510(k) Report

510(k) · Cleared

Recalled · Class II · 2026

uCT Computed Tomography X-ray System

K172135510(k) TraditionalCleared Mar 2, 2018231-day reviewClass II21 CFR 892.1750Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shanghai United Imaging Healthcare Co., Ltd. · JAK System, X-Ray, Tomography, Computed

Cleared on Mar 2, 2018 as substantially equivalent to K033326 (Philips Medical Systems, Inc., 2003) after a 231-day review. Its family tree reaches back 5 generations to 1993. 12 later devices descend from it. It has been recalled 7 times.

Decided
Mar 2, 2018
Review
231 days
Class
Class II
Product code
JAK
Recalls
7
Predicates
1

Its longest line of descent runs back 5 generations to K930090 (1993). 10 ancestors in all. 12 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1997: 1 other ancestor1995: 1 other ancestor1994: 2 other ancestors2018: 1 descendant cleared2023: 3 descendants cleared2020: 2 descendants cleared2021: 1 descendant cleared2019: 1 descendant cleared2025: 3 descendants cleared2026: 1 descendant clearedK930090 · Helicat · Elscint, Inc. · 1993K961464 · Select/SP · Elscint, Inc. · 1996 · recalledK982060 · Volumax CT Imaging System · Elscint, Inc. · 1998K012009 · MX8000 Idt CT System · Marconi Medical Systems, Inc. · 2001 · recalledK033326 · Philips Plus Computed Tomography System · Philips Medical Systems, Inc. · 2003 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor4 generations back: 3 other ancestors5 generations back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 5 descendants3 generations forward: 2 descendants K033326 · Philips Plus Computed Tomography System · Philips Medical Systems, Inc. · 2003 · recalledK012009 · MX8000 Idt CT System · Marconi Medical Systems, Inc. · 2001 · recalledK982060 · Volumax CT Imaging System · Elscint, Inc. · 1998K961464 · Select/SP · Elscint, Inc. · 1996 · recalledK930090 · Helicat · Elscint, Inc. · 1993−50
  1. Root · 5 generations backK930090 HelicatElscint, Inc. · 1993
  2. 4 generations backK961464 Select/SPElscint, Inc. · 1996 · Recalled
  3. 3 generations backK982060 Volumax CT Imaging SystemElscint, Inc. · 1998
  4. 2 generations backK012009 MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · Recalled
  5. 1 generation backK033326 Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc. · 2003 · Recalled
  6. This deviceK172135 uCT Computed Tomography X-ray SystemShanghai United Imaging Healthcare Co., Ltd. · 2018
  7. Descendant · cites it directly · 6 of its ownK203448 uCT ATLAS with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd. · 2021 · Recalled
  8. Descendant · cites it directly · 3 of its ownK181414 uCT 530, uCT 550Shanghai United Imaging Healthcare Co., Ltd. · 2018 · Recalled
  9. Descendant · cites it directly · 2 of its ownK230162 uCT 760 with uWS-CT-Dual Energy Analysis, uCT 780 with uWS-CT-Dual…Shanghai United Imaging Healthcare Co., Ltd. · 2023 · Recalled
  10. Descendant · 2 generations on · 2 of its ownK223028 uCT ATLAS Astound with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd. · 2023
  11. Descendant · 2 generations on · 1 of its ownK241079 uCT 780Shanghai United Imaging Healthcare Co., Ltd. · 2025 · Recalled

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

2018: 12019: 12020: 22021: 12023: 32025: 32026: 1
2018high 3 (2023) · low 0 (2022)2026

Most influential descendants

Showing 5 of 12 · See all
  • K203448uCT ATLAS with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd. · 2021 · cites it directly6descendants
  • K181414uCT 530, uCT 550Shanghai United Imaging Healthcare Co., Ltd. · 2018 · cites it directly3descendants
  • K230162uCT 760 with uWS-CT-Dual Energy Analysis, uCT 780 with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd. · 2023 · cites it directly2descendants
  • K223028uCT ATLAS Astound with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd. · 2023 · 2 generations on2descendants
  • K241079uCT 780Shanghai United Imaging Healthcare Co., Ltd. · 2025 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K930090HelicatElscint, Inc.1993—
−4K961464Select/SPElscint, Inc.19963
−3K982060Volumax CT Imaging SystemElscint, Inc.1998—
−2K012009MX8000 Idt CT SystemMarconi Medical Systems, Inc.200161
−1K033326Philips Plus Computed Tomography SystemPhilips Medical Systems, Inc.2003131
0 (this device)K172135uCT Computed Tomography X-ray SystemShanghai United Imaging Healthcare Co., Ltd.2018—
+1K203448uCT ATLAS with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd.20213
+1K181414uCT 530, uCT 550Shanghai United Imaging Healthcare Co., Ltd.201810
+1K230162uCT 760 with uWS-CT-Dual Energy Analysis, uCT 780 with uWS-CT-Dual Energy…Shanghai United Imaging Healthcare Co., Ltd.20234
+2K223028uCT ATLAS Astound with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd.2023—
+2K241079uCT 780Shanghai United Imaging Healthcare Co., Ltd.20252

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199510
199710
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
201910
202020
202110
202330
202530
202610
FIG. 1 — Lineage of K172135, 1993–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K033326Philips Plus Computed Tomography System
Summary page 5
…tem Regulatory Class: II Product Code: JAK Review Panel: Radiology 4. Identification of Predicate Device(s) Predicate Device 510(k) Number: K033326 Device Name: “Philips Plus” CT scanner Model(s): Brilliance 40, Brilliance 64 Regulatory Information Regulat…
Philips Medical Systems, Inc.2003131

Also cleared against K033326: 8 other devices →

What descends from it? (12)

See all 12

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K203448uCT ATLAS with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd.20216
K181414uCT 530, uCT 550Shanghai United Imaging Healthcare Co., Ltd.20183
K230162uCT 760 with uWS-CT-Dual Energy Analysis, uCT 780 with uWS-CT-Dual Energy AnalysisShanghai United Imaging Healthcare Co., Ltd.20232
K200016uCT 530, uCT 550Shanghai United Imaging Healthcare Co., Ltd.20201
K193073Deep ReconShanghai United Imaging Healthcare Co., Ltd.20200

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 11, 2026Class IIZ-3279-2026Software designPositron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on…
Aug 11, 2026Class IIZ-3280-2026Software designPositron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on…
Sep 12, 2025Class IIZ-0219-2026OtherThird-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.
Sep 12, 2025Class IIZ-0220-2026OtherThird-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.
Aug 5, 2020Class IIZ-0447-2021Software designA potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.
Jun 20, 2020Class IIZ-2703-2020Device DesignThe metal edge overlap of the mylar strip in the gantry was uneven, which may create a sharp edge.
May 8, 2020Class IIZ-2522-2020Software designTwo issues were identified with the computed tomography x-ray system including an intermittent issue which may affect image data leading to artifacts; and intermittent scout scanning interruption due to occasional angle signal drift. This…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 3.0 years on median.
  • 4 of the 10 ancestors have a recall of any class.
  • Of its descendants, K203448 (Shanghai United Imaging Healthcare Co., Ltd., 2021) has gone furthest, with 6 descendants of its own.
  • 8 other devices also cite its predicate K033326.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

uCT 760/780 is a computed tomography x-ray system intended to produce cross-sectional images of the body by

computer reconstruction of x-ray transmission data taken at different angles and planes and indicated for the whole body

(including head, neck, cardiac and vascular).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172135: uCT Computed Tomography X-ray System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172135

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026