generations on · 87 of its ownK053270 IVENT 201Versamed Medical Systems, Inc. · 2006

Showing 5 of 140 descendants. See all descendants

Descendants cleared per year

1998: 12002: 22004: 22005: 12006: 42007: 32008: 82009: 52010: 52011: 132012: 112013: 102014: 62015: 82016: 82017: 112018: 32019: 82020: 42021: 72022: 12023: 32024: 52025: 62026: 5
1998high 13 (2011) · low 0 (1999)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 140 · See all
  • K983981Bear 1000, Veolar W Leonardo Graphics, Bicore CP-2000, Bicore CP-100, HI-LO Jet ET TubeBear Medical Systems, Inc. · 1998 · cites it directly134descendants
  • K013642AVEABird Products Corp. · 2002 · 2 generations on133descendants
  • K032451Bird Tbird Vela VentilatorBird Products Corp. · 2004 · 3 generations on114descendants
  • K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005 · 4 generations on112descendants
  • K053270IVENT 201Versamed Medical Systems, Inc. · 2006 · 4 generations on87descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K900696Biore CP-100 Cardiopulmonary MonitorBicore Monitoring Systems1990—
+1K983981Bear 1000, Veolar W Leonardo Graphics, Bicore CP-2000, Bicore CP-100, HI-LO…Bear Medical Systems, Inc.1998—
+2K013642AVEABird Products Corp.2002Class I
+3K032451Bird Tbird Vela VentilatorBird Products Corp.20041
+4K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2005—
+4K053270IVENT 201Versamed Medical Systems, Inc.2006—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199810
200221
200420
200510
200640
200731
200881
200951
201051
2011137
2012114
2013104
201461
201581
201683
2017115
201831
201983
202043
202173
202210
202331
202450
202560
202650
FIG. 1 — Lineage of K900696, 1990–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

41 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZC device

  1. #1 K240293 STSscore 9.8 · 7 generations · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (140)

See all 140

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K983981Bear 1000, Veolar W Leonardo Graphics, Bicore CP-2000, Bicore CP-100, HI-LO Jet ET TubeBear Medical Systems, Inc.1998134
K103578Philips NM3 Respiratory Monitor with VentassistRespironics Novametrix, LLC20114

Has anything in its family been recalled? (41 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K013642AVEABird Products Corp. · 2002 · 2 generations on · ◆ in the 2002 descendants bar of FIG. 113 Class I recalls
  • K070594Palmtop Ventilator, Models PTV-8, PTV-10Pulmonetic Systems, Inc. · 2007 · 4 generations on · ◆ in the 2007 descendants bar of FIG. 12 Class I recalls
  • K090888Newport HT70 Family of VentilatorsNewport Medical Instruments, Inc. · 2009 · 5 generations on · ◆ in the 2009 descendants bar of FIG. 13 Class I recalls
  • K093261MOVESThornhill Research, Inc. · 2010 · 5 generations on · ◆ in the 2010 descendants bar of FIG. 12 Class I recalls
  • K111146Newport HT70 VentilatorNewport Medical Instruments, Inc. · 2011 · 5 generations on · ◆ in the 2011 descendants bar of FIG. 14 Class I recalls
  • K162877VOCSN Unified Respiratory SystemVentec Life Systems, Inc. · 2017 · 5 generations on · ◆ in the 2017 descendants bar of FIG. 114 Class I recalls
  • K162832731 Series VentilatorsZOLL Medical Corporation · 2017 · 5 generations on · ◆ in the 2017 descendants bar of FIG. 11 Class I recall
  • K131774Hamilton-G5Hamilton Medical AG · 2013 · 5 generations on · ◆ in the 2013 descendants bar of FIG. 12 Class I recalls
  • K131252Puritan Bennett 980 Series Ventilator SystemCovidien · 2014 · 5 generations on · ◆ in the 2014 descendants bar of FIG. 13 Class I recalls
  • K072885Carina System, Model 8419350; Carina Basic Device, Model 5704110Draeger Medical AG & Co. KG · 2008 · 6 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
  • K111610Trilogy Series Ventilator with OximetryRespironics, Inc. · 2011 · 6 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
  • K103211Avea VentilatorCare Fusion · 2011 · 6 generations on · ◆ in the 2011 descendants bar of FIG. 114 Class I recalls

Nearest 12 of 41 shown.

What does this lineage say?

  • Of its descendants, K983981 (Bear Medical Systems, Inc., 1998) has gone furthest, with 134 descendants of its own.

How does its category compare?

All BZC devices

BZC Calculator, Pulmonary Function Data: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BZC

1in 2024

2007: 12011: 12014: 22015: 12016: 12017: 12018: 12019: 22024: 1
2007high 2 (2014) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZC

Too few BZC 510(k)s in any year since 2007 to give a median.

Recalls per year · BZC

3in 2009

2009: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · BZC

3in 2025

2007: 12008: 32016: 42017: 12018: 12019: 72020: 32021: 52022: 92023: 82024: 82025: 3
2007high 9 (2022) · low 0 (2009)2025

MAUDE reports naming product code BZC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—01
20080—03
20090—30
20100—00
20111—00
20120—00
20130—00
20142—00
20151—00
20161—04
20171—01
20181—01
20192—07
20200—03
20210—05
20220—09
20230—08
20241—08
20250—03
20260—0—
Cite this page

510(k) Report. “K900696: Biore CP-100 Cardiopulmonary Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K900696

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026