Neoflow Option Model Numbers 8413563, 8411900

K983219510(k) TraditionalCleared Dec 7, 199884-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Drager, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Dec 7, 1998 after an 84-day review. The FDA summary names its predicate without a number. 19 of the 54 devices in its family, counting itself, have a Class I recall. 53 later devices descend from it.

Decided
Dec 7, 1998
Review
84 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
0

53 later devices descend from it, 6 citing it directly. 19 of the 54 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2008: 3 descendants cleared, 1 with a Class I recall12011: 5 descendants cleared, 3 with a Class I recall32005: 2 descendants cleared2010: 3 descendants cleared, 1 with a Class I recall12006: 3 descendants cleared, 1 with a Class I recall12007: 3 descendants cleared2009: 2 descendants cleared2012: 6 descendants cleared, 2 with a Class I recall22023: 3 descendants cleared2013: 2 descendants cleared, 2 with a Class I recall22019: 3 descendants cleared, 1 with a Class I recall12015: 3 descendants cleared, 1 with a Class I recall12017: 3 descendants cleared, 2 with a Class I recall22016: 1 descendant cleared, 1 with a Class I recall12021: 2 descendants cleared, 1 with a Class I recall12020: 3 descendants cleared, 2 with a Class I recall22025: 2 descendants cleared2024: 2 descendants cleared2026: 1 descendant cleared2014: 1 descendant cleared, 1 with a Class I recall11995200020052010201520202025
  1. This deviceK983219 Neoflow Option Model Numbers 8413563, 8411900Drager, Inc. · 1998
  2. Descendant · cites it directly · 51 of its ownK051263 Evitaxl with Option SmartcareDrager Medical AG & Co. Kgaa · 2005 · Recalled
  3. Descendant · 2 generations on · 36 of its ownK061090 Galileo Gold AsvHamilton Medical AG · 2006
  4. Descendant · 3 generations on · 26 of its ownK070513 Hamilton-G5Hamilton Medical AG · 2007 · Recalled
  5. Descendant · 2 generations on · 23 of its ownK072412 Option Smartcare for Evitaxl,Smartcare Kit Capno Package, CO2 Sensor…Drager Medical AG & Co. Kgaa · 2008
  6. Descendant · 3 generations on · 21 of its ownK080181 Modification to Galileo GoldHamilton Medical AG · 2008

Showing 5 of 53 descendants. See all descendants

Descendants cleared per year

2005: 22006: 32007: 32008: 32009: 22010: 32011: 52012: 62013: 22014: 12015: 32016: 12017: 32019: 32020: 32021: 22023: 32024: 22025: 22026: 1
2005high 6 (2012) · low 0 (2018)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 53 · See all
  • K051263Evitaxl with Option SmartcareDrager Medical AG & Co. Kgaa · 2005 · cites it directly51descendants
  • K061090Galileo Gold AsvHamilton Medical AG · 2006 · 2 generations on36descendants
  • K070513Hamilton-G5Hamilton Medical AG · 2007 · 3 generations on26descendants
  • K072412Option Smartcare for Evitaxl,Smartcare Kit Capno Package, CO2 Sensor Capnosmart, Models…Drager Medical AG & Co. Kgaa · 2008 · 2 generations on23descendants
  • K080181Modification to Galileo GoldHamilton Medical AG · 2008 · 3 generations on21descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K983219Neoflow Option Model Numbers 8413563, 8411900Drager, Inc.1998—
+1K051263Evitaxl with Option SmartcareDrager Medical AG & Co. Kgaa20051
+2K061090Galileo Gold AsvHamilton Medical AG2006—
+3K070513Hamilton-G5Hamilton Medical AG20071
+2K072412Option Smartcare for Evitaxl,Smartcare Kit Capno Package, CO2 Sensor…Drager Medical AG & Co. Kgaa2008—
+3K080181Modification to Galileo GoldHamilton Medical AG2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200520
200631
200730
200831
200920
201031
201153
201262
201322
201411
201531
201611
201732
201931
202032
202121
202330
202420
202520
202610
FIG. 1 — Lineage of K983219, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

19 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Evita 4
Named without a submission number
—
*—Babylog 8000 plus
Named without a submission number
—
*—Servo 300
Named without a submission number
—

What descends from it? (53)

See all 53

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K051263Evitaxl with Option SmartcareDrager Medical AG & Co. Kgaa200551
K081521Modification to Hamilton-G5 Class IHamilton Medical AG200816
K103803Hamilton-G5 Class IHamilton Medical AG201114
K102775Hamilton-C2Hamilton Medical AG201114
K093632Infinity Acute Care System Workstation Neonatal Care Class IDrager Medical AG & Co. Kgaa201010
K051262Esprit Ventilator Neonatal Option, Model V1000Respironics California, Inc.20050

