Drager Oxylog 2000

K984577510(k) SpecialCleared Jan 22, 199930-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Drager, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Jan 22, 1999 after a 30-day review. The FDA summary names its predicate without a number. 11 of the 22 devices in its family, counting itself, have a Class I recall. 21 later devices descend from it.

Decided
Jan 22, 1999
Review
30 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
0

21 later devices descend from it, 3 citing it directly. 11 of the 22 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2008: 1 descendant cleared, 1 with a Class I recall12011: 1 descendant cleared, 1 with a Class I recall12006: 1 descendant cleared, 1 with a Class I recall12015: 2 descendants cleared, 1 with a Class I recall12012: 5 descendants cleared, 2 with a Class I recall22014: 1 descendant cleared2019: 2 descendants cleared, 1 with a Class I recall12016: 1 descendant cleared, 1 with a Class I recall12023: 1 descendant cleared2017: 2 descendants cleared, 1 with a Class I recall12024: 1 descendant cleared2021: 1 descendant cleared, 1 with a Class I recall12020: 1 descendant cleared, 1 with a Class I recall12026: 1 descendant cleared1995200020052010201520202025
  1. This deviceK984577 Drager Oxylog 2000Drager, Inc. · 1999
  2. Descendant · cites it directly · 20 of its ownK062267 Oxylog 3000Drager Medical B.V. · 2006 · Recalled (Class I)
  3. Descendant · 2 generations on · 13 of its ownK112006 Hamilton-TC1Hamilton Medical AG · 2012
  4. Descendant · 3 generations on · 11 of its ownK120670 Hamilton-T1Hamilton Medical AG · 2012 · Recalled (Class I)
  5. Descendant · 4 generations on · 8 of its ownK121225 Hamilton-C2Hamilton Medical AG · 2012 · Recalled (Class I)
  6. Descendant · 5 generations on · 4 of its ownK123637 Hamilton-C3Hamilton Medical AG · 2012

Showing 5 of 21 descendants. See all descendants

Descendants cleared per year

2006: 12008: 12011: 12012: 52014: 12015: 22016: 12017: 22019: 22020: 12021: 12023: 12024: 12026: 1
2006high 5 (2012) · low 0 (2007)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 21 · See all
  • K062267Oxylog 3000Drager Medical B.V. · 2006 · cites it directly20descendants
  • K112006Hamilton-TC1Hamilton Medical AG · 2012 · 2 generations on13descendants
  • K120670Hamilton-T1Hamilton Medical AG · 2012 · 3 generations on11descendants
  • K121225Hamilton-C2Hamilton Medical AG · 2012 · 4 generations on8descendants
  • K123637Hamilton-C3Hamilton Medical AG · 2012 · 5 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K984577Drager Oxylog 2000Drager, Inc.1999—
+1K062267Oxylog 3000Drager Medical B.V.2006Class I
+2K112006Hamilton-TC1Hamilton Medical AG2012—
+3K120670Hamilton-T1Hamilton Medical AG2012Class I
+4K121225Hamilton-C2Hamilton Medical AG2012Class I
+5K123637Hamilton-C3Hamilton Medical AG2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200611
200811
201111
201252
201410
201521
201611
201721
201921
202011
202111
202310
202410
202610
FIG. 1 — Lineage of K984577, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

11 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Oxylog 2000
Named without a submission number
—

What descends from it? (21)

See all 21

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K062267Oxylog 3000 Class IDrager Medical B.V.200620
K082600Oxylog 2000 Plus System (Model 5705080), Oxylog 2000 Plus Basic Device (Model 5705082) Class IDraeger Medical B.V.20083
K103625Oxylog 3000 Plus Workstation, Oxylog 3000 Plus Basic Device Class IDraeger Medical Systems, Inc.20112

Has anything in its family been recalled? (11 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K082600Oxylog 2000 Plus System (Model 5705080), Oxylog 2000 Plus Basic Device (Model 5705082)Draeger Medical B.V. · 2008 · Cites it directly · ◆ in the 2008 descendants bar of FIG. 12 Class I recalls
  • K103625Oxylog 3000 Plus Workstation, Oxylog 3000 Plus Basic DeviceDraeger Medical Systems, Inc. · 2011 · Cites it directly · ◆ in the 2011 descendants bar of FIG. 14 Class I recalls
  • K062267Oxylog 3000Drager Medical B.V. · 2006 · Cites it directly · ◆ in the 2006 descendants bar of FIG. 13 Class I recalls
  • K141595O-Two E700,O-Two E600,O-Two E500O-Two Medical Technologies, Inc. · 2015 · 2 generations on · ◆ in the 2015 descendants bar of FIG. 13 Class I recalls
  • K120670Hamilton-T1Hamilton Medical AG · 2012 · 3 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K181216Hamilton-T1, Hamilton-C1Hamilton Medical AG · 2019 · 3 generations on · ◆ in the 2019 descendants bar of FIG. 15 Class I recalls
  • K153046Hamilton-MR1Hamilton Medical AG · 2016 · 3 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall
  • K121225Hamilton-C2Hamilton Medical AG · 2012 · 4 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K162832731 Series VentilatorsZOLL Medical Corporation · 2017 · 4 generations on · ◆ in the 2017 descendants bar of FIG. 11 Class I recall
  • K201306Hamilton-C3Hamilton Medical AG · 2021 · 7 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall
  • K201658Hamilton-C6Hamilton Medical AG · 2020 · 7 generations on · ◆ in the 2020 descendants bar of FIG. 13 Class I recalls

What does this lineage say?

  • Of its descendants, K062267 (Drager Medical B.V., 2006) has gone furthest, with 20 descendants of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The Oxylog 2000 is a time cycled, volume constant transport and emergency ventilator for patients with tidal volumes starting at 100 mL.

With applications in:

mobile emergency and primary care of emergency patients

patient transports in emergency rescue vehicles or by helicopter

patient transfers by road or air

inner hospital transport of ventilated patients

emergency room

secondary transports between hospitals

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K984577: Drager Oxylog 2000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K984577

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026