510(k) · Cleared
Recalled · Class II · 2016Neuviz 16 Multi-Slice CT Scanner System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Neusoft Medical Systems Co., Ltd. · JAK System, X-Ray, Tomography, Computed
Cleared on Feb 5, 2009 as substantially equivalent to K012009 (Marconi Medical Systems, Inc., 2001) after a 13-day review. Its family tree reaches back 4 generations to 1993. It has been recalled 5 times.
- Decided
- Feb 5, 2009
- Review
- 13 days
- Class
- Class II
- Product code
- JAK
- Recalls
- 5
- Predicates
- 1
Its longest line of descent runs back 4 generations to K930090 (1993). 9 ancestors in all. No later device cites it as a predicate yet.
- Root · 4 generations backK930090 HelicatElscint, Inc. · 1993
- 3 generations backK961464 Select/SPElscint, Inc. · 1996 · Recalled
- 2 generations backK982060 Volumax CT Imaging SystemElscint, Inc. · 1998
- 1 generation backK012009 MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · Recalled
- This deviceK090173 Neuviz 16 Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd. · 2009
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K930090 | Helicat | Elscint, Inc. | 1993 | — |
| −3 | K961464 | Select/SP | Elscint, Inc. | 1996 | 3 |
| −2 | K982060 | Volumax CT Imaging System | Elscint, Inc. | 1998 | — |
| −1 | K012009 | MX8000 Idt CT System | Marconi Medical Systems, Inc. | 2001 | 61 |
| 0 (this device) | K090173 | Neuviz 16 Multi-Slice CT Scanner System | Neusoft Medical Systems Co., Ltd. | 2009 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 2 | 0 |
| 1995 | 1 | 0 |
| 1997 | 1 | 0 |
| 2001 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K012009 | MX8000 Idt CT SystemSummary page 3…and operating principle as Phillips existing marketed product, Brilliance CT16 Scanner System. Predicated Device: Phillips brilliance CT16 Scanner System (K012009) Statement of Substantial Equivalence: The NeuViz 16 Multi-slice CT Scanner System is of comparable type and subst… | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Mar 24, 2016 | Class II | Z-1573-2016 | Under Investigation by firm | The following issues are found in NeuViz 16 systems with software version 1.1.4.21425 and version 1.1.4.21426: 1) During the filming operation on MX 16-slice console software, the clipboard used for copying and pasting images is not… |
| Mar 4, 2013 | Class II | Z-1165-2013 | Use error | User error of the NeuViz 16 or NeuViz Dual may cause personnel injuries. There was a report where a finger was pinched when the table was moved backward while the tabletop was controlled by another person from the gantry left control panel. |
| Oct 18, 2012 | Class II | Z-0466-2013 | Device Design | The four screws that secure the patient table top to the carrier pulled out and caused the table top to detach. This issue may affect NeuViz Dual and NeuViz 16 scanners. |
| Jun 8, 2012 | Class II | Z-2083-2012 | Device Design | One of the four screws that secure the Oil-accumulator to the X-Ray Tube pulled out in the NeuViz 16 CT scanner, which caused the Oil-accumulator to detach. |
| Feb 9, 2011 | Not classified | Z-2241-2011 | Other | Dimension measurement displays on a combined image were found inaccurate after the clinician merged multiple image series into one image. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 16 years and passes through 3 companies; a new generation was cleared every 3.3 years on median.
- 3 of the 9 ancestors have a recall of any class.
- 10 other devices also cite its predicate K012009.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
The NeuViz 16 Multi-Slice CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and detector array with multislice capability up to 16 slices simultaneously. The acquired X-RAY transmission data is reconstructed by computer into cross-sectional imagers of the body from the same axial plane taken at different angles. The system is suitable for all patients.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K090173 · printed Nov 6, 2026
Cite this page
510(k) Report. “K090173: Neuviz 16 Multi-Slice CT Scanner System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K090173
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026