Has anything in its family been recalled? (19 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K081521Modification to Hamilton-G5Hamilton Medical AG · 2008 · Cites it directly · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
  • K103803Hamilton-G5Hamilton Medical AG · 2011 · Cites it directly · ◆ in the 2011 descendants bar of FIG. 11 Class I recall
  • K093632Infinity Acute Care System Workstation Neonatal CareDrager Medical AG & Co. Kgaa · 2010 · Cites it directly · ◆ in the 2010 descendants bar of FIG. 14 Class I recalls
  • K053388Model 840 Ventilator with Proportional Assist Ventilation Plus Software OptionPuritan Bennett Corp. · 2006 · 2 generations on · ◆ in the 2006 descendants bar of FIG. 11 Class I recall
  • K121225Hamilton-C2Hamilton Medical AG · 2012 · 2 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K130178Inspiration Ventilator System 5I/7IeVent Medical, Ltd. · 2013 · 2 generations on · ◆ in the 2013 descendants bar of FIG. 11 Class I recall
  • K131774Hamilton-G5Hamilton Medical AG · 2013 · 2 generations on · ◆ in the 2013 descendants bar of FIG. 12 Class I recalls
  • K120670Hamilton-T1Hamilton Medical AG · 2012 · 3 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K111116Engstrom Carestation, Engstrom Pro, Models 1505-9000-000, 1505-9003-000Datex-Ohmeda · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 13 Class I recalls
  • K162832731 Series VentilatorsZOLL Medical Corporation · 2017 · 4 generations on · ◆ in the 2017 descendants bar of FIG. 11 Class I recall
  • K181216Hamilton-T1, Hamilton-C1Hamilton Medical AG · 2019 · 4 generations on · ◆ in the 2019 descendants bar of FIG. 15 Class I recalls
  • K153046Hamilton-MR1Hamilton Medical AG · 2016 · 4 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall

Nearest 12 of 19 shown.

What does this lineage say?

  • Of its descendants, K051263 (Drager Medical AG & Co. Kgaa, 2005) has gone furthest, with 51 descendants of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The Evita 4 / 2 Dura with NeoFlow Option is a long-term ventilator to be used for intensive care and inner clinical transport of adults, children, infants and neonates with a minimum body weight of 0.5 kg. The device is microprocessor controlled and provides the following ventilation modes: - CMVl/assist Controlled Mandatory Ventiiation Controlled and assisted volume constant ventilation, with the options: - CPPV Continuous Positive Pressure Ventilation…

Read the full statement (245 words)

The Evita 4 / 2 Dura with NeoFlow Option is a long-term ventilator to be used for intensive care and inner clinical transport of adults, children, infants and neonates with a minimum body weight of 0.5 kg.

The device is microprocessor controlled and provides the following ventilation modes:

- CMVl/assist Controlled Mandatory Ventiiation

Controlled and assisted volume constant ventilation, with the options:

- CPPV Continuous Positive Pressure Ventilation

- PLV Pressure Limited Ventilation

- AutoFlow For automatic regulation of inspiratory flow

- IRV Inversed Ratio Ventilation

- SiMV Synchronised Intermittent Mandatory Ventilation

Procedure for weaning patients off the ventilator after they have started spontaneous breathing. With the options:

- PLV

- AutoFlow

- MMV Mandatory Minute Volume Ventilation

Spontaneous breathing with automatic adjustment of mandatory ventilation to the patients minute volume requirement. With the options:

- PLV

- AutoFlow

- SB Spontaneous Breathing

Spontaneous breathing at ambient pressure

- CPAP Continuos Positive Airway Pressure

Spontaneous breathing with positive airway pressure

- ASBIPSV Assisted Spontaneous Breathing / Pressure Support Ventilation

Pressure supported spantaneous breathing

- PCV+ Pressure controlled ventilation, combined with free spontaneous breathing during the complete breathing cycle, and adjustable pressure increase to CPAP level

- APRV Alrway Pressure Release Ventilation

Spontaneous breathing on two pressure levels with long time ranges - independently adjustable.

- Apnea Ventilation For switching over automatically to volume controlled ventilation if breathing stops.

- Independent Lung Ventilation

Separate, differentiated synchronised ventilation with one Evita 4 / 2 Dura for each

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K983219: Neoflow Option Model Numbers 8413563, 8411900.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K983219

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026